PubMed Health⌕ Search

Biomedical subjects

L Claes

Publications and source records attributed to L Claes.

At least 73 records · Page 4Linked to original sources

Effect of an internal fixator and a bone graft on intersegmental spinal motion and intradiscal pressure in the adjacent regions.

Stabilizing a lumbar spine with an implant alters the mechanical properties of the bridged region. In order to determine whether this procedure is associated with higher loads in the adjacent segments, seven lumbar cadaver spines were mounted in a spine tester and loaded with pure moments of flexion/extension, left and right lateral bending, and left and right axial rotation. The material studied comprised intact lumbar spines, intact spines with bisegmental internal spinal fixators, and postcorpectomy spines both with a graft and fixators and with fixators alone. Intradiscal pressures and intersegmental motion were measured at all levels. In the bridged region, these parameters were strongly affected by an internal fixator. In most cases, the effect was small in the regions above and below the fixators. Highly significant differences in these regions (P<0.01) were far below the interspecimen range. We did not find any case where both intradiscal pressure changes and intersegmental motion showed highly significantly differences in the regions adjacent to the bridged one. Our results suggest that disc degeneration, which is sometimes found at the level directly above and below the fixators, is not caused by mechanical factors.

Adult↗

Resistance of the lumbar spine against axial compression forces after implantation of three different posterior lumbar interbody cages.

BACKGROUND: The aim of using interbody fusion cages is to distract the degeneratively decreased disc height to decompress the neural structures in the intervertebral foramina and allow bony fusion. Prerequisite for a successful fusion therapy is a high resistance against subsidence and breakage. METHOD: Three types of implants, a cylindrical threaded titanium cage (Ray) (1c), a bullet shaped PEEK cage (Stryker) (1a) and a rectangular titanium cage with an endplate anchorage device (Marquardt) (1b) were implanted in eight monosegmental lumbar spine specimens (L 2/3 and L 4/5). Each specimen underwent a cyclic loading test with 40000 cycles at a rate of 5 Hz. A cyclic axial compression force ranging from 200 Newton [N] to 1000 N was applied and the axial translation recorded simultaneously to determine the subsidence tendency. After this procedure the specimens were tested with a progressive axial force until breakage. FINDINGS: There were only small differences in the subsidence tendency for the three cage designs. The height reduction due to cyclic loading ranged between 0.9 mm (Marquardt), 1.2 mm (Stryker) and 1.4 mm (Ray). The median break force ranged from 5486 N (Marquardt), 8359 N (Stryker) to 8413 N (Ray). No correlation between bone mineral density and failure load could be detected. INTERPRETATION: Endplate preparation and cage design of the tested implants do not seem to influence the resistance of the segment against cyclic axial compression. The compression with a continuously increasing load revealed that an implant-bone failure is not to be expected in physiological limits for all three cage types.

Biomechanical Phenomena↗

The effect of micromovement on callus formation.

Micromovement at fracture sites is known to promote callus formation and bridging of the bony fragments. The present study was conducted to identify the suitable amount of micromovement, and to analyze the location and timing of callus proliferation. A standardized transverse osteotomy, in the right metatarsus of 32 sheep, was used as a fracture model. The osteotomy was externally fixed with a special ring fixator, which allowed axial micromovements of defined sizes. The animals were divided into four groups, with gaps of 2 mm and 6 mm, and micromovements of 0.3 mm and 0.7 mm, respectively. The labeling of new bone formation was performed by the intravenous injection of calcein green in the fourth week and tetracycline in the eighth week. Nine weeks postoperatively the sheep were killed. The explanted metatarsals were radiographed for the measurement of the periosteal callus area and were nondestructively loaded in a three-point bending test to determine their flexural rigidity. Histological analysis of undecalcified bone was performed in bone slices in the sagittal plane. Fluorescent green (callus formed in the fourth week) and yellow areas (callus formed in the eighth week) and the area of connective tissue were determined, using fluorescence microscopy. Bone formation was larger in the eighth week than that in the fourth week in all groups. In the fourth week, large micromovements in the small gap resulted in increased bone formation, whereas, for large gaps, the large micromovements diminished new bone formation. With large micromovement, the amount of newly formed bone within the gap decreased with increasing gap size, suggesting a delay of bone healing. Stimulation of new bone formation by micromovement was mainly effective in the early healing phase (4 weeks postoperatively). Large gaps showed the least new bone formation at the fracture site and the lowest flexural rigidity. From the histological analysis, it was found that the flexural rigidity correlated with the new bone area in the periosteal region.

