Assessment of bolus injection protocol with appropriate concentration for quantitative assessment of pulmonary perfusion by dynamic contrast-enhanced MR imaging.

PURPOSE: To determine the appropriate concentration for quantitative assessment of dynamic contrast-enhanced pulmonary MR imaging. MATERIALS AND METHODS: A total of 40 consecutive patients with small bronchioalveolar carcinoma underwent perfusion single-photon emission tomography (SPECT) and three-dimensional (3D) dynamic MR imaging with a 3D radiofrequency spoiled gradient-echo sequence. In each patient, 5 mL of contrast media with 0.1, 0.3, and 0.5 mmol/mL were administered at a rate of 5 mL/second. All patients were divided into two groups (<70 kg and > or =70 kg) for assessment of appropriate concentration to quantitatively assess regional perfusion parameter in routine clinical practice. Pulmonary blood flow (PBF) in each protocol was calculated from a signal intensity (SI)-time course curve. Differences and limits of agreement of PBF between dynamic MR imaging (PBF(MR)) using three different concentrations and perfusion SPECT (PBF(SPECT)) were statistically compared in both patient groups. RESULTS: PBF(MR) using 0.3 mmol/mL in the <70-kg group and 0.5 mmol/mL in the > or =70-kg group showed no significant difference compared with PBF(SPECT) (P > 0.05). Limits of agreements in 0.3 mmol/mL in the <70-kg group and 0.5 mmol/mL in the > or =70-kg group were smaller than those of the other concentrations and small enough for clinical purposes. CONCLUSION: Appropriate concentrations provide accurate and reproducible assessments of regional pulmonary perfusion parameters on 3D dynamic MR perfusion imaging. We suggest using 5 mL of contrast media with 0.3 mmol/mL for patients weighing less than 70 kg and 0.5 mmol/mL for patients weighing 70 kg or more.

Aged↗

Primary pulmonary hypertension: 3D dynamic perfusion MRI for quantitative analysis of regional pulmonary perfusion.

OBJECTIVE: The purpose of this study was to determine whether quantitative pulmonary perfusion parameters obtained from 3D dynamic contrast-enhanced MR perfusion data can be used to assess the severity of primary pulmonary hypertension (PPH) as indicated by pulmonary vascular resistance (PVR) and mean pulmonary artery pressure (MPAP). CONCLUSION: Three-dimensional dynamic contrast-enhanced MRI has potential for assessment of disease severity as indicated by PVR and MPAP in patients with PPH.

Adult↗

[Comparison of noise equivalent count rate and image quality for two-dimensional and three-dimensional PET scans].

The aim of this study was to investigate the correlation between noise equivalent count (NEC) rates and the signal-to-noise ratio (S/N) in reconstructed images. The NEC rates were determined using uniform 20 cm and 70 cm tall, 20 cm diameter cylinders filled with 11C. The phantoms were scanned in both two-dimensional and three-dimensional modes. The reconstructed image noise was evaluated using FBP and OSEM algorithms (4 iterations and 8 subsets). The images were filtered to a final image resolution of 6.5 mm. From the reconstructed image sets, averages and standard deviations of images were generated, from which the average image S/N (=average/standard deviation) was calculated within an 18 cm central ROI. The S/N of a central slice and an end slice was compared with the NEC. The NEC was found to have a linear relationship to the image S/N of all slices, depending on differences in noise properties specific to the reconstruction algorithm. In two-dimensional mode, although the image S/N of the central slice and the edge slice showed a linear relationship with the NEC, in three-dimensional mode, the S/N of the central slice did not show a relationship with the NEC. The linear relationship was also found in both two- and three-dimensional acquisition modes, as well as for the different activity distributions. These results indicate that the NEC is not only a measure for comparing the count rate performance of imaging systems. However, an absolute evaluation is impossible to depend on reconstruction algorithm, slice number, and phantom type.

Algorithms↗

[Development of an automatic analytical tool for quantitative cerebral blood flow measurement using 99mTc-ECD, and verification of clinical examples].

