Abstract

Noise transfer in granular x-ray imaging phosphor screens is not proportional to the square of the magnitude of the signal transfer when the transfer properties are considered for the entire screen thickness, unless appropriately weighted at each depth of interaction. This property, known as the Lubberts effect, has not yet been studied in columnar structured screens because of a lack of a generalized description of the depth-dependent light transport. In this paper, we investigate the signal and noise transfer characteristics of columnar phosphors used in digital mammography detectors using DETECT-II, an optical Monte Carlo light transport simulation code. We first validate our choice of optical parameters for the description of granular and columnar screens using published normalized modulation transfer (MTF) experimental data. Our calculations of MTF match empirically measured MTFs for a granular film/screen analog system, and for an indirect x-ray digital imaging system with CsI:Tl screen representative of digital mammography systems. Using the depth-dependent spread functions and collection efficiencies, we calculate the signal and noise transfer functions and the Lubberts fraction, which is the ratio of the signal transfer function to the noise transfer function, for different screen thicknesses of granular and columnar phosphors. We find that the Lubberts fraction of a 85 microm granular screen model corresponding to a Gd2O2S:Tb screen is similar to the fraction for a 100 microm columnar CsI:Tl screen.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Aldo Badano, Robert M Gagne, Brandon D Gallas, Robert J Jennings, Jonathan S Boswell, Kyle J Myers. 2004. Lubberts effect in columnar phosphors.. https://doi.org/10.1118/1.1796151

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Generating correlated data for omics simulation.

Simulation of realistic omics data is a key input for benchmarking studies that help users obtain optimal computational pipelines. Omics data involves large numbers of measured features on each sample and these measures are generally correlated with each other. However, simulation too often ignores these correlations, perhaps due to computational and statistical hurdles of doing so. To alleviate this, we describe three approaches for generating omics-scale data with correlated measures which mimic real datasets. These approaches are all based on a Gaussian copula approach with a covariance matrix that decomposes into a diagonal part and a low-rank part. This decomposition allows for extremely efficient simulation, overcoming a hurdle for adoption of past methods. We use these approaches to demonstrate the importance of including correlation in two benchmarking applications. First, we show that variance of results from the popular DESeq2 method increases when dependence is included. Second, we demonstrate that CYCLOPS, a method for inferring circadian time of collection from transcriptomics, improves in performance when given gene-gene dependencies in some circumstances. We provide an R package, dependentsimr, that has efficient implementations of these methods and can generate dependent data with arbitrary marginal distributions, including discrete (binary, ordered categorical, Poisson, negative binomial), continuous (normal), or with an empirical distribution.

Computer Simulation↗

Addressing current challenges in cancer immunotherapy with mathematical and computational modelling.

The goal of cancer immunotherapy is to boost a patient's immune response to a tumour. Yet, the design of an effective immunotherapy is complicated by various factors, including a potentially immunosuppressive tumour microenvironment, immune-modulating effects of conventional treatments and therapy-related toxicities. These complexities can be incorporated into mathematical and computational models of cancer immunotherapy that can then be used to aid in rational therapy design. In this review, we survey modelling approaches under the umbrella of the major challenges facing immunotherapy development, which encompass tumour classification, optimal treatment scheduling and combination therapy design. Although overlapping, each challenge has presented unique opportunities for modellers to make contributions using analytical and numerical analysis of model outcomes, as well as optimization algorithms. We discuss several examples of models that have grown in complexity as more biological information has become available, showcasing how model development is a dynamic process interlinked with the rapid advances in tumour-immune biology. We conclude the review with recommendations for modellers both with respect to methodology and biological direction that might help keep modellers at the forefront of cancer immunotherapy development.

Computer Simulation↗

Degradation of supercoiled plasmid DNA within a capillary device.

Supercoiled plasmid DNA is susceptible to fluid stress in large-scale manufacturing processes. A capillary device was used to generate controlled shear conditions and the effects of different stresses on plasmid DNA structure were investigated. Computational fluid dynamics (CFD) analysis was employed to characterize the flow environment in the capillary device and different analytical techniques were used to quantify the DNA breakage. It was found that the degradation of plasmid DNA occurred at the entrance of the capillary and that the shear stress within the capillary did not affect the DNA structure. The degradation rate of plasmids was well correlated with the average elongational strain rate or the pressure drop at the entrance region. The conclusion may also be drawn that laminar shear stress does not play a significant role in plasmid DNA degradation.

Computer Simulation↗