Animals↗

Mechanical boundary conditions of fracture healing: borderline indications in the treatment of unreamed tibial nailing.

Unreamed nailing favors biology at the expense of the achievable mechanical stability. It is therefore of interest to define the limits of the clinical indications for this method. The extended usage of unreamed tibial nailing resulted in reports of an increased rate of complications, especially for the distal portion of the tibia. The goals of this work were to gain a thorough understanding of the load-sharing mechanism between unreamed nail and bone in a fractured tibia, to identify the mechanical reasons for the unfavorable clinical results, and to identify borderline indications due to biomechanical factors. In a three-dimensional finite element model of a human tibia, horizontal defects were stabilized by means of unreamed nailing for five different fracture locations, including proximal and distal borderline indications for this treatment method. The loading of the bone, the loading of the implant and the inter-fragmentary strains were computed. The findings of this study show that with all muscle and joint contact forces included, nailing leads to considerable unloading of the interlocked bone segments. Unreamed nailing of the distal defect results in an extremely low axial and high shear strain between the fragments. The results suggest that mechanical conditions are advantageous to unreamed nailing of proximal and mid-diaphyseal defects. Apart from biological reasons, clinical problems reported for distal fractures may be due to the less favorable mechanical conditions in unreamed nailing. From a biomechanical perspective, the treatment of distal tibial shaft fractures by means of unreamed nailing without additional fragment contact or without stabilizing the fibula should be carefully reconsidered.

Biomechanical Phenomena↗

Musculo-skeletal loading conditions at the hip during walking and stair climbing.

Musculo-skeletal loading plays an important role in the primary stability of joint replacements and in the biological processes involved in fracture healing. However, current knowledge of musculo-skeletal loading is still limited. In the past, a number of musculo-skeletal models have been developed to estimate loading conditions at the hip. So far, a cycle-to-cycle validation of predicted musculo-skeletal loading by in vivo measurements has not been possible. The aim of this study was to determine the musculo-skeletal loading conditions during walking and climbing stairs for a number of patients and compare these findings to in vivo data. Following total hip arthroplasty, four patients underwent gait analysis during walking and stair climbing. An instrumented femoral prosthesis enabled simultaneous measurement of in vivo hip contact forces. On the basis of CT and X-ray data, individual musculo-skeletal models of the lower extremity were developed for each patient. Muscle and joint contact forces were calculated using an optimization algorithm. The calculated peak hip contact forces both over- and under-estimated the measured forces. They differed by a mean of 12% during walking and 14% during stair climbing. For the first time, a cycle-to-cycle validation of predicted musculo-skeletal loading was possible for walking and climbing stairs in several patients. In all cases, the comparison of in vivo measured and calculated hip contact forces showed good agreement.Thus, the authors consider the presented approach as a useful means to determine valid conditions for the analysis of prosthesis loading, bone modeling or remodeling processes around implants and fracture stability following internal fixation.

Aged↗

Augmentation of a ruptured posterior cruciate ligament provides normal knee joint stability during ligament healing.

OBJECTIVE: To identify an augmentation technique which would provide mechanical protection for the healing posterior cruciate ligament. DESIGN: Six human knee specimens were tested in vitro for posterior knee joint stability after augmenting the cut posterior cruciate ligament by six different techniques using a resorbable double strand Polydioxanone augmentation device. BACKGROUND: A fresh isolated rupture of the posterior cruciate ligament is often treated conservatively. Results have shown that it can heal, but ligament elongations occur frequently. Therefore a method is needed to provide posterior knee joint stability during ligament healing. METHODS: The effect of different femoral augmentation insertions on posterior knee stability was tested by recording the antero-posterior (AP) position of the tibia and the augmentation force. Testing was performed during flexion--extension cycles and under posterior shear loads. RESULTS: The insertion combination that proved to stabilize the joints best consisted of one augmentation strand leading along the antero-lateral posterior cruciate ligament fibres and inserting at the distal end of the Blumensaat line and one strand leading along the posteriormedial fibres and inserting in the middle of the Blumensaat line. AP translations similar to those occurring in healthy knee joints could be achieved. CONCLUSIONS: It is possible to restore normal posterior knee joint stability by implanting a double strand augmentation device. This can help a posterior cruciate ligament to heal under non-elongated conditions.

