[In vitro cell behavior of human osteoblasts after physiological dynamic stretching].

The cell activity of human bone derived cell cultures was studied after mechanical stimulation by cyclic strain at a magnitude occurring in physiologically loaded bone tissue. Monolayers of subconfluently grown human bone derived cells were stretched in rectangular silicone dishes with cyclic uniaxial movement along their longitudinal axes. Strain was applied over two days for 30 min per day with a frequency of 1 Hz and a strain magnitude of 1000 mustrain. Cyclic stretching of the cells resulted in an increased proliferation (10-48%) and carboxyterminal collagen type I propeptide release (7-49%) of human cancellous bone derived osteoblasts while alkaline phosphatase activity and osteocalcin release were significantly reduced by 9-25% and 5-32% respectively. These results demonstrate that cyclic strain at physiologic magnitude leads to an increase of osteoblast activities related to matrix production while those activities which are characteristic for the differentiated osteoblast and relevant for matrix mineralization are decreased.

Adult↗

Vertebral body replacement with a bioglass-polyurethane composite in spine metastases--clinical, radiological and biomechanical results.

Metastatic spine lesions frequently require corpectomy in order to achieve decompression of the spinal cord and restoration of spinal stability. A variety of systems have been developed for vertebral body replacement. In patients with prolonged life expectancy due to an improvement of both systemic and local therapy, treatment results can be impaired by a loosening at the implant-bone interface or mechanical failure. Furthermore, early detection of a metastatic recurrence using sensitive imaging modalities like computed tomography (CT) and magnetic resonance imaging (MRI) is possible in these patients without artefact interference. The aim of our pilot study was to evaluate the clinical applicability and results of a new radiolucent system for vertebral body replacement in the lumbar spine. The system consists of bone-integrating biocompatible materials - a polyetherurethane/bioglass composite (PU-C) replacement body and an integrated plate of carbon-fibre reinforced polyetheretherketone (CF-PEEK) - and provides high primary stability with anterior instrumentation alone. In a current prospective study, five patients with metastatic lesions of the lumbar spine were treated by corpectomy and reconstruction using this new system. Good primary stability was achieved in all cases. Follow-up (median 15 months) using CT and MRI revealed progressive osseous integration of the PU-C spacer in four patients surviving more than 6 months. Results obtained from imaging methods were confirmed following autopsy by biomechanical investigation of an explanted device. From these data, it can be concluded that implantation of the new radiolucent system provides sufficient long-term stability for the requirements of selected tumour patients with improved prognosis.

Adult↗

Primary stabilizing effect of interbody fusion devices for the cervical spine: an in vitro comparison between three different cage types and bone cement.

Interbody fusion cages are small hollow implants that are inserted into the intervertebral space to restore physiological disc height and to allow bony fusion. They sometimes cause clinical complications due to instability, subsidence or dislocation. These are basic biomechanical parameters, which influence strongly the quality of a fusion device; however, only few data about these parameters are available. Therefore, the purpose of the present study was to investigate the primary stabilizing effect of four different cervical fusion devices in in vitro flexibility tests. Twenty-four human cervical spine segments were used in this study. After anterior discectomy, fusion was performed either with a WING cage (Medinorm AG, Germany), a BAK/C cage (Sulzer SpineTech, USA), an AcroMed cervical I/F cage (DePuy AcroMed International, UK) or bone cement (Sulzer, Switzerland). All specimens were tested in a spine tester in the intact condition and after implantation of one of the four devices. Alternating sequences of pure lateral bending, flexion-extension and axial rotation moments (+/- 2.5 Nm) were applied continuously and the motions in each segment were measured simultaneously. In general, all tested implants had a stabilizing effect. This was most obvious in lateral bending, where the range of motion was between 0.29 (AcroMed cage) and 0.62 (BAK/C cage) with respect to the intact specimen (= 1.00). In lateral bending, flexion and axial rotation, the AcroMed cervical I/F cages had the highest stabilizing effect, followed by bone cement, WING cages and BAK/C cages. In extension, specimens fused with bone cement were most stable. With respect to the primary stabilizing effect, cages, especially the AcroMed I/F cage but also the WING cage and to a minor extent the BAK/C cage, seem to be a good alternative to bone cement in cervical interbody fusion. Other characteristics, such as the effect of implant design on subsidence tendency and the promotion of bone ingrowth, have to be determined in further studies.

Biomechanical Phenomena↗

Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in-vitro comparison with two established implant systems.

