PubMed Health⌕ Search

Biomedical subjects

Kentaro Uesugi

Publications and source records attributed to Kentaro Uesugi.

12 recordsLinked to original sources

Elemental compositions of comet 81P/Wild 2 samples collected by Stardust.

We measured the elemental compositions of material from 23 particles in aerogel and from residue in seven craters in aluminum foil that was collected during passage of the Stardust spacecraft through the coma of comet 81P/Wild 2. These particles are chemically heterogeneous at the largest size scale analyzed ( approximately 180 ng). The mean elemental composition of this Wild 2 material is consistent with the CI meteorite composition, which is thought to represent the bulk composition of the solar system, for the elements Mg, Si, Mn, Fe, and Ni to 35%, and for Ca and Ti to 60%. The elements Cu, Zn, and Ga appear enriched in this Wild 2 material, which suggests that the CI meteorites may not represent the solar system composition for these moderately volatile minor elements.

Journal Article↗

Small airway changes in healthy and ovalbumin-treated mice during quasi-static lung inflation.

Previously, we developed a synchrotron radiation CT system to evaluate the morphometric changes (length and diameter, D) and small airway compliance (sC(aw)) of euthanized mice under quasi-static inflation [Sera, T., Uesugi, K., Yagi, N., 2005. Localized morphometric deformations of small airways and alveoli in intact mouse lungs under quasi-static inflation. Respir. Physiol. Neurobiol. 147, 51-63). Using this system, this study compared normal and asthmatic small airways. Ovalbumin-treated mice were used as an asthma model. Compared with the values at functional residual capacity, D of normal and asthmatic small airways (D<200microm) increased by 48% and 36% at the end of tidal inspiration. For larger airways (D>500microm), the increases were 23% and 20%, respectively. The ratio of the sC(aw) of asthmatic small airways to that of healthy small airways was 0.57, and the ratio was 0.70 for larger airways. The morphometric changes and sC(aw) in asthma model mice were significantly lower than those of healthy mice. The differences in sC(aw) between healthy and asthma model mice were greater for smaller airways.

Animals↗

Fast tomography using quasi-monochromatic undulator radiation.

A beamline with a helical undulator has been used without a monochromator for fast high-resolution tomographic imaging with an X-ray energy of 12.4-16.5 keV and an energy bandwidth of 2-3%. The X-ray beam was expanded with two mirrors to 12 mm x 4 mm. The X-ray field was made uniform by a diffuser. The detector pixel size was 9.9 microm x 9.9 microm. At the highest speed, a 180 degrees scan was completed in 6 s with 454 projections. Beam-hardening effects were not significant. This technique may be useful in studying time-dependent structural changes of soft materials such as polymers and biological samples.

Animals↗

Monochromatic synchrotron radiation muCT reveals disuse-mediated canal network rarefaction in cortical bone of growing rat tibiae.

The purpose of this study was to demonstrate the ability of computed microtomography based on monochromatic synchrotron radiation (SRmuCT) in microstructural analysis of cortical bone. Tibial diaphyses of growing rats (14 wk, n = 8) undergoing unilateral sciatic neurectomy 8 wk before study were imaged with spatial volume resolution of 5.83 x 5.83 x 5.83 microm3 by SRmuCT (20 keV) at the synchrotron radiation facility (SPring-8). Reconstructed image data were translated into local mineral densities by using a calibrated linear relationship between linear absorption coefficients and concentrations of homogeneous K2HPO4 solution. Pure bone three-dimensional images, produced by simple thresholding at a bone mineral density of 0.82 g/cm3, were analyzed for macro- and microscopic structural properties. In neurectomized hindlimbs, cortical canal network rarefaction as well as bone atrophy were found. The former was characterized by 30% smaller porosity, 11% smaller canal density in transverse section, and 38% smaller canal connectivity density than those in contralateral bone. On the other hand, no difference was found in bone mineral density between neurectomized and intact hindlimbs (1.37 vs. 1.36 g/cm3). In conclusion, SRmuCT is a promising method for the three-dimensional analysis of cortical microstructure and the degree of mineralization in small animals.

Absorptiometry, Photon↗

Localized morphometric deformations of small airways and alveoli in intact mouse lungs under quasi-static inflation.

