PubMed Health⌕ Search

Biomedical subjects

Kenneth R Wehmeyer

Publications and source records attributed to Kenneth R Wehmeyer.

3 recordsLinked to original sources

Application of multiplexed capillary electrophoresis with laser-induced fluorescence (MCE-LIF) detection for the rapid measurement of endogenous extracellular signal-regulated protein kinase (ERK) levels in cell extracts.

Multiplexed (96-lane) capillary electrophoresis with laser-induced fluorescence (MCE-LIF) detection was used for the rapid analysis of extracellular signal-regulated protein kinase (ERK) levels from in vitro cell extracts. The levels of ERK enzyme in cell extracts were determined by monitoring the conversion of a fluorescent-labeled peptide substrate to a phosphorylated fluorescent-labeled peptide product using MCE-LIF. The incorporation of a fluorescent internal standard was found to improve the precision of the analysis. The enzyme assay conditions including substrate concentration, reaction time and enzyme linear range were rapidly optimized using the MCE-LIF approach for both direct and immunoprecipitation-based ERK assays. The levels of ERK from in vitro cell extracts stimulated with angiopoietin 1 (Ang1*) were determined using the MCE-LIF approach. The advantages of MCE-LIF for developing and applying enzyme assays, as well as the figures of merit for the direct and immunoprecipitation ERK assays, are discussed.

Cell Extracts↗

Determination of endogenous extracellular signal-regulated protein kinase by microchip capillary electrophoresis.

The application of microchip capillary electrophoresis (CE) to the assay of extracellular signal-regulated protein kinase (ERK) is presented. In this assay, ERK catalyzes the transfer of gamma-phosphate from adenosine 5(')-triphosphate to the threonine residue of a fluorescently labeled nonapeptide (APRTPGGRR), and the phosphorylated and nonphosphorylated peptides were detected by fluorescence. The phosphorylated and nonphosphorylated peptides and the internal standard were separated within 20s, and the increase in magnitude of the phosphorylated peptide peak was monitored to assess ERK activity. ERK reactions were prepared off-chip and analyzed on a single-lane glass microchip fabricated by standard methods. It was demonstrated that microchip CE could be used to measure endogenous amounts of ERK by spiking known concentrations of recombinant ERK2 into the lysates of serum-starved human umbilical vein endothelial cells (HUVEC) and recovering between 90 and 100% for all samples. Endogenous ERK activity was determined by microchip where HUVEC were stimulated with 500pM vascular endothelial growth factor (VEGF) at different times before cell lysis. The results showed a transient VEGF-mediated ERK activation that peaked at 10min, which was consistent with previous reports using conventional techniques. The microchip assay provided a rapid, accurate, and precise alternative to conventional methods of determining endogenous ERK activity.

Cells, Cultured↗

Semi-automated liquid--liquid back-extraction in a 96-well format to decrease sample preparation time for the determination of dextromethorphan and dextrorphan in human plasma.

A semi-automated, 96-well based liquid-liquid back-extraction (LLE) procedure was developed and used for sample preparation of dextromethorphan (DEX), an active ingredient in many over-the-counter cough formulations, and dextrorphan (DOR), an active metabolite of DEX, in human plasma. The plasma extracts were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). The analytes were isolated from human plasma using an initial ether extraction, followed by a back extraction from the ether into a small volume of acidified water. The acidified water isolated from the back extraction was analyzed directly by LC-MS-MS, eliminating the need for a dry down step. A liquid handling system was utilized for all aspects of liquid transfers during the LLE procedure including the transfer of samples from individual tubes into a 96-well format, preparation of standards, addition of internal standard and the addition and transfer of the extraction solvents. The semi-automated, 96-well based LLE procedure reduced sample preparation time by a factor of four versus a comparable manually performed LLE procedure.

Automation↗