PubMed Health⌕ Search

Biomedical subjects

Kildong Hwang

Publications and source records attributed to Kildong Hwang.

4 recordsLinked to original sources

Plane-wave fluorescence tomography with adaptive finite elements.

We present three-dimensional fluorescence yield tomography of a tissue phantom in a noncontact reflectance imaging setup. The method employs planar illumination with modulated light and frequency domain fluorescence measurements made on the illumination plane. An adaptive finite-element algorithm is used to handle the ill-posed and computationally demanding inverse image reconstruction problem. Tomographic images of fluorescent targets buried at 1-2 cm depths from the illumination surface demonstrate the feasibility of fluorescence tomography from reflectance tomography in clinically relevant tissue volumes.

Algorithms↗

Fully adaptive FEM based fluorescence optical tomography from time-dependent measurements with area illumination and detection.

Using an area-illumination and area-detection scheme, we acquire fluorescence frequency domain measurements from a tissue phantom with an embedded fluorescent target and obtain tomographic reconstructions of the interior fluorescence absorption map with an adaptive finite element based scheme. The tissue phantom consisted of a clear acrylic cubic box (512 ml) filled with 1% Liposyn solution, while the fluorescent targets were 5 mm diameter glass bulbs filled with 1 microM Indocyanine Green dye solution in 1% Liposyn. Frequency domain area illumination and detection employed a planar excitation source using an expanded intensity modulated (100 MHz) 785 nm diode laser light and a gain modulated image intensified charge coupled device camera, respectively. The excitation pattern was characterized by isolating the singly scattered component with cross polarizers and was input into a dual adaptive finite element-based scheme for three dimensional reconstructions of fluorescent targets embedded beneath the phantom surface. Adaptive mesh refinement techniques allowed efficient simulation of the incident excitation light and the reconstruction of fluorescent targets buried at the depths of 1 and 2 cm. The results demonstrate the first clinically relevant noncontact fluorescence tomography with adaptive finite element methods.

Algorithms↗

Specific ion-dependent attraction and phase behavior of polymer-coated colloids.

This paper presents results demonstrating the role of temperature and specific ions in mediating attraction between polymer-coated colloids and determining their equilibrium phase behavior. In particular, theoretical predictions of continuum van der Waals attraction between poly(ethylene oxide)-poly(propylene oxide)-poly(ethylene oxide) (PEO-PPO-PEO)-coated polystyrene colloids are used to explain measured temperature and specific ion-dependent fluid-gel transitions in dispersions of these particles. Building on previous studies of PEO-PPO-PEO-coated polystyrene colloids dispersed in aqueous NaCl media, this work reports rheologically measured fluid-gel transitions as a function of temperature and NaCl/MgSO4 composition. Adhesive-sphere predictions of percolation thresholds are fit to measured fluid-gel data by allowing the adsorbed copolymer layer thickness as a single adjustable parameter. This allows the attraction between the PEO-PPO-PEO layers to be interpreted as a function of temperature and NaCl/MgSO4 composition. Quantitative predictions of a polymeric van der Waals attraction associated with the layer collapse in diminishing solvent conditions provides a simple mechanism for explaining the measured fluid-gel data as a dynamic percolation transition. Ultimately, this work identifies the importance of continuum polymeric van der Waals attraction for explaining specific ion-dependent phenomena.

Journal Article↗

Improved excitation light rejection enhances small-animal fluorescent optical imaging.

Small-animal fluorescence-enhanced imaging involves the detection of weak fluorescent signals emanating from nanomolar to picomolar concentrations of exogenous or endogenously produced fluorophore concurrent with the rejection of an overwhelmingly large component of backscattered excitation light. The elimination of the back-reflected excitation light of the collected signal remains a major and often unrecognized challenge for further reducing the noise floor and increasing sensitivity of small-animal fluorescence imaging. Herein, we show that the combination of three-cavity interference and holographic super notch filters with appropriate imaging lenses to collimate light improves rejection of excitation light, enabling more accurate imaging. To assess excitation leakage, the "out-of-band (S(lambda x))" to "in-band (S(lambda m) - S(lambda x))" signal ratio from phantom studies and the target-to-background ratio (TBR) from in vivo animal imaging was acquired with and without collimating optics. The addition of collimating optics resulted in a 51% to 75% reduction in the ratio of (S(lambda x))/(S(lambda m) - S(lambda x)) for the phantom studies and an improvement of TBR from 11% to 31% and of signal-to-noise ratio from 11% to 142% for an integrin-targeting conjugate in human glioma xenografts.

Animals↗