PubMed Health⌕ Search

Biomedical subjects

Kwang-Pill Lee

Publications and source records attributed to Kwang-Pill Lee.

16 recordsLinked to original sources

Electrospun poly(vinylidene fluoride)/poly(aminophenylboronic acid) composite nanofibrous membrane as a novel glucose sensor.

Electrospinning was used to prepare the nanofibrous membrane (NFM) of the composite comprising poly(vinylidene fluoride) and poly(aminophenylboronic acid) (PVdF/PAPBA-NFM). The PVdF/PAPBA-NFM displayed an excellent linear response to the detection of glucose for the concentration range of 1 to 15mM with a response time of less than 6s. Further experiments on amperometric sensing of glucose were performed in the presence of interferents such as uric acid, ascorbic acid, acetaminophen, fructose, mannose, etc. using PVdF/PAPBA-NFM. The interferents did not give significant overlapping current signal during the determination of glucose. Also, PVdF/PAPBA-NFM possesses better reproducibility toward glucose detection and storage stability.

Biosensing Techniques↗

Fabrication and electrocatalysis of self-assembly directed gold nanoparticles anchored carbon nanotubes modified electrode.

A self-assembly directed approach was adopted to modify glassy carbon electrode (GC) with gold nanoparticles incorporation and the electrocatalytic performance of self-assembly modified electrode, GC/SA-Au-ME was critically evaluated for the oxidation of ascorbic acid (AA). The modification involves the dispersion of multi-wall carbon nanotube (MWNT) and an inclusion complex, beta-cyclodextrin-4-aminothiophenol on the surface of GC electrode in the presence of cetyltrimethylammonium bromide (CTAB). Gold nanoparticles were deposited into the self-assembled sites to fabricate the modified electrode, GC/SA-Au-ME. Another electrode (GC-Au-ME) was fabricated under similar conditions in the absence of CTAB. The electrocatalytic activity of the modified electrodes (GC/SA-Au-ME and GC-Au-ME) towards the oxidation of AA was critically compared. Cyclic voltammetry, chronoamperometry, and double potential chronoamperometry were used to evaluate the characteristics of the modified electrodes. The self-assembled electrode (GC/SA-Au-ME) shows excellent electrocatalytic activity over the other electrode, GC-Au-ME. Augmented current response, faster electron transfer kinetics (with a rate constant for electron transfer process as 3.25 x 10(4) cm3 mol(-1) s(-1)), linear range of response for the analyte (1-50 mM with an extended detection limit to 1 microM), better sensitivity, and selectivity were witnessed for the self-assembly directed modified electrode.

Catalysis↗

Nanostructuring of poly(diphenylamine) inside the galleries of montmorillonite organo clay through self-assembly approach.

Hollow spheres of poly(diphenylamine) (PDPA) was prepared by confining PDPA in the galleries of montmorillonite organo clay modified with organoammonium cations (MMT). At first instant, diphenylamine (DPA) was loaded into the galleries of MMT and subjected to subsequent oxidative polymerization to form PDPA. beta-naphthalene sulfonic acid (NSA) was used as medium to influence self-assembly of DPA inside the galleries of MMT. Polymerization of self assembled structure resulted hollow spheres of PDPA inside galleries of MMT. X-ray diffraction analysis (XRD), field emission transmission electron microscopy (FETEM), Fourier transform infra-red spectroscopy (FT-IR) and thermogravimetric analysis (TGA) were used to characterize the composites. Transmission emission microscopy of the composite shows the hollow spherical morphology of PDPA. FT-IR, UV-Visible spectroscopy, conductivity measurement and X-ray photoelectron spectroscopy were used to characterize the PDPA extracted from MMT galleries. PDPA extracted from MMT galleries was found to have difference in electronic property than PDPA formed by the conventional method, due to the confinement effect.

Bentonite↗

Rapid separation of Sudan dyes by reverse-phase high performance liquid chromatography through statistically designed experiments.

