Evaluation of static physics performance of the jPET-D4 by Monte Carlo simulations.

The jPET-D4 is the first PET scanner to introduce a unique four-layer depth-of-interaction (DOI) detector scheme in order to achieve high sensitivity and uniform high spatial resolution. This paper compares measurement and Monte Carlo simulation results of the static physics performance of this prototype research PET scanner. Measurement results include single and coincidence energy spectra, point and line source sensitivities, axial sensitivity profile (slice profile) and scatter fraction. We use GATE (Geant4 application for tomographic emission) as a Monte Carlo radiation transport model. Experimental results are reproduced well by the simulation model with reasonable assumptions on characteristic responses of the DOI detectors. In a previous study, the jPET-D4 was shown to provide a uniform spatial resolution as good as 3 mm (FHWM). In the present study, we demonstrate that a high sensitivity, 11.3 +/- 0.5%, is provided at the FOV centre. However, about three-fourths of this sensitivity is related to multiple-crystal events, for which some misidentification of the crystal cannot be avoided. Therefore, it is crucial to develop a more efficient way to identify the crystal of interaction and to reduce misidentification in order to make use of these high performance values simultaneously. We expect that effective sensitivity can be improved by replacing the GSO crystals with more absorptive crystals such as BGO and LSO. The results we describe here are essential to take full advantage of the next generation PET systems that have DOI recognition capability.

Algorithms↗

[Comparison of noise equivalent count rate and image quality for two-dimensional and three-dimensional PET scans].

The aim of this study was to investigate the correlation between noise equivalent count (NEC) rates and the signal-to-noise ratio (S/N) in reconstructed images. The NEC rates were determined using uniform 20 cm and 70 cm tall, 20 cm diameter cylinders filled with 11C. The phantoms were scanned in both two-dimensional and three-dimensional modes. The reconstructed image noise was evaluated using FBP and OSEM algorithms (4 iterations and 8 subsets). The images were filtered to a final image resolution of 6.5 mm. From the reconstructed image sets, averages and standard deviations of images were generated, from which the average image S/N (=average/standard deviation) was calculated within an 18 cm central ROI. The S/N of a central slice and an end slice was compared with the NEC. The NEC was found to have a linear relationship to the image S/N of all slices, depending on differences in noise properties specific to the reconstruction algorithm. In two-dimensional mode, although the image S/N of the central slice and the edge slice showed a linear relationship with the NEC, in three-dimensional mode, the S/N of the central slice did not show a relationship with the NEC. The linear relationship was also found in both two- and three-dimensional acquisition modes, as well as for the different activity distributions. These results indicate that the NEC is not only a measure for comparing the count rate performance of imaging systems. However, an absolute evaluation is impossible to depend on reconstruction algorithm, slice number, and phantom type.

Algorithms↗

18F-FDG accumulation in atherosclerosis: use of CT and MR co-registration of thoracic and carotid arteries.

PURPOSE: The purpose of this study was to depict( 18)F-fluoro-2-deoxy-D: -glucose (FDG) accumulation in atherosclerotic lesions of the thoracic and carotid arteries on CT and MR images by means of automatic co-registration software. METHODS: Fifteen hospitalised men suffering cerebral infarction or severe carotid stenosis requiring surgical treatment participated in this study. Automatic co-registration of neck MR images and FDG-PET images and of contrast-enhanced CT images and FDG-PET images was achieved with co-registration software. We calculated the count ratio, which was standardised to the blood pool count of the superior vena cava, for three arteries that branch from the aorta, i.e. the brachial artery, the left common carotid artery and the subclavian artery (n=15), for atherosclerotic plaques in the thoracic aorta (n=10) and for internal carotid arteries with and without plaque (n=13). RESULTS: FDG accumulated to a significantly higher level in the brachial artery, left common carotid artery and left subclavian artery at their sites of origin than in the superior vena cava (p=0.000, p=0.000 and p=0.002, respectively). Chest CT showed no atherosclerotic plaque at these sites. Furthermore, the average count ratio of thoracic aortic atherosclerotic plaques was not higher than that of the superior vena cava. The maximum count ratio of carotid atherosclerotic plaques was significantly higher than that of the superior vena cava but was not significantly different from that of the carotid artery without plaque. CONCLUSION: The results of our study suggest that not all atherosclerotic plaques show high FDG accumulation. FDG-PET studies of plaques with the use of fused images can potentially provide detailed information about atherosclerosis.