The following process conventionally has been followed to develop quantitative images of cerebral blood flow: (1) mean cerebral blood flow (mCBF) is calculated by the Patlak plot method; (2) a SPECT slice that includes the basal ganglia is selected; and (3) based on the value of mCBF calculated by the Patlak plot method, the SPECT slice is corrected by the Lassen method and developed into a SPECT image of quantitative regional cerebral blood flow. However, this process is complicated, and the values of rCBF have been reported to fluctuate because selection of the SPECT slice and the ROI setting are in the hands of the operator. We have developed new software that automates this analysis. This software enables automatic processing simply by inputting the value of mCBF in the normal hemisphere. Since there is no need for manual operations such as setting the ROI, reproducibility is improved as well. Regional cerebral blood flow as determined by this software is quite similar to that calculated by the conventional method, so the existing clinical evaluation does not need to be changed. This software is considered to be useful.

Adult↗

Heterogeneity of posterior limbic perfusion in very early Alzheimer's disease.

PURPOSE: This study was designed to quantify the heterogeneity of cerebral perfusion on SPECT images in elderly controls and Alzheimer's disease (AD) patients in mild stage using a three-dimensional fractal analysis (3D-FA). MATERIAL AND METHOD: Seventy-five patients with possible and probable AD based on the NINCDS/ADRDA criteria, and thirty-one elderly controls underwent 99mTc-HMPAO SPECT scanning. Dementia severity was assessed using the clinical dementia rating (CDR). Patients with CDR scores of 0.5 (n=33) were classified as "very early" and those with CDR 1 (n=42) as "early". We delineated the SPECT images using 2 cutoffs (35% and 50% cutoffs of the maximal voxel radioactivity) and measured the number of voxels in the areas included by the contours obtained with each cutoff level. The fractal dimension (FD) was calculated by relating the logarithms of cutoff level and the number of voxels. Posterior limbic images were reconstructed at 30 degrees positive to the coronal plane, and posterior limbic FD was calculated. RESULT: Posterior limbic FD for early AD, very early AD, and control groups were 1.03+/-0.16, 1.02+/-0.17, and 0.87+/-0.14 (P=0.001 versus early AD group, P=0.001 versus very early AD). Use of the posterior limbic FD and the ratio of posterior limbic FD to total FD separated very early AD patients from controls with a sensitivity of 76% and a specificity of 81%. CONCLUSION: 3D-FA indicated significant differences in the heterogeneity of CBF distribution between patients with AD in mild stage and elderly controls. Posterior limbic FD may be useful for easily and objectively distinguishing patients with very early AD from aging people.

Aged↗

[Accuracy of attenuation coefficient obtained by 137Cs single-transmission scanning in PET: comparison with conventional germanium line source].

UNLABELLED: Transmission scanning can be successfully performed with a Cs-137 single-photon-emitting point source for three-dimensional PET imaging. This method was effective for postinjection transmission scanning because of differences in physical energy. However, scatter contamination in the transmission data lowers measured attenuation coefficients. The purpose of this study was to investigate the accuracy of the influence of object scattering by measuring the attenuation coefficients on the transmission images. We also compared the results with the conventional germanium line source method. METHODS: Two different types of PET scanner, the SET-3000 G/X (Shimadzu Corp.) and ECAT EXACT HR(+) (Siemens/CTI) , were used. For the transmission scanning, the SET-3000 G/X and ECAT HR(+) were the Cs-137 point source and Ge-68/Ga-68 line source, respectively. With the SET-3000 G/X, we performed transmission measurement at two energy gate settings, the standard 600-800 keV as well as 500-800 keV. The energy gate setting of the ECAT HR(+) was 350-650 keV. The effects of scattering in a uniform phantom with different cross-sectional areas ranging from 201 cm(2) to 314 cm(2) to 628 cm(2) (apposition of the two 20 cm diameter phantoms) and 943 cm(2) (stacking of the three 20 cm diameter phantoms) were acquired without emission activity. First, we evaluated the attenuation coefficients of the two different types of transmission scanning using region of interest (ROI) analysis. In addition, we evaluated the attenuation coefficients with and without segmentation for Cs-137 transmission images using the same analysis. The segmentation method was a histogram-based soft-tissue segmentation process that can also be applied to reconstructed transmission images. RESULTS: In the Cs-137 experiment, the maximum underestimation was 3% without segmentation, which was reduced to less than 1% with segmentation at the center of the largest phantom. In the Ge-68/Ga-68 experiment, the difference in mean attenuation coefficients was stable with all phantoms. CONCLUSION: We evaluated the accuracy of attenuation coefficients of Cs-137 single-transmission scans. The results for Cs-137 suggest that scattered photons depend on object size. Although Cs-137 single-transmission scans contained scattered photons, attenuation coefficient error could be reduced using by the segmentation method.

