A rapid highly-sensitive endotoxin detection system.

This paper presents a rapid, highly-sensitive, and low-cost method of endotoxin quantification based on the use of stress-responsive magnetoelastic sensors, that monitor the gel formation (viscosity change) of the Limulus Amoebocyte Lysate (LAL) assay in response to endotoxin. Ribbon-like magnetoelastic sensors, 12.7 mm x 6 mm x 28 microm, were immersed in a LAL assay after mixing with test samples of variable endotoxin concentration, and the decrease in resonance amplitude of the sensor was recorded as a function of time. Experimental results show excellent correlation between endotoxin concentration and the maximum clot rate, determined by taking the minimum point of the first derivative of the amplitude-time curve, as well as the clotting-time, defined as the time that corresponds to the maximum clot rate. Using a LAL gel-clot assay with a sensitivity of 0.06 EU/ml (EU: endotoxin unit), the magnetoelastic sensor based technology can detect the presence of endotoxin at 0.0105 EU/ml in test requiring approximately 20 min. Unlike optical methods used for determining endotoxin concentration, the color of the test solution does not impact the magnetoelastic sensor measurement. Due to the small size of the sensor reader electronics and low cost, the magnetoelastic sensor based endotoxin detection system is ideally suited for wide-spread use in endotoxin screening for sepsis prevention.

Biosensing Techniques↗

A staphylococcal enterotoxin B magnetoelastic immunosensor.

A magnetoelastic immunosensor for detection of staphylococcal enterotoxin B (SEB) is described. The magnetoelastic sensor is a newly developed mass/elasticity-based transducer of high sensitivity having a material cost of approximately $0.001/sensor. Affinity-purified rabbit anti-SEB antibody was covalently immobilized on magnetoelastic sensors, of dimensions 6 mm x 2 mm x 28 microm. The affinity reaction of biotin-avidin and biocatalytic precipitation are used to amplify antigen-antibody binding events on the sensor surface. Horseradish peroxidase (HRP) and alkaline phosphatase were examined as the labeled enzymes to induce biocatalytic precipitation. The alkaline phosphatase substrate, 5-bromo-4-chloro-3-indolyl phosphate (BCIP) produces a dimer, which binds tightly to the sensor surface, inducing a change in sensor resonance frequency. The biosensor demonstrates a linear shift in resonance frequency with staphylococcal enterotoxin B concentration between 0.5 and 5 ng/ml, with a detection limit of 0.5 ng/ml.

Alkaline Phosphatase↗

A magnetoelastic bioaffinity-based sensor for avidin.

A magnetoelastic bioaffinity sensor coupled with biocatalytic precipitation is described for avidin detection. The non-specific adsorption characteristics of streptavidin on different functionalized sensor surfaces are examined. It is found that a biotinylated poly(ethylene glycol) (PEG) interface can effectively block non-specific adsorption of proteins. Coupled with the PEG immobilized sensor surface, alkaline phosphatase (AP) labeled streptavidin is used to track specific binding on the sensor. This mass-change-based signal is amplified by the accumulation on the sensor of insoluble products of 5-bromo-4-chloro-3-indolyl phosphate catalyzed by AP. The resulting mass loading on the sensor surface in turn shifts the resonance frequency of the magnetoelastic sensors, with an avidin detection limit of approximately 200 ng/ml.

Avidin↗

A wireless, remote query glucose biosensor based on a pH-sensitive polymer.

This paper describes a wireless, remote query glucose biosensor using a ribbonlike, mass-sensitive magnetoelastic sensor as the transducer. The glucose biosensor is fabricated by first coating the magnetoelastic sensor with a pH-sensitive polymer and upon it a layer of glucose oxidase (GOx). The pH-responsive polymer swells or shrinks, thereby changing mass, respectively, in response to increasing or decreasing pH values. The GOx-catalyzed oxidation of glucose produces gluconic acid, inducing the pH-responsive polymer to shrink, which in turn decreases the polymer mass. In response to a time-varying magnetic field, a magnetoelastic sensor mechanically vibrates at a characteristic resonance frequency, the value of which inversely depends on sensor mass loading. As the magnetoelastic films are magnetostrictive, the vibrations launch magnetic flux that can be remotely detected using a pickup coil. Hence, changes in the resonance frequency of a passive magnetoelastic transducer are detected on a remote query basis, without the use of physical connections to the sensors.The sensitivity of the glucose biosensors decreases with increasing ionic strength; at physiological salt concentrations, 0.6 mmol/L of glucose can be measured. At glucose concentrations of 1-10 mmol/L, the biosensor response is reversible and linear, with the detection limit of 0.6 mmol/L corresponding to an error in resonance frequency determination of 20 Hz. Since no physical connections between the sensor and the monitoring instrument are required, this sensor can potentially be applied to in vivo and in situ measurement of glucose concentrations.

Acrylates↗

Magnetoelastic immunosensors: amplified mass immunosorbent assay for detection of Escherichia coli O157:H7.

A mass-sensitive magnetoelastic immunosensor for detection of Escherichia coli O157:H7 is described, based on immobilization of affinity-purified antibodies attached to the surface of a micrometer-scale magnetoelastic cantilever. Alkaline phosphatase is used as a labeled enzyme to the anti-E. coli O157:H7 antibody, amplifying the mass change associated with the antibody-antigen binding reaction by biocatalytic precipitation of 5-bromo-4-chloro-3-indolyl phosphate in a pH 10.0 PBS solution. The detection limit of the biosensor is 10(2) E. coli O157:H7 cells/mL. A linear change in the resonance frequency of the biosensor was found to E. coli O157:H7 concentrations ranging from 10(2) to 10(6) cells/mL.