Posterior instrumentation of the occipito-cervical spine has become an established procedure in a variety of indications. The use of rod-screw systems improved posterior instrumentation as it allows optimal screw positioning adapted to the individual anatomic situation. However, there are still some drawbacks concerning the different implant designs. Therefore, a new modular rod-screw implant system has been developed to overcome some of the drawbacks of established systems. The aim of this study was to evaluate whether posterior internal fixation of the occipito-cervical spine with the new implant system improves primary biomechanical stability. Three different internal fixation systems were compared in this study: the CerviFix System, the Olerud Cervical Rod Spinal System and the newly developed Neon Occipito Cervical System. Eight human cervical spine CO/C5 specimens were instrumented from C0 to C4 with occipital fixation, transarticular screws in C1/C2 and lateral mass or pedicle screws in C3 and C4. The specimens were tested in flexion/extension, axial rotation, and lateral bending using pure moments of +/- 2.5 Nm without axial preload. After testing the intact spine, the different instrumentations were tested after destabilising C0/C2 and C3/C4. Primary stability was significantly increased, in all load cases, with the new modular implant system compared to the other implant systems. Pedicle screw instrumentation tended to be more stable compared to lateral mass screws; nevertheless, significant differences were observed only for lateral bending. As the experimental design precluded any cyclic testing, the data represent only the primary stability of the implants. In summary, this study showed that posterior instrumentation of the cervical spine using the new Neon Occipito Cervical System improves primary biomechanical stability compared to the CerviFix System and the Olerud Cervical Rod Spinal System.

Biomechanical Phenomena↗

Load-displacement properties of the normal and injured lower cervical spine in vitro.

The objective of this study was to determine which discoligamentous structures of the lower cervical spine provide significant stability with regard to different loading conditions. Accordingly, the load-displacement properties of the normal and injured lower cervical spine were tested in vitro. Four artificially created stages of increasing discoligamentous instability of the segment C5/6 were compared to the normal C5/6 segment. Six fresh human cadaver spine segments C4-C7 were tested in flexion/extension, axial rotation, and lateral bending using pure moments of +/- 2.5 Nm without axial preload. Five conditions were investigated consecutively: (1) the intact functional spinal unit (FSU) C5/6; (2) the FSU C5/6 with the anterior longitudinal ligament and the intertransverse ligaments sectioned; (3) the FSU C5/6 with an additional 10-mm-deep incision of the anterior half of the anulus fibrosus and the disc; (4) the FSU C5/6 with additionally sectioned ligamenta flava as well as interspinous and supraspinous ligaments; (5) the FSU C5/6 with additional capsulotomy of the facet joints. In flexion/extension, significant differences were observed concerning range of motion (ROM) and neutral zone (NZ) for all four stages of instability compared to the intact FSU. In axial rotation, only the stage 4 instability showed a significantly increased ROM and NZ compared to the intact FSU. For lateral bending, no significant differences were observed. Based on these data, we conclude that flexion/extension is the most sensitive load-direction for the tested discoligamentous instabilities.

Aged↗

Dynamic cell stretching increases human osteoblast proliferation and CICP synthesis but decreases osteocalcin synthesis and alkaline phosphatase activity.

The cell activity of human-bone-derived cell cultures was studied after mechanical stimulation by cyclic strain at a magnitude occurring in physiologically loaded bone tissue. Monolayers of subconfluently grown human-bone-derived cells were stretched in rectangular silicone dishes with cyclic predominantly uniaxial movement along their longitudinal axes. Strain was applied over two days for 30 min per day with a frequency of 1 Hz and a strain magnitude of 1000 microstrain. Cyclic stretching of the cells resulted in an increased proliferation (10-48%) and carboxyterminal collagen type I propeptide release (7-49%) of human-cancellous bone-derived osteoblasts while alkaline phosphatase activity and osteocalcin release were significantly reduced by 9-25 and 5-32%, respectively. These results demonstrate that cyclic strain at physiologic magnitude leads to an increase of osteoblast activities related to matrix production while those activities which are characteristic for the differentiated osteoblast and relevant for matrix mineralization are decreased.

Alkaline Phosphatase↗

Initial stability of fully and partially cemented femoral stems.

