PubMed Health⌕ Search

Biomedical subjects

Kyle J Myers

Publications and source records attributed to Kyle J Myers.

6 recordsLinked to original sources

Toward objective and quantitative evaluation of imaging systems using images of phantoms.

The use of imaging phantoms is a common method of evaluating image quality in the clinical setting. These evaluations rely on a subjective decision by a human observer with respect to the faintest detectable signal(s) in the image. Because of the variable and subjective nature of the human-observer scores, the evaluations manifest a lack of precision and a potential for bias. The advent of digital imaging systems with their inherent digital data provides the opportunity to use techniques that do not rely on human-observer decisions and thresholds. Using the digital data, signal-detection theory (SDT) provides the basis for more objective and quantitative evaluations which are independent of a human-observer decision threshold. In a SDT framework, the evaluation of imaging phantoms represents a "signal-known-exactly/background-known-exactly" ("SKE/ BKE") detection task. In this study, we compute the performance of prewhitening and nonprewhitening model observers in terms of the observer signal-to-noise ratio (SNR) for these "SK E/BKE" tasks. We apply the evaluation methods to a number of imaging systems. For example, we use data from a laboratory implementation of digital radiography and from a full-field digital mammography system in a clinical setting. In addition, we make a comparison of our methods to human-observer scoring of a set of digital images of the CDMAM phantom available from the internet (EUREF-European Reference Organization). In the latter case, we show a significant increase in the precision of the quantitative methods versus the variability in the scores from human observers on the same set of images. As regards bias, the performance of a model observer estimated from a finite data set is known to be biased. In this study, we minimize the bias and estimate the variance of the observer SNR using statistical resampling techniques, namely, "bootstrapping" and "shuffling" of the data sets. Our methods provide objective and quantitative evaluation of imaging systems with increased precision and reduced bias.

Algorithms↗

Singular-value decomposition for through-focus imaging systems.

Singular-value decomposition (SVD) of a linear imaging system gives information on the null and measurement components of object and image and provides a method for object reconstruction from image data. We apply SVD to through-focus imaging systems that produce several two-dimensional images of a three-dimensional object. Analytical expressions for the singular functions are derived in the geometrical approximation for a telecentric, laterally shift-invariant system linear in intensity. The modes are evaluated numerically, and their accuracy confirmed. Similarly, the modes are derived and evaluated for a continuous image representing the limit of a large number of image planes.

Journal Article↗

Objective assessment of image quality. IV. Application to adaptive optics.

The methodology of objective assessment, which defines image quality in terms of the performance of specific observers on specific tasks of interest, is extended to temporal sequences of images with random point spread functions and applied to adaptive imaging in astronomy. The tasks considered include both detection and estimation, and the observers are the optimal linear discriminant (Hotelling observer) and the optimal linear estimator (Wiener). A general theory of first- and second-order spatiotemporal statistics in adaptive optics is developed. It is shown that the covariance matrix can be rigorously decomposed into three terms representing the effect of measurement noise, random point spread function, and random nature of the astronomical scene. Figures of merit are developed, and computational methods are discussed.

Algorithms↗

Lubberts effect in columnar phosphors.

Noise transfer in granular x-ray imaging phosphor screens is not proportional to the square of the magnitude of the signal transfer when the transfer properties are considered for the entire screen thickness, unless appropriately weighted at each depth of interaction. This property, known as the Lubberts effect, has not yet been studied in columnar structured screens because of a lack of a generalized description of the depth-dependent light transport. In this paper, we investigate the signal and noise transfer characteristics of columnar phosphors used in digital mammography detectors using DETECT-II, an optical Monte Carlo light transport simulation code. We first validate our choice of optical parameters for the description of granular and columnar screens using published normalized modulation transfer (MTF) experimental data. Our calculations of MTF match empirically measured MTFs for a granular film/screen analog system, and for an indirect x-ray digital imaging system with CsI:Tl screen representative of digital mammography systems. Using the depth-dependent spread functions and collection efficiencies, we calculate the signal and noise transfer functions and the Lubberts fraction, which is the ratio of the signal transfer function to the noise transfer function, for different screen thicknesses of granular and columnar phosphors. We find that the Lubberts fraction of a 85 microm granular screen model corresponding to a Gd2O2S:Tb screen is similar to the fraction for a 100 microm columnar CsI:Tl screen.

Computer Simulation↗

An energy- and depth-dependent model for x-ray imaging.

In this paper, we model an x-ray imaging system, paying special attention to the energy- and depth-dependent characteristics of the inputs and interactions: x rays are polychromatic, interaction depth and conversion to optical photons is energy-dependent, optical scattering and the collection efficiency depend on the depth of interaction. The model we construct is a random function of the point process that begins with the distribution of x rays incident on the phosphor and ends with optical photons being detected by the active area of detector pixels to form an image. We show how the point-process representation can be used to calculate the characteristic statistics of the model. We then simulate a Gd2O2S:Tb phosphor, estimate its characteristic statistics, and proceed with a signal-detection experiment to investigate the impact of the pixel fill factor on detecting spherical calcifications (the signal). The two extremes possible from this experiment are that SNR2 does not change with fill factor or changes in proportion to fill factor. In our results, the impact of fill factor is between these extremes, and depends on the diameter of the signal.

Calcinosis↗

Signal detectability in digital radiography: spatial domain figures of merit.

The usefulness of Fourier-based measures of imaging performance has come into question for the evaluation of digital imaging systems. Figures of merit such as detective quantum efficiency (DQE) based on Fourier domain parameters are relevant for linear, shift-invariant systems with stationary noise. However, no digital imaging system is shift invariant, and realistic images do not satisfy the stationarity condition. Our methods for the task-based evaluation of imaging systems, based on signal detectability in the spatial domain, do not require such assumptions. We have computed the performance of ideal and quasi-ideal observers for the task of signal detection in digital radiography. Signal detectability in terms of an observer signal-to-noise-ratio (SNR) has been compared to results obtained from a Monte Carlo simulation of the digital image-acquisition process. The simulation incorporates the effects of random amplification and secondary quantum blur, integration over pixel area, and electronic noise. The observer figures of merit that have been previously shown to bracket human performance directly specify the usefulness of the images for the stated diagnostic task. In addition, the observer figures of merit give a task-dependent measure of imaging system efficiency in terms of the ratio of an output SNR2 to an input SNR2. Thus, the concept of "detective quantum efficiency" reappears in a natural way but based in the spatial domain and not dependent on shift invariance and stationarity assumptions. With respect to the optimum amount of system blur, our simulations indicate that under certain task-dependent conditions, large signals are fairly insensitive to blur in the x-ray transducer, while an optimum blur is found for small signals.

Humans↗