Cesium Radioisotopes↗

[Optimization of basic adjustable data-acquisition parameters for continuous three-dimensional whole-body FDG-PET].

UNLABELLED: The SET-3000 G/X (Shimadzu Corp., Kyoto, Japan) has a large aperture and functions as a three-dimensional (3D) dedicated PET scanner. However, the large number of line of responses in the SET-3000 G/X scanner creates a large volume of sinogram data and prolongs reconstruction time in iterative reconstruction. The purpose of this study was to optimize basic acquisition parameters (maximum ring difference and span) for sensitivity and spatial resolution for 3D whole-body (18)F-FDG PET. METHODS: Detector rings and image planes numbered 50 and 99, respectively. In sensitivity measurement, the maximum ring difference (MRD) was changed from 1 to 49. In the measurement of spatial resolution, the span was changed from 3 to 21. For sensitivity and spatial resolution measurements, the standard protocols defined by the Japan Radioisotope Association (JRIA) 1994 and the National Electrical Manufacturers Association (NEMA) NU 2-2001 were used. We also evaluated the corresponding image noise by placing identical ROI on the reconstructed images. RESULTS: The total sensitivity of MRD=49 was 85.7 cps/Bq/ml in a uniform phantom (15 cm diameter, 30 cm tall cylinder) filled with (18)F. This was approximately two times higher than MRD=13. The image noise in the center of the axial FOV decreased with increasing MRD. Spatial resolution was slightly decreased as MRD increased, but axial resolution deteriorated with a span of more than 11. CONCLUSION: Optimum basic data-acquisition parameters for whole-body (18)F-FDG PET were MRD 49 to obtain maximum sensitivity and span 9 to avoid decreasing spatial resolution. Additionally, it was concluded that the basic data-acquisition parameters should be carefully selected for 3D whole-body (18)F-FDG PET in order to maximize the efficiency of PET measurement.

Electronic Data Processing↗

Quantitative study of changes in oxidative metabolism during visual stimulation using absolute relaxation rates.

In the context of quantitative functional MRI (fMRI), deoxyhemoglobin (dHb) content is the essential physiological parameter for calibrating the blood oxygenation level-dependent (BOLD) signal. In studies on humans, the baseline dHb content or its equivalent has been evaluated indirectly by means of carbon dioxide breathing as a physiological reference condition. In this study with normal volunteers, quantitative mapping of baseline dHb content was performed in a direct manner by measuring the reversible contribution of the effective transverse relaxation rate. The BOLD signal change in the visual cortex during 8 Hz flicker visual stimulation was calibrated based on the quantitative map of baseline dHb content. The calibrated relaxation rate change that represents the stimulation-induced fractional change of dHb content decreased by 14% within the activated visual cortex. Simultaneous measurement of cerebral blood flow (CBF) with BOLD showed an increase of 59%. From the calibrated relaxation rate and CBF changes, the cerebral metabolic rate of oxygen (CMRO2) was calculated to increase by 19-28% within the activated visual cortex. The ratio of the CBF increase to the CMRO2 increase was 2-3:1, which agreed well with results of similar quantitative fMRI studies for humans. The method proposed here for quantitative evaluation of the BOLD signal may be applicable not only to fMRI for normal human subjects, but also to physiologically altered or diseased states, because it requires no physiological perturbation.

Adult↗

Automatic volumetric measurement of segmented brain structures on magnetic resonance imaging.

PURPOSE: The purpose of this study was to produce a fully automatic volumetric segmented brain image system (AVSIS) and to evaluate its utility for measuring hippocampal volumes and total intracranial volume (TIV). MATERIALS AND METHODS: We developed a combination technique comprising an anatomical standardization technique to measure TIV, whole brain volume (WBV), and hippocampal volume obtained by magnetic resonance (MR) imaging. Altogether, 15 healthy volunteers and 15 patients with Alzheimer's disease (AD) underwent three-dimensional spoiled gradient echo (3D-SPGR) imaging. Three measurements were performed by manual volumetry as the gold standard, a previous semiautomatic method, and our new method, AVSIS. RESULTS: WBV and hippocampal volume in the AD group were significantly smaller than those in the healthy volunteer group measured by the semiautomatic method, manual method, and AVSIS. Each volume measured by AVSIS or semiautomatic method correlated with that measured by the manual method. The correlation coefficients between TIVs, WBVs, or hippocampal volumes measured by AVSIS and the manual method were 0.910, 0.902, and 0.918, respectively; the correlation coefficients between TIVs, or WBVs, measured by the previous semiautomatic method and the manual method were 0.875, and 0.886, respectively. CONCLUSION: We developed a system for a fully automatic measurement of segmented brain structures and obtained good results.

