PubMed Health⌕ Search

PubMed · 16456508

[Optimization of basic adjustable data-acquisition parameters for continuous three-dimensional whole-body FDG-PET].

Abstract

UNLABELLED: The SET-3000 G/X (Shimadzu Corp., Kyoto, Japan) has a large aperture and functions as a three-dimensional (3D) dedicated PET scanner. However, the large number of line of responses in the SET-3000 G/X scanner creates a large volume of sinogram data and prolongs reconstruction time in iterative reconstruction. The purpose of this study was to optimize basic acquisition parameters (maximum ring difference and span) for sensitivity and spatial resolution for 3D whole-body (18)F-FDG PET. METHODS: Detector rings and image planes numbered 50 and 99, respectively. In sensitivity measurement, the maximum ring difference (MRD) was changed from 1 to 49. In the measurement of spatial resolution, the span was changed from 3 to 21. For sensitivity and spatial resolution measurements, the standard protocols defined by the Japan Radioisotope Association (JRIA) 1994 and the National Electrical Manufacturers Association (NEMA) NU 2-2001 were used. We also evaluated the corresponding image noise by placing identical ROI on the reconstructed images. RESULTS: The total sensitivity of MRD=49 was 85.7 cps/Bq/ml in a uniform phantom (15 cm diameter, 30 cm tall cylinder) filled with (18)F. This was approximately two times higher than MRD=13. The image noise in the center of the axial FOV decreased with increasing MRD. Spatial resolution was slightly decreased as MRD increased, but axial resolution deteriorated with a span of more than 11. CONCLUSION: Optimum basic data-acquisition parameters for whole-body (18)F-FDG PET were MRD 49 to obtain maximum sensitivity and span 9 to avoid decreasing spatial resolution. Additionally, it was concluded that the basic data-acquisition parameters should be carefully selected for 3D whole-body (18)F-FDG PET in order to maximize the efficiency of PET measurement.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Keiichi Matsumoto, Keishi Kitamura, Tetsuro Mizuta, Keiji Shimizu, Kenya Murase, Michio Senda. 2006-01-20. [Optimization of basic adjustable data-acquisition parameters for continuous three-dimensional whole-body FDG-PET].. https://doi.org/10.6009/jjrt.62.78

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Filing of applications and requirements for widow's and widower's benefits. Final rule.

We are revising one of our regulations to clarify that we will protect a title II claimant's filing date as of the date the claimant or other proper applicant on the claimant's behalf completes and transmits to the Social Security Administration (SSA) the Personal Information Identification data on the Internet Social Security Benefit Application (ISBA). This revision addresses an aspect of implementing the ISBA to provide certain rights to Internet filers that we afford to other filers. In addition, we are correcting one word in a different title II regulation. The revision is necessary to correctly reflect the circumstances under which a claimant for widow's or widower's benefits as the insured person's surviving divorced spouse would be considered "unmarried."

Electronic Data Processing↗

Computer program for automated sleep depth estimation.

In this article, we present a new implementation of an amplitude-independent method for continuous-scale sleep depth estimation. Having been implemented as an add-on analysis module under commercially available biosignal recording and analysis software, it can be easily applied in clinical routine. The software gives the user full freedom to change all the analysis parameters inside theoretical limits. Computational sleep depth profiles produced by the presented software compare favourably with visual classifications. Future work will concentrate on systematic optimization of analysis parameters, further evaluation of the method with disturbed sleep and application of the method for automated adaptive sleep analysis.

Electronic Data Processing↗