Absorbable Implants↗

Prediction of strength of cortical bone in vitro by microcomputed tomography.

OBJECTIVE: The aim of this study was to evaluate the predictive value of bone mineral density and intracortical porosity measured by microcomputed tomography for the strength of cortical bone biopsies. DESIGN: Experimental study comparing the predictive value of bone mineral density and of intracortical porosity determined in vitro by microcomputed tomography for the mechanical properties of cortical bone cylinders. BACKGROUND: The assessment of cortical bone strength might be relevant for the prediction of fracture risk or the choice of suitable therapy strategies in orthopaedic surgery. The predictive value of cortical density for the mechanical properties is discussed controversially. The relevance of intracortical porosity measured by histomorphometry has been established, but the predictive value of porosity determined by microcomputed tomography remains to be explored. METHODS: Femoral cortical bone specimens from the mid diaphysis of 24 patients were harvested during total hip replacement procedure at the location, where a diaphyseal hole (diameter 4.5 mm) was drilled in order to reduce the intramedullary pressure. In vitro intracortical porosity and bone mineral density measurements by microcomputed tomography were compared with strength and elastic modulus assessed by a compression test transverse to the Haversian systems of the same specimens. RESULTS: Significant negative correlations were found between porosity measured by microcomputed tomography scans and yield stress, stiffness and elastic modulus (P<0.001), however, the positive correlations between bone mineral density and mechanical parameters were stronger (P<0.0001). The mechanical parameter best predicted by mineral density as well as by porosity was yield stress (r=0.72,P<0.0001;r=-0.64,P<0.001). CONCLUSIONS: Bone mineral density determined by microcomputed tomography imaging in vitro may be a potent method to predict mechanical properties of cortical bone non-destructively. The application in vivo remains to be explored.

Aged↗

Predictive value of Singh index and bone mineral density measured by quantitative computed tomography in determining the local cancellous bone quality of the proximal femur.

OBJECTIVE: The purpose of this study was to assess the predictive value of the Singh index as well as quantitative computed tomography for the in vitro local mechanical competence of the cancellous bone of the proximal femur. DESIGN: An experimental study examining the relation between mechanical properties and bone mineral density of the femoral neck determined in vitro and the clinical estimated Singh index on X-rays. BACKGROUND: Evaluation of the predictive value of the Singh index, an inexpensive and simple technique for the mechanical properties of the cancellous bone of the proximal femur. METHODS: The bone quality of the proximal femur of 34 patients undergoing total hip replacement was estimated by roentgenography using the Singh index. Bone mineral density was quantified by quantitative computed tomography using cylindrical cancellous bone biopsies harvested during the total hip replacement procedure by a new biopsy method. The mechanical properties of the bone specimens (Young's modulus, strength and maximum energy absorption E(max)) were measured by mechanical testing of the bone biopsies. RESULTS: A strong correlation of the Singh index versus material properties of cancellous bone was noted (r=0.66 for Young's modulus, r=0.73 for strength and r=0.69 for E(max), P<0.0001). The correlations of bone mineral density measured by quantitative computed tomography versus Young's modulus, strength and energy absorption E(max) were significant. Strength was predicted best (r=0.82; P<0.0001), followed by E(max) (r=0.79; P<0.0001) and Young's Modulus (r=0.73; P<0.0001). CONCLUSIONS: We conclude, that assessment of bone mineral density by quantitative computed tomography is a reliable and precise method for the estimation of cancellous bone material properties. The Singh index provides a rough estimate for the mechanical competence of the proximal femur. It is inexpensive, simply to assess and can in some cases replace the measurement of bone mineral density, notably in cases of marked decrease in bone density.