Age Factors↗

Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.

UNLABELLED: The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is a 3-dimensional (3D) (only) dedicated PET camera with germanium oxyorthosilicate (GSO) and bismuth germanate (BGO) scintillators. The main characteristic of the SET-3000 G/X PET scanner is 3D continuous-emission and spiral-transmission (CEST) scanning, yielding a reduction in whole-body scan time. We evaluated the physical performance of the SET-3000 G/X PET scanner with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. METHODS: A GSO 3D emission scanner is combined with a BGO transmission scanner separated axially by a lead shield. In the GSO scanner, small and thick scintillators (2.45 x 5.1 x 30 mm(3)) are arranged in small blocks (23.1 x 52 mm) to achieve high resolution and a high counting rate. The detector ring has a large solid angle with a diameter of 664 mm and an axial coverage of 260 mm (50 rings). The transmission scanner consists of BGO block detectors with a diameter of 798 mm and an axial width of 23.1 mm and is equipped with a rotating (137)Cs point source of 740 MBq and a tungsten collimator. The low- and high-energy thresholds are set to 400 and 700 keV, respectively, in the emission system. The coincidence time window is set to 6 ns. In CEST acquisition, the patient couch moves continuously through the emission and transmission scanners in a 1-way motion. Emission coincidence data are acquired in the histogram mode with on-the-fly Fourier rebinning, and transmission single data are acquired with emission contamination correction. RESULTS: With the NEMA NU 2-2001 standard, the main performance results were as follows: the average (radial and tangential) transverse and axial spatial resolutions (full width at half maximum) at 1 cm and at 10 cm off axis were 3.49 and 5.04 mm and 4.48 and 5.40 mm, respectively; the average sensitivity for the 2 radial positions (0 and 10 cm) was 20.71 cps/kBq; the scatter fraction was 50%; the peak noise equivalent count rate was 62.3 kcps at 9.8 kBq/mL; and the peak random rate was 542.1 kcps at 37.6 kBq/mL. CONCLUSION: The new integrated SET-3000 G/X PET scanner has good overall performance, including high resolution and sensitivity, and has the potential of reducing whole-body acquisition time to less than 10 min while improving small-lesion detectability with a low radiation dose.

Equipment Design↗

Quantification of left ventricular volumes from cardiac cine MRI using active contour model combined with gradient vector flow.

We investigated the feasibility of combining the active contour model with gradient vector flow (Snakes-GVF) to estimate left ventricular (LV) volumes from cardiac cine magnetic resonance imaging (MRI). MRI data were acquired from 27 patients, including 14 adults (9 men, 5 women, 55.0+/-23.3 years) and 13 children (10 boys, 3 girls, 2.7+/-2.1 years) using Gyroscan Intera (1.5 Tesla, Philips Medical Systems). LV volumes were calculated by adding the areas surrounded by the contour extracted by Snakes-GVF and compared with volumes estimated by manual tracing. Those estimated by Snakes-GVF [y (mL)] correlated well with those estimated by manual tracing [x (mL)]. In adult cases, the regression equation and correlation coefficient were y=1.008x - 0.517 and 0.996, respectively. In pediatric cases, they were y=1.174x - 2.542 and 0.992, respectively. In conclusion, Snakes-GVF is a powerful and useful tool for quantifying LV volumes using cardiac MRI.

Cardiac Volume↗

Fractal analysis of bone architecture at distal radius.

Bone strength depends on bone quality (architecture, turnover, damage accumulation, and mineralization) as well as bone mass. In this study, human bone architecture was analyzed using fractal image analysis, and the clinical relevance of this method was evaluated. The subjects were 12 healthy female controls and 16 female patients suspected of having osteoporosis (age range, 22-70 years; mean age, 49.1 years). High-resolution CT images of the distal radius were acquired and analyzed using a peripheral quantitative computed tomography (pQCT) system. On the same day, bone mineral densities of the lumbar spine (L-BMD), proximal femur (F-BMD), and distal radius (R-BMD) were measured by dual-energy X-ray absorptiometry (DXA). We examined the correlation between the fractal dimension and six bone mass indices. Subjects diagnosed with osteopenia or osteoporosis were divided into two groups (with and without vertebral fracture), and we compared measured values between these two groups. The fractal dimension correlated most closely with L-BMD (r=0.744). The coefficient of correlation between the fractal dimension and L-BMD was very similar to the coefficient of correlation between L-BMD and F-BMD (r=0.783) and the coefficient of correlation between L-BMD and R-BMD (r=0.742). The fractal dimension was the only measured value that differed significantly between both the osteopenic and the osteoporotic subjects with and without vertebral fracture. The present results suggest that the fractal dimension of the distal radius can be reliably used as a bone strength index that reflects bone architecture as well as bone mass.