Localized morphometric deformations of small airways and alveoli during respiration have several biomechanical and physiological implications. We developed fast synchrotron radiation CT system to visualize the small airways and alveoli of an intact mouse lung without fixation and dehydration, and analyzed their localized morphometric deformations between functional residual capacity (FRC) and total lung capacity (TLC). The maximum resolution of 32.6lp/mm at the 5% modulation transfer function level can be achieved with 11.8-microm voxels and 7-min scanning. Compared with the values at FRC, the diameter and length for smaller airways (diameter at FRC <200 microm) increased by 68.8% and 29.5% (averaged value), and those for larger airways (diameter at FRC >400 microm) increased by 45.2 and 22.9% (averaged value), at TLC. Moreover we defined the volume behavior as the percentage of airway volume at FRC for TLC. The volume behavior for the small airways was not similar to that of the lung volume. These results indicated that all airways did not behave homogenously.

Animals↗

Morphometric deformations of small airways and alveoli under quasi-static inflation process.

Localized morphometric deformations of small airways and alveoli during respiration have many biomedical and physiological implications. We developed fast synchrotron radiation CT system to visualize the small airways and alveoli of an intact mouse lung without fixation and dehydration, and analyzed their localized morphometric deformations between functional residual capacity (FRC) and total lung capacity (TLC). In the diameter behavior, the averaged and range values were significantly larger for smaller airways (68.8%, range: 0.36-0.89) than larger airways (45.2%, range: 0.40-0.57). These results indicated that the airway did not deformed in same manner and that these morphological differences characterized the heterogeneous lung function.

Air Pressure↗

Structural inhomogeneity in mammography quality control phantoms detected by refraction-enhanced synchrotron radiation imaging.

Synchrotron radiation imaging with the refraction-enhancement mode visualized structural inhomogeneities in phantoms used for image quality control of mammography. Eight phantoms were examined, all of which were manufactured in the United States and approved by the American College of Radiology as dedicated phantoms. In addition to fiber- and mass-mimicking test objects, each phantom has 5 groups of calcification specks of various sizes. Synchrotron radiation (SR) imaging was performed at Spring-8, a synchrotron radiation facility in Japan. Images were obtained with monochromatic 20-keV x-ray beams, a radiation field of 15 mm X 26 mm at a sample plane, a CCD camera with a resolution of 6 micrometers as a detector, and a sample-to-detector distance of 10 to 11 m. Two hundred and forty specks were evaluated in total in the SR images, and the surrounding area of each speck was also included. Evaluation of the images showed that 14 crack-like structures were depicted near specks, and there were 62 specks with attached void(s) or air bubble(s). Refraction-enhanced SR imaging sensitively detected structural inhomogeneities and abnormalities in phantoms which were implicitly agreed to have a homogeneous matrix and test objects without foreign substances. A possible manufacturing-dependent quality issue was identified. The effect of inhomogeneities detected by SR imaging on visual scoring of specks could not be identified in the tested phantoms; this should be assessed on images of other phantoms in a future study.

Mammography↗

A large-area CMOS imager as an X-ray detector for synchrotron radiation experiments.

The performance of a CMOS flatpanel imager from Hamamatsu Photonics (C7942) has been tested in various synchrotron radiation experiments. This detector has a detection area of about 120 mm x 120 mm with 0.05 mm pixels, and a frame rate of 2 s(-1). The commercially available product was insensitive to X-rays with an energy lower than 15 keV, but slight modifications solved this problem. Images obtained in small-angle scattering, protein crystallography and medical imaging experiments were all of high quality. The fast readout and the large area are advantageous in real-time imaging. Although its noise level is higher than the area detectors that are currently used in synchrotron radiation experiments, it is particularly useful in experiments where other bulky detectors cannot be used. Its relatively low price (about 30,000 US dollars) makes it a unique option in the choice of detectors.

Animals↗

Three-dimensional diffusion of non-sorbing species in porous sandstone: computer simulation based on X-ray microtomography using synchrotron radiation.