Aged↗

Intradiscal pressure together with anthropometric data--a data set for the validation of models.

OBJECTIVE: To provide a database of intradiscal pressure measurements together with anthropometric data as basis for the validation of models that predict spinal loads. DESIGN: Intradiscal pressure was measured in a non-degenerated L4-5 disc of a volunteer. The anthropometric characteristics of this subject were extensively determined. BACKGROUND: Since it is usually impossible to quantify the load in the spine directly, it is predicted by various biomechanical models. However, they often cannot be validated because of the few in vivo data and missing anthropometric characteristics pertaining to them. METHODS: A pressure transducer (diameter 1.5 mm) was implanted in the nucleus pulposus of a non-degenerated L4-5 disc of a volunteer. Pressure was determined during exercises while standing, lifting activities, sitting unsupported on a stool or an ergonomic sitting ball, sitting in different postures and others. The anthropometric characteristics were determined using different tools. RESULTS: Pressure values: relaxed standing 0.5 MPa; standing flexed forward 1.1 MPa; standing extended backward 0.6 MPa; sitting unsupported 0.46 MPa; maximum values during lateral bending 0.6 MPa, during axial rotation 0.7 MPa, lifting a 20 kg weight with a round flexed back 2.3 MPa, with flexed knees 1.7 MPa, close to the body 1.1 MPa; sitting unsupported relaxed 0.45 MPa, actively straightening the back 0.55 MPa, with flexion 0.9 MPa; non-chalant sitting 0.3 MPa and others. Anthropometric characteristics with emphasis on data for the trunk are provided in tables.Conclusions. Intradiscal pressure depends on the kind of preceding activity, posture, external loads and muscle activity. RELEVANCE: The data set can be used to verify a biomechanical model adjusted to the individual characteristics by a comparison of measured and predicted intradiscal pressures.

Anthropometry↗

Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients.

OBJECTIVE: The aim of this study was to determine the loading of the proximal femur during daily activities and to quantify the influence of femoral anteversion. DESIGN: This study combined experimental and analytical approaches to determine the in vivo loading at the hip joint. A numerical musculo-skeletal model was validated against measured in vivo hip contact forces and then used to analyse the influence of anteversion on the loading conditions in the femur. BACKGROUND: Musculo-skeletal loading of long bones is essential for joint replacement and fracture healing. Although joint contact forces have previously been measured in selected patients, the interaction between femoral anteversion and the associated musculo-skeletal loading environment remains unknown. METHODS: The gait of four patients with force measuring hip prostheses was analysed during walking and stair-climbing. Musculo-skeletal loading was determined using individual numerical models by minimising the sum of the muscle forces. RESULTS: Experimentally and numerically determined hip contact forces agreed both qualitatively and quantitatively. Muscle activity resulted in compression of the femur and small shear forces in the meta- and epi-physeal regions. Increasing the anteversion to an angle of 30 degrees increased hip contact forces and bending moments up to 28%. CONCLUSIONS: This study has shown that femoral anteversion has a strong influence on the musculo-skeletal loading environment in the proximal femur. RELEVANCE: Detailed musculo-skeletal modelling may allow pre-surgical, patient specific optimisation of loading on implant, bone and soft tissues.

Biomechanical Phenomena↗

Cell alignment is induced by cyclic changes in cell length: studies of cells grown in cyclically stretched substrates.

Many types of cells, when grown on the surface of a cyclically stretched substrate, align away from the stretch direction. Although cell alignment has been described as an avoidance response to stretch, the specific deformation signal that causes a cell population to become aligned has not been identified. Planar surface deformation is characterized by three strains: two normal strains describe the length changes of two initially perpendicular lines and one shear strain describes the change in the angle between the two lines. The present study was designed to determine which, if any, of the three strains was the signal for cell alignment. Human fibroblasts and osteoblasts were grown in deformable, rectangular, silicone culture dishes coated with ProNectin, a biosynthetic polymer containing the RGD ligand of fibronectin. 24 h after plating the cells, the dishes were cyclically stretched at 1 Hz to peak dish stretches of 0% (control), 4%, 8%, and 12%. After 24 h of stretching, the cells were fixed, stained, and their orientations measured. The cell orientation distribution was determined by calculating the percent of cells whose orientation was within each of eighteen 5 degrees angular intervals. We found that the alignment response was primarily driven by the substrate strain which tended to lengthen the cell (axial strain). We also found that for each cell type there was an axial strain limit above which few cells were found. The axial strain limit for fibroblasts, 4.2 +/- 0.4%, (mean +/- 95% confidence), was lower than for osteoblasts, 6.4 +/- 0.6%. We suggest that the fibroblasts are more responsive to stretch because of their more highly developed actin cytoskeleton.

