A flexible transcutaneous oxygen sensor using polymer membranes.

A wearable and flexible oxygen sensor for transcutaneous blood gas monitoring was fabricated and tested. The sensor has a laminar film-like structure, which was fabricated by pouching KCl electrolyte solution by both non-permeable (metal weldable) sheet and gas-permeable membrane with Pt- and Ag/AgCl-electrodes patterned using microfabrication process. The electrolyte solution was fixed only by heat-sealing the edges of the weldable membranes without any chemical adhesives. The wearable oxygen sensor (thickness: 84 mum) was applied to the electrochemical measurement with a constant potential of -600 mV vs. Ag/AgCl, thus obtaining the calibration range to dissolved oxygen (DO) from 0.0 to 7.0 mg/l with a correlation coefficient of 0.998 and the quick response time (53.4 s to 90% of a steady-state current), which operate similarly to a commercially available oxygen electrode. The sensor was also utilized to transcutaneous oxygen monitoring for healthy human subject. The sensing region of the wearable oxygen sensor was attached onto the forearm-skin surface of the subject inhaling various concentrations of oxygen. As a result of physiological application, the output current was varied from -6.2 microA to -7.8 microA within 2 min when the concentration of inhaling oxygen was changed from atmospheric air to 60% oxygen. Thus, the transcutaneous oxygen was successfully monitored without any inconveniences such as skin inflammation, etc.

Biosensing Techniques↗

Rapid direct determination using combined separation by prepared immunomagnetic and flow cytometry of Flavobacterium psychrophilum.

Flavobacterium psychrophilum, the causative agent of bacterial cold-water disease (BCWD), was originally isolated from coho salmon Oncorhychus kisutch in the USA. Bacterial cold-water disease has since been spreading throughout Japan and has caused serious damage to populations of ayu Plecoglossus altivel in many farms and rivers. The rapid method of detecting for F. psuchrophilum is requested, however, traditional methods are laborious because of complicated assay procedures. In this study, a rapid method of detecting F. psychrophilum was developed using a modified method of flow cytometry (FCM) analysis and immunomagnetic separation (IMS). Magnetic iron, in small particles, was prepared by the reaction of a mixture of ferric and ferrous ions under alkaline conditions. The particles were coated with antiserum against F. psychrophilum by dextran. Polyclonal antibodies (anti-F. psychrophilum) conjugated with fluorescein isothiocyanate (FITC) were reacted with F. psychrophilum, and then prepared immunomagnetic were applied using IMS, followed by FCM determination. A good correlation was observed between the cell numbers determined by the FCM method and the traditional method in the range of 10(2)-10(8) cells ml(-1). The FCM analysis could count cells within 1min, and the total analysis time, including sample preparation, was less than 2 h.

Cell Separation↗

A flexible and wearable glucose sensor based on functional polymers with soft-MEMS techniques.

A novel biosensor for glucose measurement using functional polymers was fabricated and tested. The biosensor utilizes the physical and chemical functions of hydrophobic polydimethyl siloxane (PDMS) and hydrophilic 2-methacryloyloxyethyl phosphorylcholine (MPC) copolymerized with dodecyl methacrylate (DMA). The glucose sensor was constructed by immobilizing glucose oxidase (GOD) onto a flexible hydrogen peroxide electrode (Pt working electrode and Ag/AgCl counter/reference electrode). The electrodes were fabricated using microelectromechanical systems (MEMS) techniques onto those functional polymers. The sensor showed novel functions of flexibility and it was stretchable so that the sensor could normally work when it was released after expanding to 120% longer than that of normal length. Also, basic characteristics of the sensor were evaluated. The output current of the hydrogen peroxide electrode was linearly related to the hydrogen peroxide concentration in a range of 0.20-2.50 mmol/l, with a correlation coefficient of 0.998. GOD was then immobilized onto the surface of the sensor using MPC polymer. In this case, the current output of the glucose sensor related to the glucose level over a range of 0.06-2.00 mmol/l, with a correlation coefficient of 0.997. The calibration range includes the reported concentration of tear glucose in normal human subject (0.14 mmol/l).

Blood Glucose Self-Monitoring↗

Bioelectronic sniffers for ethanol and acetaldehyde in breath air after drinking.

Two kinds of bioelectronic gas sensors (bio-sniffer) incorporating alcohol oxidase (AOD) and aldehyde dehydrogenase (ALDH) were developed for the convenient analysis of ethanol and acetaldehyde in expired gas, respectively. The sniffer devices for gaseous ethanol and acetaldehyde were constructed by immobilizing enzyme on electrodes covered with filter paper and hydrophilic PTFE membrane, respectively. The AOD and ALDH sniffers were used in the gas phase to measure ethanol vapor from 1.0 to 500 ppm, and acetaldehyde from 0.11 to 10 ppm covering the concentration range encountered in breath after alcohol consumption. Both bio-sniffers displayed good gas selectivity which was attributed to the substrate specificity of the relevant enzymes (AOD and ALDH) as gas recognition material. From the results of physiological application, the bio-sniffers could monitor the concentration changes in breath ethanol and acetaldehyde after drinking. The ethanol and acetaldehyde concentrations in expired air from ALDH2 [-] (aldehyde dehydrogenase type 2 negative) subjects were higher than that of the ALDH2 [+] (positive) subjects. The results indicated that the lower activity of ALDH2 induced an adverse effect on ethanol metabolism, leading to ethanol and acetaldehyde remaining in the human body, even human expired air.

Acetaldehyde↗

Optical bio-sniffer for ethanol vapor using an oxygen-sensitive optical fiber.

An optical bio-sniffer for ethanol was constructed by immobilizing alcohol oxidase (AOD) onto a tip of a fiber optic oxygen sensor with a tube-ring, using an oxygen sensitive ruthenium organic complex (excitation, 470 nm; fluorescent, 600 nm). A reaction unit for circulating buffer solution was applied to the tip of the device. After the experiment in the liquid phase, the sniffer-device was applied for gas analysis using a gas flow measurement system with a gas generator. The optical device was applied to detect the oxygen consumption induced by AOD enzymatic reaction with alcohol application. The sensor in the liquid phase was used to measure ethanol solution from 0.50 to 9.09 mmol/l. Then, the bio-sniffer was calibrated against ethanol vapor from 0.71 to 51.49 ppm with good gas-selectivity based on the AOD substrate specificity. The bio-sniffer with the reaction unit was also used to monitor the concentration change of gaseous ethanol by rinsing and cleaning the fiber tip and the enzyme membrane with buffer solution.

Alcohol Oxidoreductases↗

Optical-transparent and flexible glucose sensor with ITO electrode.

The glucose sensor was constructed by immobilizing glucose oxidase (GOD) with glutaraldehyde solution onto the sensitive area of the transparent oxygen electrode. The oxygen electrode was fabricated by sealing KCl electrolyte solution including the Indium-Tin Oxide (ITO)-electrode with both metal-weldable film and gas-permeable membrane coated with Ag/AgCl electrode. The sensor behavior was evaluated using standard glucose solutions in a batch measurement system with a computer-controlled potentiostat at a reduction potential of -900 mV. The sensor device has flexible structure and good optical transparency (less than 0.6 abs) at the visible wavelength from 400 to 700 nm. The sensor was possible to be used for measuring glucose from 0.06 to 1.24 mmol/l (correlation coefficient: 0.999), including the reported concentration of tear glucose in normal (0.14 mmol/l), with good reproducibility.

Adsorption↗