Aged↗

[Accuracy of attenuation coefficient obtained by 137Cs single-transmission scanning in PET: comparison with conventional germanium line source].

UNLABELLED: Transmission scanning can be successfully performed with a Cs-137 single-photon-emitting point source for three-dimensional PET imaging. This method was effective for postinjection transmission scanning because of differences in physical energy. However, scatter contamination in the transmission data lowers measured attenuation coefficients. The purpose of this study was to investigate the accuracy of the influence of object scattering by measuring the attenuation coefficients on the transmission images. We also compared the results with the conventional germanium line source method. METHODS: Two different types of PET scanner, the SET-3000 G/X (Shimadzu Corp.) and ECAT EXACT HR(+) (Siemens/CTI) , were used. For the transmission scanning, the SET-3000 G/X and ECAT HR(+) were the Cs-137 point source and Ge-68/Ga-68 line source, respectively. With the SET-3000 G/X, we performed transmission measurement at two energy gate settings, the standard 600-800 keV as well as 500-800 keV. The energy gate setting of the ECAT HR(+) was 350-650 keV. The effects of scattering in a uniform phantom with different cross-sectional areas ranging from 201 cm(2) to 314 cm(2) to 628 cm(2) (apposition of the two 20 cm diameter phantoms) and 943 cm(2) (stacking of the three 20 cm diameter phantoms) were acquired without emission activity. First, we evaluated the attenuation coefficients of the two different types of transmission scanning using region of interest (ROI) analysis. In addition, we evaluated the attenuation coefficients with and without segmentation for Cs-137 transmission images using the same analysis. The segmentation method was a histogram-based soft-tissue segmentation process that can also be applied to reconstructed transmission images. RESULTS: In the Cs-137 experiment, the maximum underestimation was 3% without segmentation, which was reduced to less than 1% with segmentation at the center of the largest phantom. In the Ge-68/Ga-68 experiment, the difference in mean attenuation coefficients was stable with all phantoms. CONCLUSION: We evaluated the accuracy of attenuation coefficients of Cs-137 single-transmission scans. The results for Cs-137 suggest that scattered photons depend on object size. Although Cs-137 single-transmission scans contained scattered photons, attenuation coefficient error could be reduced using by the segmentation method.

Cesium Radioisotopes↗

[Optimization of basic adjustable data-acquisition parameters for continuous three-dimensional whole-body FDG-PET].

UNLABELLED: The SET-3000 G/X (Shimadzu Corp., Kyoto, Japan) has a large aperture and functions as a three-dimensional (3D) dedicated PET scanner. However, the large number of line of responses in the SET-3000 G/X scanner creates a large volume of sinogram data and prolongs reconstruction time in iterative reconstruction. The purpose of this study was to optimize basic acquisition parameters (maximum ring difference and span) for sensitivity and spatial resolution for 3D whole-body (18)F-FDG PET. METHODS: Detector rings and image planes numbered 50 and 99, respectively. In sensitivity measurement, the maximum ring difference (MRD) was changed from 1 to 49. In the measurement of spatial resolution, the span was changed from 3 to 21. For sensitivity and spatial resolution measurements, the standard protocols defined by the Japan Radioisotope Association (JRIA) 1994 and the National Electrical Manufacturers Association (NEMA) NU 2-2001 were used. We also evaluated the corresponding image noise by placing identical ROI on the reconstructed images. RESULTS: The total sensitivity of MRD=49 was 85.7 cps/Bq/ml in a uniform phantom (15 cm diameter, 30 cm tall cylinder) filled with (18)F. This was approximately two times higher than MRD=13. The image noise in the center of the axial FOV decreased with increasing MRD. Spatial resolution was slightly decreased as MRD increased, but axial resolution deteriorated with a span of more than 11. CONCLUSION: Optimum basic data-acquisition parameters for whole-body (18)F-FDG PET were MRD 49 to obtain maximum sensitivity and span 9 to avoid decreasing spatial resolution. Additionally, it was concluded that the basic data-acquisition parameters should be carefully selected for 3D whole-body (18)F-FDG PET in order to maximize the efficiency of PET measurement.