Adolescent↗

Self-injurious behaviors in eating-disordered patients.

High rates of self-injurious behaviors (SIBs) have been described in eating-disordered patients. The present study in 134 female inpatients suffering from an eating disorder (ED) confirmed this: 44% of the total group reported at least one form of SIB (mostly hair pulling, scratching, cutting, or bruising) with a mean age at onset of 17.5 years. No major differences have been found between the subgroups (anorexics, bulimics). The considerable number of patients who did not feel any pain during SIB showed more tendency towards dissociative experiences. Those who admitted SIB reported higher levels of psychological dysfunctioning, dissociative experiences, and impulsiveness.

Journal Article↗

Mechanical stimulation by external application of cyclic tensile strains does not effectively enhance bone healing.

OBJECTIVE: To determine whether an externally induced interfragmentary movement enhances the healing process of a fracture under flexible fixation. DESIGN: Randomized, prospective in vivo animal study with control group. Twenty-four skeletally mature Merino sheep were randomly assigned to six groups of four animals, which received cyclic interfragmentary movements of 0.2 and 0.8 millimeters and stimulation frequencies of 1, 5, and 10 Hertz, respectively. Twelve animals did not receive any externally applied stimulation and served as a control group. SETTING: Unrestricted stall activity with weight bearing reduced by tenotomy of the Achilles tendon. INTERVENTIONS: Osteotomy of the tibial diaphysis with three-millimeter gap width fixed with a six-pin, monolateral, double-bar external fixator. Interfragmentary movement of the osteotomy gap was externally induced by a motor-driven actuator unit. Five hundred cycles inducing nonuniform tensile strains within the gap were performed each day. MAIN OUTCOME MEASUREMENTS: Nine weeks after surgery, the animals were killed, and bone mineral density and callus cross-sectional area were measured with quantitative computed tomography. Callus projectional area was assessed by radiographs, and mechanical stability was determined with a three-point bending test. RESULTS: External stimulation with nonuniform cyclic tensile strains did slightly affect but not significantly enhance the fracture healing process. Varying the stimulation frequency had no influence on the healing process. The stimulation with 0.8 millimeter displacement magnitude resulted in a larger periosteal callus, but a decreased bone mineral density compared with the 0.2-millimeter displacement magnitude. The stimulation had no significant influence on the mechanical properties of the healing bone. CONCLUSIONS: Induced cyclic tensile strains did not produce a relevant enhancement of bone healing under flexible fixation.

Animals↗

Radiographic results of callus distraction aided by pulsed low-intensity ultrasound.