Central composite design (CCD) was effectively employed to decide optimum conditions for the rapid separation of Sudan dyes using reverse-phase high performance liquid chromatography (HPLC). Twenty experiments, taking the minimum resolution and retention time of the last eluted peak as the responses with three important factors, mobile phase composition, flow rate and column temperature, were used to design a mathematical model. The experimental responses were fitted into a second order polynomial and used to predict the optimum conditions for the effective separation of the studied compounds. Further, chromatographic separation efficiency was tested through generation of Pareto-optimal points. The validity of using modified central composite design in predicting the optimization conditions was experimentally verified. The optimum conditions were: acetonitrile/0.1% aqueous formic acid (90/10, %v/v) as the mobile phase, at a flow rate of 1.2mL/min and column temperature of 15 degrees C, respectively. While using this optimum condition, baseline separation with a minimum resolution more than 1.5 and a separation time of less than 6min were achieved.

Acetonitriles↗

Retention behavior of C1-C6 aliphatic monoamines on anion-exchange and polymethacrylate resins with heptylamine as eluent.

Retention behavior of C1-C6, aliphatic monoamines (methylamine, ethylamine, propylamine, butylamine, amylamine and hexylamine) on columns (150 mm x 6 mm i.d.) packed with various anion-exchange resins (styrene-divinylbenzene (PS-DVB) copolymer-based strongly basic anion-exchange resin: TSKgel SAX, polymethacrylate-based strongly basic anion-exchange resin: TSKgel SuperQ-5PW and polymethacrylate-based weakly basic anion-exchange resin: TSKgel DEAE-5PW) and unfunctionized polymethacrylate resins (TSKgel G5000PW and TSKgel G3000PWXL) was investigated with basic solutions (sodium hydroxide and heptylamine) as the eluents. Due to strongly electrostatic repulsion (ion-exclusion effect) between these anion-exchange resins and these amines, peak resolution between these amines on these anion-exchange resin columns was unsatisfactory with both sodium hydroxide and heptylamine as the eluents. In contrast, these polymethacrylate resins were successfully applied as the stationary phases for the separation of these C1-C6 amines with heptylamine as eluent, because of both small hydrophobicity and small cation-exchange ability of these resins. Excellent simultaneous separation, highly sensitive conductimetric detection and symmetrical peaks for these C1-C6 amines were achieved on the TSKgel G3000PWXL column in 35 min with 5 mM heptylamine at pH 11.1 as the eluent.

Amines↗

Comparative study on the chiral separation of phenyl alcohols by capillary electrophoresis and liquid chromatography.

Structurally related phenyl alcohols were separated by capillary electrophoresis and liquid chromatography. A statistical experimental design was used in order to optimize the main electrophoretic parameters such as pH, concentration of selector and separation voltage in capillary electrophoresis (CE). Response surfaces were derived using the mathematical model and used for a selection of the optimal experimental conditions. Concentration of the chiral selector, the distance between the aromatic group and asymmetric center of the analytes, were identified as the factors influencing the complexation, selectivity and resolution. Experiments were also performed by high-performance liquid chromatography (HPLC) and the results of CE and HPLC were compared.

Benzyl Alcohols↗

Split flow and bypass flow systems for monolithic capillary columns in liquid chromatography.

Split flow and bypass flow systems were assembled using Nano Y Connectors with low dead volume commercially available for capillary liquid chromatography (LC). The split ratio could be controlled by changing the dimension of restriction tubing and applied back pressure to the restriction tubing. The split flow system allowed us to use valve injectors and pumps commercially available for capillary LC. The reproducibility of the present split flow system was acceptable. The relative standard deviation for six successive measurements was 0.4% for the retention time, whereas that for the peak height and peak area was 1-3% depending on the analytes. The bypass flow system uses two Nano Y Connectors, where the eluent split at the first Nano Y Connector, which is located in the inlet of the separation column, is merged again into the effluent from the column at the second Nano Y Connector. The bypass flow system could avoid on-column detection and allowed us to use flow cells, leading to an approximate three times improvement in signal-to-noise. The present flow systems were evaluated by using aromatic hydrocarbons and alkylbenzenes as test analytes.

Chromatography, Liquid↗

Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent.