Electronic Data Processing↗

Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.

UNLABELLED: The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is a 3-dimensional (3D) (only) dedicated PET camera with germanium oxyorthosilicate (GSO) and bismuth germanate (BGO) scintillators. The main characteristic of the SET-3000 G/X PET scanner is 3D continuous-emission and spiral-transmission (CEST) scanning, yielding a reduction in whole-body scan time. We evaluated the physical performance of the SET-3000 G/X PET scanner with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. METHODS: A GSO 3D emission scanner is combined with a BGO transmission scanner separated axially by a lead shield. In the GSO scanner, small and thick scintillators (2.45 x 5.1 x 30 mm(3)) are arranged in small blocks (23.1 x 52 mm) to achieve high resolution and a high counting rate. The detector ring has a large solid angle with a diameter of 664 mm and an axial coverage of 260 mm (50 rings). The transmission scanner consists of BGO block detectors with a diameter of 798 mm and an axial width of 23.1 mm and is equipped with a rotating (137)Cs point source of 740 MBq and a tungsten collimator. The low- and high-energy thresholds are set to 400 and 700 keV, respectively, in the emission system. The coincidence time window is set to 6 ns. In CEST acquisition, the patient couch moves continuously through the emission and transmission scanners in a 1-way motion. Emission coincidence data are acquired in the histogram mode with on-the-fly Fourier rebinning, and transmission single data are acquired with emission contamination correction. RESULTS: With the NEMA NU 2-2001 standard, the main performance results were as follows: the average (radial and tangential) transverse and axial spatial resolutions (full width at half maximum) at 1 cm and at 10 cm off axis were 3.49 and 5.04 mm and 4.48 and 5.40 mm, respectively; the average sensitivity for the 2 radial positions (0 and 10 cm) was 20.71 cps/kBq; the scatter fraction was 50%; the peak noise equivalent count rate was 62.3 kcps at 9.8 kBq/mL; and the peak random rate was 542.1 kcps at 37.6 kBq/mL. CONCLUSION: The new integrated SET-3000 G/X PET scanner has good overall performance, including high resolution and sensitivity, and has the potential of reducing whole-body acquisition time to less than 10 min while improving small-lesion detectability with a low radiation dose.

Equipment Design↗

Transaxial system models for jPET-D4 image reconstruction.

A high-performance brain PET scanner, jPET-D4, which provides four-layer depth-of-interaction (DOI) information, is being developed to achieve not only high spatial resolution, but also high scanner sensitivity. One technical issue to be dealt with is the data dimensions which increase in proportion to the square of the number of DOI layers. It is, therefore, difficult to apply algebraic or statistical image reconstruction methods directly to DOI-PET, though they improve image quality through accurate system modelling. The process that requires the most computational time and storage space is the calculation of the huge number of system matrix elements. The DOI compression (DOIC) method, which we have previously proposed, reduces data dimensions by a factor of 1/5. In this paper, we propose a transaxial imaging system model optimized for jPET-D4 with the DOIC method. The proposed model assumes that detector response functions (DRFs) are uniform along line-of-responses (LORs). Then each element of the system matrix is calculated as the summed intersection lengths between a pixel and sub-LORs weighted by a value from the DRF look-up-table. 2D numerical simulation results showed that the proposed model cut the calculation time by a factor of several hundred while keeping image quality, compared with the accurate system model. A 3D image reconstruction with the on-the-fly calculation of the system matrix is within the practical limitations by incorporating the proposed model and the DOIC method with one-pass accelerated iterative methods.

Brain↗

Usefulness of noise adaptive non-linear gaussian filter in FDG-PET study.