OBJECTIVES: To determine whether pulsed low-intensity ultrasound (frequency of 1.5 megahertz, pulsed by one kilohertz, signal burst width of 200 microseconds, intensity of thirty milliwatts per square centimeter, and daily treatment time of twenty minutes per day) stimulates regenerate maturation after callus distraction. DESIGN: Prospective, controlled animal trial. METHODS: Operatively, we created a fifteen-millimeter defect in the right metatarsus of eighteen female mature merino sheep. A segmental transport was begun on Day 5 using a high-stiffness experimental ring fixator. The distraction rate was one millimeter per day divided into two increments of 0.5 millimeters each. On Day 21 after the operation, distraction was finished and the maturation period started and lasted until Day 84 after operation. During this period, Group 1 was treated with a daily twenty-minute low-intensity ultrasound stimulation (frequency of 1.5 megahertz, pulsed by one kilohertz, signal burst width of 200 microseconds, intensity of thirty milliwatts per square centimeter). Group 2 had no stimulation. Animals bore full weight. Plain radiographs in the anteroposterior view were taken every two weeks during the maturation period. After the animals were killed on Day 84, anteroposterior and lateral high resolution radiographs and computed tomography (CT) scans of the regenerate were performed. For each plain and high resolution radiograph, two different relationships (callus relation, the ratio of the amount of periosteal callus to the size of the space between the proximal fragment and transported segment; and interzone relation, the ratio of the fibrous callus interzone to the size of the new formed callus) were calculated. Using CT scan, callus area, bone density, and bone mineral content were evaluated. RESULTS: The results of interzone relation (both views) and callus relation (lateral view) in high-resolution radiographs and bone mineral content in CT indicate a significantly accelerated maturation of the regenerate in the ultrasound stimulated group even when a Bonferroni-Holm adjustment was used for multiple testing. CONCLUSION: Pulsed low-intensity ultrasound appears to stimulate the healing processes in the regenerate in this animal model and may have applicability in clinical practice.

Animals↗

Effects of neck movements on stability and subsidence in cervical interbody fusion: an in vitro study.

OBJECT: The aim of this in vitro study was to determine the influence of simulated postoperative neck movements on the stabilizing effect and subsidence of four different anterior cervical interbody fusion devices. Emphasis was placed on the relation between subsidence and spinal stability. METHODS: The flexibility of 24 human cervical spine specimens was tested before and directly after being stabilized with a WING, BAK/C, AcroMed I/F cage, or with bone cement in standard flexibility tests under 50 N axial preload. Thereafter, 700 pure moment loading cycles (+/- 2 Nm) were applied in randomized directions to simulate physiological neck movements. Additional flexibility tests in combination with measurements of the subsidence depth were conducted after 50, 100, 200, 300, 500, and 700 loading cycles. In all four groups, simulated postoperative neck movements caused an increase of the range of motion (ROM) ranging from 0.4 to 3.1 degrees and of the neutral zone from 0.1 to 4.2 degrees. This increase in flexibility was most distinct in extension followed by flexion, lateral bending, and axial rotation. After cyclic loading, ROM tended to be lower in the group fitted with AcroMed cages (3.3 degrees in right lateral bending, 3.5 degrees in left axial rotation, 7.8 degrees in flexion, 8.3 degrees in extension) and in the group in which bone cement was applied (5.4 degrees, 2.5 degrees, 7.4 degrees, and 8.8 degrees, respectively) than in those fixed with the WING (6.3 degrees, 5.4 degrees, 9.7 degrees, and 6.9 degrees, respectively) and BAK cages (6.2 degrees, 4.5 degrees, 10.2 degrees, and 11.6 degrees, respectively). CONCLUSIONS: Simulated repeated neck movements not only caused an increase of the flexibility but also subsidence of the implants into the adjacent vertebrae. The relation between flexibility increase and subsidence seemed to depend on the implant design: subsiding BAK/C cages partially supported stability whereas subsiding WING cages and AcroMed cages did not.

Biomechanical Phenomena↗

Subsidence resulting from simulated postoperative neck movements: an in vitro investigation with a new cervical fusion cage.