Absorptiometry, Photon↗

Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies.

The purpose of this study was to investigate the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using multi-detector row CT (MDCT). Following the standard CT perfusion study protocol, continuous (cine) scans (1 s/rotation x 60 s) consisting of four 5 mm thick contiguous slices were performed using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. We generated the simulated images with tube currents of 50 mA, 100 mA and 150 mA by adding the corresponding noise to the raw scan data of the original image acquired above using a noise simulation tool. From the original and simulated images, we generated the functional images of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in seven patients with cerebrovascular disease, and compared the correlation coefficients (CCs) between the perfusion parameter values obtained from the original and simulated images. The coefficients of variation (CVs) in the white matter were also compared. The CC values deteriorated with decreasing tube current. There was a significant difference between 50 mA and 100 mA for all perfusion parameters. The CV values increased with decreasing tube current. There were significant differences between 50 mA and 100 mA and between 100 mA and 150 mA for CBF. For CBV and MTT, there was also a significant difference between 150 mA and 200 mA. This study will be useful for understanding the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using MDCT, and for selecting the tube current.

Aged↗

[Fractal analysis of trabecular architecture: with special reference to slice thickness and pixel size of the image].

Many analyses of bone microarchitecture using three-dimensional images of micro CT (microCT) have been reported recently. However, as extirpated bone is the subject of measurement on microCT, various kinds of information are not available clinically. Our aim is to evaluate usefulness of fractal dimension as an index of bone strength different from bone mineral density in in-vivo, to which microCT could not be applied. In this fundamental study, the relation between pixel size and the slice thickness of images was examined when fractal analysis was applied to clinical images. We examined 40 lumbar spine specimens extirpated from 16 male cadavers (30-88 years; mean age, 60.8 years). Three-dimensional images of the trabeculae of 150 slices were obtained by a microCT system under the following conditions: matrix size, 512 x 512; slice thickness, 23.2 em; and pixel size, 18.6 em. Based on images of 150 slices, images of four different matrix sizes and nine different slice thicknesses were made using public domain software (NIH Image). The threshold value for image binarization, and the relation between pixel size and the slice thickness of an image used for two-dimensional and three-dimensional fractal analyses were studied. In addition, the box counting method was used for fractal analysis. One hundred forty-five in box counting was most suitable as the threshold value for image binarization on the 256 gray levels. The correlation coefficients between two-dimensional fractal dimensions of processed images and three-dimensional fractal dimensions of original images were more than 0.9 for pixel sizes < or =148.8 microm at a slice thickness of 1 mm, and < or =74.4 microm at one of 2 mm. In terms of the relation between the three-dimensional fractal dimension of processed images and three-dimensional fractal dimension of original images, when pixel size was less than 74.4 microm, a correlation coefficient of more than 0.9 was obtained even for the maximal slice thickness (1.74 mm) examined in this study.

Adult↗

Comparison of vertebral morphometry in the lumbar vertebrae by T1-weighted sagittal MRI and radiograph.

PURPOSE: In this study, we investigated the usefulness of T1-weighted sagittal MR images at the lumbar vertebrae in the vertebral morphometry, in comparison with lateral radiographs. SUBJECTS AND METHODS: The subjects were 42 men (mean age: 53.0 years) and 41 women (mean age: 57.9 years). Both MRI and radiography of the lumbar spine were performed within 1 month. The vertebral body heights and their ratios were measured by the semi-automatic measuring system. The frequency of a vertebral fracture and the absolute value of vertebral body height in both morphometry were compared. RESULTS: Based on the criteria for prevalent vertebral fracture using vertebral height ratios, the vertebrae were classified into four groups. Group 1 was defined as the vertebrae without fracture (n=347 vertebrae). Groups 2-4 were defined as the vertebrae with fracture; Group 2 by both MRI and X-ray morphometry (n=17), Group 3 by MRI morphometry alone (n=17), and Group 4 by X-ray morphometry alone (n=4). The rate of prevalent vertebral fracture diagnosed by MRI morphometry (8.8%) was higher than that by X-ray morphometry (5.5%). In Group 1, the values of anterior and posterior vertebral height obtained by MRI morphometry were greater than those obtained by X-ray morphometry. On the other hand, the values of central vertebral height obtained by MRI morphometry were smaller than those obtained by X-ray morphometry. CONCLUSION: Severe biconcave deformity of vertebra can be detected by both MRI and X-ray morphometry, although mild biconcave deformity can be detected only by MRI morphometry.