OBJECTIVE: In positron emission tomography (PET) studies, shortening transmission (TR) scan time can improve patient comfort and increase scanner throughput. However, PET images from short TR scans may be degraded due to the statistical noise included in the TR image. The purpose of this study was to apply non-linear Gaussian (NLG) and noise adaptive NLG (ANLG) filters to TR images, and to evaluate the extent of noise reduction by the ANLG filter in comparison with that by the NLG filter using phantom and clinical studies. METHODS: In phantom studies, pool phantoms of various diameters and injected doses of 2-deoxy-2-[18F]fluoro-D-glucose (FDG) were used and the coefficients of variation (CVs) of the counts in the TR images processed with the NLG and ANLG filters were compared. In clinical studies, two normal volunteers and 13 patients with tumors were studied. In volunteer studies, the CV values in the liver were compared. In patient studies, the standardized uptake values (SUVs) of tumors in the emission images were obtained after processing the TR images using the NLG and ANLG filters. RESULTS: In phantom studies, the CV values in the TR images processed with the ANLG filter were smaller than those in the images processed with the NLG filter. When using the ANLG filter, their dependency on the phantom size, injected dose of FDG and TR scan time was smaller than when using the NLG filter. In volunteer studies, the CV values in the images processed with the ANLG filter were smaller than those in the images processed with the NLG filter, and were almost constant regardless of the TR scan time. In patient studies, there was an excellent correlation between the SUVs obtained from the images with a TR scan time of 7 min processed with the NLG filter (x) and those obtained from the images with a TR scan time of 4 min processed with the ANLG filter (y) (r = 0.995, y = 1.034x - 0.075). CONCLUSIONS: Our results suggest that the ANLG filter is effective and useful for noise reduction in TR images and shortening TR scan time while maintaining the quantitative accuracy of FDG-PET studies.

Adult↗

[2D imaging simulations of a small animal PET scanner with DOI measurement: jPET-RD.].

We present a preliminary study on the design of a high sensitivity small animal DOI-PET scanner: jPET-RD (for Rodents with DOI detectors), which will contribute to molecular imaging. The 4-layer DOI block detector for the jPET-RD that consists of scintillation crystals (1.4 mm x 1.4 mm x 4.5 mm) and a flat panel position-sensitive photomultiplier tube (52 mm x 52 mm) was previously proposed. In this paper, we investigate imaging performance of the jPET-RD through numerical simulations. The scanner has a hexagonal geometry with a small diameter and a large axial aperture. Therefore DOI information is expected to improve resolution uniformity in the whole field of view (FOV). We simulate the scanner for various parameters of the number of DOI channels and the crystal length. Simulated data are reconstructed using the maximum likelihood expectation maximization with accurate system modeling. The trade-off results between background noise and spatial resolution show that only shortening the length of crystal does not improve the trade-off at all, and that 4-layer DOI information improves uniformity of spatial resolution in the whole FOV. Excellent performance of the jPET-RD can be expected based on the numerical simulation results.

Animals↗

[Basic investigation of data acquisition system for next generation PET scanner].

We are under development of a 3D PET scanner with depth of interaction (DOI) capable of high sensitivity and high resolution. In this paper, we estimated the data transfer rate of data acquisition system of this PET scanner by the simulation studies. A maximum data transfer rate of coincidence pair's event information is 10 Mcps and one coincidence event is a 64-bit data format. A data acquisition system, which fulfills the specification of this scanner, is considered for parallel collection with banks including several coincidence units. Simulator of parallel collection system composed of two stand-alone simulators and the server PC. Each stand-alone simulator is composed of data generation PC, data processing circuit, SCSI and data acquisition PC. As the result of simulation studies, the maximum data transfer rate of the stand-alone simulator was 12.0 MB/s, and the maximum data transfer rates at the server PC with one and two nodes were 11.0 and 21.8 MB/s, respectively. Data transfer rate was improved by parameter optimization of a message size and multi-processing of data acquisition software using RAM-DISK.

Computer Simulation↗

Implementation of continuous 3D whole-body PET scanning using on-the-fly Fourier rebinning.

The continuous scanning mode in three-dimensional (3D) whole-body PET studies has the advantage of axial sensitivity uniformity over the majority of the axial FOV. However, this scan mode requires large data handling compared to conventional discrete scans. In this work, we have implemented and evaluated a new continuous 3D scan method using 'on-the-fly' Fourier rebinning. In this method, sinograms for the pair of rings are added in real-time into the sinograms of the incremented ring pairs by moving the bed axially one detector width at a time. For an N-ring scanner, 2N--1 sinograms are transferred to a host computer at each bed position and rebinned into direct two-dimensional (2D) sinograms using Fourier rebinning. Phantom and human studies showed that the axial image uniformity is achieved without degrading the axial resolution. This method can minimize the time for off-line data processing and makes the continuous 3D scan more feasible in clinical whole-body studies.

Fourier Analysis↗