A wireless, remote query glucose biosensor based on a pH-sensitive polymer.

Abstract

This paper describes a wireless, remote query glucose biosensor using a ribbonlike, mass-sensitive magnetoelastic sensor as the transducer. The glucose biosensor is fabricated by first coating the magnetoelastic sensor with a pH-sensitive polymer and upon it a layer of glucose oxidase (GOx). The pH-responsive polymer swells or shrinks, thereby changing mass, respectively, in response to increasing or decreasing pH values. The GOx-catalyzed oxidation of glucose produces gluconic acid, inducing the pH-responsive polymer to shrink, which in turn decreases the polymer mass. In response to a time-varying magnetic field, a magnetoelastic sensor mechanically vibrates at a characteristic resonance frequency, the value of which inversely depends on sensor mass loading. As the magnetoelastic films are magnetostrictive, the vibrations launch magnetic flux that can be remotely detected using a pickup coil. Hence, changes in the resonance frequency of a passive magnetoelastic transducer are detected on a remote query basis, without the use of physical connections to the sensors.The sensitivity of the glucose biosensors decreases with increasing ionic strength; at physiological salt concentrations, 0.6 mmol/L of glucose can be measured. At glucose concentrations of 1-10 mmol/L, the biosensor response is reversible and linear, with the detection limit of 0.6 mmol/L corresponding to an error in resonance frequency determination of 20 Hz. Since no physical connections between the sensor and the monitoring instrument are required, this sensor can potentially be applied to in vivo and in situ measurement of glucose concentrations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Qingyun Cai, Kefeng Zeng, Chuanmin Ruan, Tejal A Desai, Craig A Grimes. 2004-07-15. A wireless, remote query glucose biosensor based on a pH-sensitive polymer.. https://doi.org/10.1021/ac0498516

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Foldable micropatterned hydrogel film made from biocompatible PCL-b-PEG-b-PCL diacrylate by UV embossing.

Foldable hydrogel films with micropatterns measuring 480 microm by 45 microm by 54 microm by 2 cm (width of microchannel by width of microwall by height of wall by length of pattern) were made by UV embossing of a block copolymer of polycaprolactone (PCL) and poly(ethylene glycol) (PEG), specifically PCL-b-PEG-b-PCL-diacrylate (DA), with a polydimethylsiloxane mold. The mold was treated with Ar/CF(4) plasma to simultaneously promote microchannel filling and demolding, and the glass substrate was modified with 3-(trimethoxysilyl) propyl acrylate to promote hydrogel adhesion to avoid delamination of the gel during demolding. The micropatterned hydrogel film was detached from the glass substrate by freeze-drying. As the films were demolded, the microstructured pattern was well replicated in the hydrogel. The gel pattern dimensions shrank with freeze-drying and increased with water swelling, but under both conditions, the gel micropattern morphology was perfectly preserved. PCL-b-PEG-b-PCL-DA hydrogel was found to have good biocompatibility compared with PEGDA hydrogel. A micropattern with a smaller microchannel width of 50 microm was also made. Micropatterned foldable and biocompatible hydrogel films have potential applications in the construction of tissue-engineering scaffolds.

Acrylates↗

Critical review of the epidemiology literature on the potential cancer risks of methyl methacrylate.

OBJECTIVE: To critically review and summarise all of the available epidemiological evidence, both published and unpublished, to date on the carcinogenicity of methyl methacrylate (MMA) to humans. METHODS: The review focused on studies of cast acrylic sheet manufacturing workers because this industry has historically had a potential for exposure to high levels of MMA. The majority of papers for review were identified through Medline (National Library of Medicine) but there is some discussion of two cohort studies and a nested case-control study, which to date have not been published. RESULTS: An increased risk of colorectal cancer was reported in one group of workers highly exposed to MMA and ethyl acrylate (EA) in the manufacture of acrylic sheet. Analysis of colon cancer by cumulative exposure to MMA indicated that the excess was largely confined to the group with the highest exposure. However, a large excess of colon cancer deaths occurred among workers who never worked in a job entailing more than minimal exposure. Studies of other large occupational cohorts of workers potentially exposed to MMA, including some with potentially comparable exposures, have failed to strengthen the evidence that there is a causal association between colorectal cancer and MMA exposure although one reported an excess that did not appear to be exposure-related. Excesses of cancers of the respiratory system and stomach were seen in some cohorts, but not among the acrylic sheet workers who had the increased risk of colorectal cancer. CONCLUSIONS: Excesses of respiratory, stomach and colorectal cancers were observed in some cohorts of workers exposed to MMA. There was little to suggest that MMA exposure was responsible for the excesses of respiratory and stomach cancer and it is more likely that they resulted from unexplained contributions of lifestyle exposures such as cigarette smoking and diet. An excess of colorectal cancer in one group of workers exposed to high levels of MMA and EA during the 1930s and 1940s remains unexplained. However, the lack of consistency in the results of various studies, the absence of dose response and the lack of support from animal toxicology do not provide persuasive evidence that exposure to MMA is a human carcinogen.

Acrylates↗