Adolescent↗

Usefulness of noise adaptive non-linear gaussian filter in FDG-PET study.

OBJECTIVE: In positron emission tomography (PET) studies, shortening transmission (TR) scan time can improve patient comfort and increase scanner throughput. However, PET images from short TR scans may be degraded due to the statistical noise included in the TR image. The purpose of this study was to apply non-linear Gaussian (NLG) and noise adaptive NLG (ANLG) filters to TR images, and to evaluate the extent of noise reduction by the ANLG filter in comparison with that by the NLG filter using phantom and clinical studies. METHODS: In phantom studies, pool phantoms of various diameters and injected doses of 2-deoxy-2-[18F]fluoro-D-glucose (FDG) were used and the coefficients of variation (CVs) of the counts in the TR images processed with the NLG and ANLG filters were compared. In clinical studies, two normal volunteers and 13 patients with tumors were studied. In volunteer studies, the CV values in the liver were compared. In patient studies, the standardized uptake values (SUVs) of tumors in the emission images were obtained after processing the TR images using the NLG and ANLG filters. RESULTS: In phantom studies, the CV values in the TR images processed with the ANLG filter were smaller than those in the images processed with the NLG filter. When using the ANLG filter, their dependency on the phantom size, injected dose of FDG and TR scan time was smaller than when using the NLG filter. In volunteer studies, the CV values in the images processed with the ANLG filter were smaller than those in the images processed with the NLG filter, and were almost constant regardless of the TR scan time. In patient studies, there was an excellent correlation between the SUVs obtained from the images with a TR scan time of 7 min processed with the NLG filter (x) and those obtained from the images with a TR scan time of 4 min processed with the ANLG filter (y) (r = 0.995, y = 1.034x - 0.075). CONCLUSIONS: Our results suggest that the ANLG filter is effective and useful for noise reduction in TR images and shortening TR scan time while maintaining the quantitative accuracy of FDG-PET studies.

Adult↗

Clinical potentials of the prototype 256-detector row CT-scanner.

RATIONALE AND OBJECTIVES: To evaluate clinical potentials of the 256-detector row computed tomography (CT) in healthy volunteers. MATERIALS AND METHODS: Eight healthy males (22-63 years) participated in the present study. They underwent a noncontrast-enhanced examination with a contiguous axial scan mode either for head, chest, abdomen, or pelvis. Dose was the same as routinely used for multislice CT examinations. Image quality was interpreted by three board-certified radiologists. RESULTS: With the 256-detector row CT, 0.5-0.8 mm isotropic volumetric data could be acquired in one rotation. Main promising findings are as follows. Three-dimensional structures were visualized clearly in the multiple planes without secondary reconstruction, whereas the axial images had nearly the same image quality as conventional CT. Shading or streak artifacts were observed at the edge of the scan region. The latter are also known as Feldkamp artifacts. Coronal chest images showed a motion artifact from the heart beating. CONCLUSION: The 256-detector row CT promises to be useful in clinical applications with its ability to provide three-dimensional visualization of fine structures. The Feldkamp artifacts observed did not generally affect interpretation of images. Investigations are now continuing on image correction along the craniocaudal direction to improve the overall image quality.

Adult↗

Determination of transverse relaxation rate for estimating iron deposits in central nervous system.

To determine the amount of iron deposits in the basal ganglia, we examined 13 healthy volunteers with a 1.5 T MRI system using three transverse relaxation rates measured with two sequences. The transverse relaxation rates comprise the reversible contribution (R2') and irreversible contribution (R2) to a phase-reversal 180 degrees -pulse sequence. The transverse relaxation rates with the estimated iron indicated that both R2 and R2' had a robust relationship with brain iron level as determined from published post mortem data. This was the case only when the analyses are limited to the subcortical gray matter regions, however. R2' was affected by macroscopic magnetic field inhomogeneity arising from the skull bases, so that it was less robust for estimating the amount of iron deposits in the basal ganglia.