The application of various hydrophilic cation-exchange resins for high-performance liquid chromatography (sulfonated silica gel: TSKgel SP-2SW, carboxylated silica gel: TSKgel CM-2SW, sulfonated polymethacrylate resin: TSKgel SP-5PW, carboxylated polymethacrylate resins: TSKgel CM-5PW and TSKgel OA-Pak A) as stationary phases in ion-exclusion chromatography for C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, butyric, isovaleric, valeric, isocaproic, caproic, 2-methylhexanoic and heptanoic acids) and benzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic, salicylic acids and phenol) was carried out using diluted sulfuric acid as the eluent. Silica-based cation-exchange resins (TSKgel SP-2SW and TSKgel CM-2SW) were very suitable for the ion-exclusion chromatographic separation of these benzenecarboxylic acids. Excellent simultaneous separation of these benzenecarboxylic acids was achieved on a TSKgel SP-2SW column (150 x 6 mm I.D.) in 17 min using a 2.5 mM sulfuric acid at pH 2.4 as the eluent. Polymethacrylate-based cation-exchange resins (TSKgel SP-5PW, TSKgel CM-5PW and TSKgel OA-Pak A) acted as advanced stationary phases for the ion-exclusion chromatographic separation of these C1-C7 aliphatic carboxylic acids. Excellent simultaneous separation of these C1-C7 acids was achieved on a TSKgel CM-5PW column (150 x 6 mm I.D.) in 32 min using a 0.05 mM sulfuric acid at pH 4.0 as the eluent.

Benzene Derivatives↗

Comparison of monomeric and polymeric chiral stationary phases.

Two-type polymeric chiral stationary phases (pCSPs) were prepared by surface grafting of chiral acryl-type monomers on a silica gel surface modified with 3-(trimethoxysilyl)propylmethacrylate. The prepared pCSPs were characterized by IR, Fr-Raman, scanning electron microscopy, and elemental analysis. In addition, two-type monomeric chiral stationary phases (mCSPs) were also prepared. The racemic analytes were separated using the prepared mCSPs and pCSPs. The separation factor (alpha) and capacity factor (k1) of the racemic analytes for the pCSP and mCSP were compared. The alpha and k1 values of the mCSP were higher than those of the pCSP.

Chromatography, Liquid↗

Enantioseparation of racemic N-acylarylalkylamines on various amino alcohol derived tau-acidic chiral stationary phases.

Five tau-acidic chiral stationary phases (CSPs), CSP 4, CSP 5, CSP 6, CSP 7 and CSP 8, were prepared by connecting the N-(3,5-dimethylbenzoyl) derivative of (R)-alaninol, (S)-leucinol, (1S,2R)-ephedrine and (S)-tert-leucinol and the O-(3,5-dinitrobenzoyl) derivative of (R)-phenylglycinol to silica gel through a carbamate or urea linkage. The CSPs were applied to the resolution of various racemic N-acyl-1-naphthylaminoalkanes by chiral HPLC, and the chromatographic resolution results were compared with those of previously reported CSPs (CSP 2, CSP 3), which are derived from N-(3,5-dinitrobenzoyl)-(1S,2R)-norephedrine and N-(3,5-dinitrobenzoyl-(R)-phenylglycinol. Based on a comparison of the resolution results for each CSP, the role of each functional group on the five chiral selectors is explained.

Amines↗

Separation of proteins on polymeric stationary phases grafted with various amine groups.

Six polymeric stationary phases with various amine groups were prepared by surface grafting of glycidyl methacrylate on silica gel surface and its subsequent amination. The six kinds of amines, namely, triethylamine, diethylamine, ethylenediamine (EDA), hexaethylenediamine (HEDA), diethylenetriamine (DETA) and triethylenetetraamine (TETA) were used in this study. The separation of bovine serum albumin (BSA) and chicken egg albumin (CEA) on the polymeric stationary phase with various amines was investigated. The affinity degree of BSA was higher than CEA for the EDA, HEDA and DETA columns, whereas the affinity degree of CEA was higher than BSA for the TETA column.

Amines↗

Surface grafting of glycidyl methacrylate on silica gel and polyethylene beads.