The diffusion pathways of porous sandstone were examined by a three-dimensional (3-D) imaging technique based on X-ray computed tomography (CT) using the SPring-8 (Super Photon ring-8 GeV, Hyogo, Japan) synchrotron radiation facility. The analysis was undertaken to develop better understanding of the diffusion pathways in natural rock as a key factor in clarifying the detailed mechanism of the diffusion of radionuclides and water molecules through the pore spaces of natural barriers in underground nuclear waste disposal facilities. A cylindrical sample (diameter 4 mm, length 6 mm) of sandstone (porosity 0.14) was imaged to obtain a 3-D image set of 450(3) voxels=2.62(3) mm(3). Through cluster-labeling analysis of the 3-D image set, it was revealed that 89% of the pore space forms a single large pore-cluster responsible for macroscopic diffusive transport, while only 11% of the pore space is made up of isolated pores that are not involved in long-range diffusive transport. Computer simulations of the 3-D diffusion of non-sorbing random walkers in the largest pore cluster were performed to calculate the surface-to-volume ratio of the pore, tortuosity (diffusion coefficient in free space divided by that in porous rock). The results showed that (i) the simulated surface-to-volume ratio is about 60% of the results obtained by conventional pulsed-field-gradient proton nuclear magnetic resonance (NMR) laboratory experiments and (ii) the simulated tortuosity is five to seven times larger than the results of laboratory diffusion experiments using non-sorbing I(-) and Br(-). These discrepancies are probably attributed to the intrinsic sample heterogeneity and limited spatial resolution of the CT system. The permeability was also estimated based on the NMR diffusometry theory using the results of the random walk simulations via the Kozeny-Carman equation. The estimated permeability involved an error of about 20% compared with the permeability measured by the conventional method, suggesting that the diffusometry-based NMR well logging with gradient coils is applicable to the in-situ permeability measurement of strata. The present study demonstrated that X-ray CT using synchrotron radiation is a powerful tool for obtaining 3-D pore structure images without the beam-hardening artifacts inevitable in conventional CT using X-ray tubes.

Absorption↗

Electron density measurement with dual-energy x-ray CT using synchrotron radiation.

Monochromatic x-ray computed tomography (CT) at two different energies provides information about electron density of human tissue without ambiguity due to the beam hardening effect. This information makes the treatment planning for proton and heavy-ion radiotherapy more precise. We have started a feasibility study on dual energy x-ray CT by using synchrotron radiation. A translation-rotation scanning CT system was developed for quantitative measurement in order to clarify what precision in the measurement was achieved. Liquid samples of solutions of K2HPO4 and solid samples of tissue equivalent materials were used to simulate human tissue. The experiments were carried out using monochromatic x-rays with energies of 40, 70 and 80 keV produced by monochromatizing synchrotron radiation. The solid samples were also measured in a complementary method using high-energy carbon beams to evaluate the electron densities. The measured electron densities were compared with the theoretical values or the values measured in the complementary method. It was found that these values were in agreement in 0.9% on average. Effective atomic numbers were obtained as well from dual-energy x-ray CT. The tomographic image based on each of the electron densities and the effective atomic number presents a different feature of the material, and its contrast drastically differs from that in a conventional CT image.

Connective Tissue↗

Bone structure and mineralization demonstrated using synchrotron radiation computed tomography (SR-CT) in animal models: preliminary findings.

We investigated the ability of synchrotron radiation computed tomography (SR-CT) to demonstrate trabecular microstructure, detail of trabecular surfaces, and mineralization of bones. Eight rat vertebrae, six rat tibiae, and eight minipig vertebrae were scanned using SR-CT at the synchrotron radiation facility Super Photon ring-8GeV (SPring-8). Images obtained using conventional micro-CT, scanning electron microscopy (SEM), and contact microradiography (CMR) were compared with the SR-CT images. SR-CT showed high image quality without visible partial volume effect. Three-dimensional SR-CT revealed shallow concavities in the bone surface, which were considered to correspond to osteoclastic resorption areas, as well as the connectivity, anisotropy, and shape (rod- or platelike) of trabeculae. Two-dimensional SR-CT showed different density along the surface of the trabecular bone, indicating the degree of bone mineralization. In conclusion, SR-CT seems to be a useful tool for delineating trabecular surfaces, evaluating bone mineralization, and revealing precise trabecular structure.

Animals↗

X-ray refraction-enhanced imaging and a method for phase retrieval for a simple object.

Refraction-enhanced imaging is now widely used for imaging low-absorption-contrast specimens in the hard X-ray region. However, the interpretation of the details of a refraction-enhanced image is not always clear. In this paper the theoretical treatment of refraction-enhanced imaging and a method for phase retrieval from refraction-contrast images are discussed in comparison with angular-deflection mapping of the transmitting beam. The problems of thick and complicated objects are also discussed.

Birefringence↗