STUDY DESIGN: A biomechanical in vitro subsidence test of different cervical interbody fusion devices was performed using a new testing protocol that simulates physiologic conditions. OBJECTIVES: To investigate the effect of simulated postoperative neck movements on the subsidence of the new WING cervical interbody fusion cage in comparison with two other cages and bone cement. SUMMARY OF BACKGROUND DATA: Cervical interbody fusion cages sometimes cause complications because of subsidence into the adjacent vertebrae with collapse of the intervertebral space. Complications such as cage dislocation or nonunion with instability also have been reported. To prevent such complications, the new WING cervical interbody fusion cage (Medinorm AG, Quierschied, Germany) has been developed. Its area of contact with the adjacent vertebrae is supposed to be large enough to resist excessive subsidence and small enough to prevent stress protection of the tissue growing in the cage. METHODS: In this study, 24 human cervical spine specimens were tested after stabilization with either a WING, BAK/C, AcroMed I/F cage or bone cement. Then, in a new testing protocol, 700 pure-moment loading cycles (+/-2 Nm) were applied in randomized directions (lateral bending, flexion-extension, and axial rotation alone or in combination with each other) to simulate the patient's neck movements during the first few postoperative days. Measurements of the subsidence depth (total height loss) in combination with flexibility tests (+/-2.5 Nm) were performed before cyclic loading and after 50, 100, 200, 300, 500, and 700 loading cycles. RESULTS: Cyclic loading caused subsidence in all four device groups, most distinct with BAK/C-cages (1.63 mm after 700 loading cycles) followed by the new WING (0.90 mm) and the AcroMed (0.82 mm) cages. No statistically significant difference could be found among the three cage designs. However, all three cage types showed a significantly higher subsidence depth than bone cement (0.48 mm;P = 0.023 between each of the three cage-types and bone cement). A moderate correlation between bone mineral density and subsidence depth could be found only in the BAK/C group (r2 = 0.495). A large subsidence depth after 700 loading cycles was associated with a large flexibility increase in the WING (r2 = 0.786) and AcroMed groups (r2 = 0.21), but with a small flexibility increase in the BAK/C group (r2 = 0.58). CONCLUSIONS: Postoperative neck movements caused subsidence in all cervical interbody implant types. The new WING cage and the AcroMed cage seemed to have a better resistance against subsidence than the BAK/C cage. However, all three cage types had a significantly higher subsidence tendency than bone cement.

Bone Cements↗

Effects of specimen length on the monosegmental motion behavior of the lumbar spine.

STUDY DESIGN: An in vitro biomechanical analysis of the segmental motion behavior of the same segments in polysegmental (five segments), bisegmental, and monosegmental specimens using sheep lumbosacral spines. OBJECTIVES: To investigate the effect of specimen length on monosegmental motion behavior. These data may be helpful in planning in vitro tests and in comparing results of studies using specimens of different lengths. SUMMARY OF BACKGROUND DATA: The length of spinal specimens used for in vitro stability tests varies greatly, depending on the purpose of the study. Some investigators prefer testing specimens with one adjacent segment on either end of the region of interest. Others favor specimens as short as possible. METHODS: In a first step, seven sheep spine specimens, L3-S1 (note that sheep spines normally have seven lumbar vertebrae), each were tested without preload in a spine-loading apparatus. Alternating sequences of pure lateral bending, flexion/extension, and axial rotation moments (+/-3.75 Nm) were applied continuously. The motion in each single segment was measured simultaneously. Then, these polysegmental specimens were cut into two bisegmental specimens, L3-L5 and L6-S1, and tested in the same way. Finally, another vertebra was removed to obtain two monosegmental specimens, L3-L4 and L7-S1, and to test them as described. RESULTS: In general, the range of motion at L3-L4 and L7-S1 was smaller when tested in polysegmental than in monosegmental specimens. In polysegmental specimens (five segments), the range of motion at L3-L4 and L7-S1 was approximately 80% (range, 70.6-92.5%) and in bisegmental specimens approximately 95% (range, 66.7-100%) of their range of motion measured in monosegmental specimens. Neutral zone and coupled motions showed the inverse behavior. Significant differences were found. However, they were not consistent with either the loading direction or with the specimen length. CONCLUSIONS: For comparison of results, the specimen length should be kept constant within one experiment. Segmental motion behavior of specimens with different lengths should be compared only qualitatively.

Animals↗

[Mechanical modification of callus healing].

Interfragmentary movement and size of the fracture gap influence fracture healing. Limited movements promote callus formation and may result in increased mechanical stability. Although larger movements still promote callus formation, the bony consolidation of the fracture is hampered. Fracture healing is also hampered if the size of the fracture gap is too large. A combination of large movement and large gap bears the risk of non-union. Therefore, having in mind a minimally invasive surgical approach, one should strive for good reduction of the fracture ends and flexible yet stable osteosynthesis. Dynamization of the fracture by enabling axial movement will close the fracture gap, stimulate tissue differentiation and possibly accelerate the healing process. External mechanical stimulation, however, has not been shown to effectively enhance the healing process under flexible fixation or in load-bearing patients.

Animals↗