Surface grafting of glycidyl methacrylate (GMA) on silica gel and a polyethylene bead was performed by radical polymerization and radiation-induced polymerization, respectively, in order to improve softness. Subsequently, diethylene triamine (DETA), triethylene tetraamine (TETA), and iminodiacetic acid (IDA) were introduced to the grafted GMA for use as affinity columns. The efficiency of the affinity column was investigated by use of bovine serum albumin (BSA) and hemoglobin (Hb) as model proteins. The affinity degree of BSA was higher than Hb for the DETA and TETA column, whereas the affinity degree of Hb was higher than BSA for the IDA column supported by silica gel. The affinity degree of BSA was higher than Hb for the DETA and TTA column supported by polyethylene (PE) beads.

Amines↗

Pressure-controlled on-column injection method for microcolumn liquid chromatography.

A pressure-controlled on-column injection method was developed for microcolumn liquid chromatography. The system was assembled from a syringe pump, a Model M-445 Six-Way Micro Selection Valve, a separation column and a UV detector. The injection volume could be regulated by changing the applied pressure and/or the sample loading time. The system was evaluated in the ion-exchange mode. The system was applied to the determination of anions in river-water samples.

Journal Article↗

NMR studies of chiral discrimination relevant to the enantioseparation of N-acylarylalkylamines by an (R)-phenylglycinol-derived chiral selector.

Recently, it was reported that the chiral recognition ability of (R)-N-3,5-dinitrobenzoyl phenylglycinol derivative was examined as a new HPLC chiral stationary phase (CSP 1) for the resolution of racemic N-acylnaphthylalkylamines. However, the mechanism of chiral discrimination on the CSP remained elusive until now. In this study, a spectroscopic investigation of the chiral discrimination mechanism of CSP 1 was undertaken using mixtures of (R)-N-3,5-dinitrobenzoyl phenylglycinol-derived chiral selector (2) and each of the enantiomers of N-acylnaphthylalkylamines (3) by NMR study. First, the differences in free energy changes (DeltaDeltaG) upon diastereomeric complexation in solution between the complex of each isomer with chiral selector 2 by NMR titration were calculated. The values were then compared with those estimated by chiral HPLC. The chemical shift changes of each proton on the chiral selector and analytes were also checked and it was found that the chemical shift changes decreased continuously as the acyl group on analytes increased in length. This observation was consistent with the HPLC data. From these experimental results, the interaction mechanism of chiral discrimination between the chiral selector and the analytes is more precisely explained.

Journal Article↗

Preparation and characterization of polyalkene membranes modified with four different ion-exchange groups by radiation-induced graft polymerization.

Three different cation-exchange membranes with carboxylic acid, phosphoric acid, and sulfonic acid groups, and one anion-exchange membrane with a triethylamine group were prepared by radiation-induced graft polymerization. The maximum capacities of the carboxylic acid, phosphoric acid, sulfonic acid, and triethylamine groups were 3.0, 2.30, 2.43, and 1.42 mmol/g, respectively. The physico-chemical properties of the polyalkene non-woven fabric membrane with four different ion-exchange groups were examined by thermogravimetric analysis, X-ray photoelectron spectrometry (XPS), and scanning electron microscopy. The prepared ion-exchange membrane was applied to the removal of terephthalic acid in dyeing wastewater.

Carboxylic Acids↗

Preparation and characterization of cyclodextrin polymer and its high-performance liquid-chromatography stationary phase.

Cyclodextrin (CD) polymers were synthesized from the reaction of native CDs with a hexamethylene diisocyanate (HDI) compound in a dried DMF solution. The obtained CD polymer contained a range of 8-14% N due to HDI by elemental analysis. The physical and chemical properties of the CD polymers were characterized by IR, solid state 13C NMR, TGA, and DSC, respectively. An HPLC column was prepared using the CD polymer with a carbamate linker by a slurry method. Separation of the phenol isomers was conducted using the CD polymer stationary phase and CD by HPLC. Furthermore, an inclusion complex of the phenol isomer was studied by FT-Raman spectroscopy. From the HPLC and FT-Raman results, inclusion phenomena of o-, m-, and p-nitrophenol onto CD and CD polymers were analyzed.

Calorimetry, Differential Scanning↗