OBJECTIVE: To test the initial stability of a newly designed partially cemented femoral stem in comparison with a fully cemented conventional stem. DESIGN: An in vitro study to determine the interface motion between femoral stem and bone as a response to loading. BACKGROUND: The aim of the new prosthesis design is a proximal load transfer by a defined partial cement fixation in the proximal femur region and a slim prosthesis stem in the distal region. Before a clinical study can be started, the new stem has to show an initial stability comparable to that of fully cemented prostheses. METHOD: Six paired fresh cadaveric femora were used for the testing of the new partially cemented stem (Option 3000, Mathys Orthopaedics, Bettlach, Switzerland) and a fully cemented stem (Weber Shaft, AlloPro, Baar, Swizerland). Under cyclic loading up to 1600 N hip joint forces, the interface motion between implants and bone was measured at six locations. RESULTS: Both stems showed uncritical interface motions below 43 microm. However, the Option 3000 stem exhibited significantly smaller motions in the proximal region and slightly larger movements in the distal regions than the Weber prosthesis. CONCLUSIONS: The new type of partially cemented stem provided a comparable initial stability to the fully cemented Weber prosthesis. Relevance The high initial stability of the Option 3000 stem justified the clinical use of the new implant. More than 100 implantations in the last three years, with very good preliminary clinical results, support the preclinical findings.

Aged↗

Comparative stability of the "Internal Fixator" and the "Universal Spine System" and the effect of crosslinking transfixating systems. A biomechanical in vitro study.

In this study, the three-dimensional stabilizing capabilities of the AO-Internal Fixator (IF) and the new Universal Spine System (USS) were investigated. Both devices were tested without and with the cross-link system (IF, IFC, USS, USSC). To determine biomechanical characteristics, a human thoracolumbar spine instability model with resection of the vertebral body Th12 was created. The vertebral body was replaced by a spacer and transpedicular posterior stabilization was performed from Th11 to L1. All devices reduced the range of motion (ROM) significantly compared to the values of the intact specimen. In flexion the IFC showed the highest reduction of ROM (85% of intact), followed by the USSC, USS and IF (79% of intact). In extension the ROM was restored again most by the IFC (52% of intact), followed by the USSC, IF and USS (44% of intact). In lateral bending stability was provided by the USSC (right 78% and left 81% of intact), followed in right lateral bending by the IF, IFC and USS and in left lateral bending by the USS, IF and IFC. In axial rotation the ROM was reduced primary by the IFC (right 51% and left 46% of intact), followed in right axial rotation by the USS, USSC and IF, in left axial rotation by the USSC, USS and IF. Additional stability by crosslinking has been provided in the IF and the USS in flexion and extension, in the USS in lateral bending and in the IF in axial rotation nonsignificantly. The neutral zone (NZ) was reduced by posterior instrumentation in flexion/extension and right/left lateral bending significantly. In axial rotation only the USSC decreased the NZ below intact levels. The study showed no statistical significant differences in the stabilizing capabilities of the USS compared to the IF. For both implants the cross-link system increased stability in the chosen instability model insignificantly only.

Aged↗

Stabilizing effect of posterior lumbar interbody fusion cages before and after cyclic loading.

OBJECT: The function of interbody fusion cages is to stabilize spinal segments primarily by distracting them as well as by allowing bone ingrowth and fusion. An important condition for efficient formation of bone tissue is achieving adequate spinal stability. However, the initial stability may be reduced due to repeated movements of the spine during everyday activity. Therefore, in addition to immediate stability, stability after cyclic loading is of remarkable relevance; however, this has not yet been investigated. The object of this study was to investigate the immediate stabilizing effect of three different posterior lumbar interbody fusion cages and to clarify the effect of cyclic loading on the stabilization. METHODS: Before and directly after implantation of a Zientek, Stryker, or Ray posterior lumbar interbody fusion cage, 24 lumbar spine segment specimens were each evaluated in a spine tester. Pure lateral bending, flexion-extension, and axial rotation moments (+/- 7.5 Nm) were applied continuously. The motion in each specimen was measured simultaneously. The specimens were then loaded cyclically (40,000 cycles, 5 Hz) with an axial compression force ranging from 200 to 1000 N. Finally, they were tested once again in the spine tester. CONCLUSIONS: In general, a decrease of movement in all loading directions was noted after insertion of the Zientek and Ray cages and an increase of movement after implantation of a Stryker cage. In all three cage groups greater stability was demonstrated in lateral bending and flexion than in extension and axial rotation. Reduced stability during cyclic loading was observed in all three cage groups; however, loss of stability was most pronounced when the Ray cage was used.

Exercise Test↗

The influence of stiffness of the fixator on maturation of callus after segmental transport.

The treatment of large bony defects by callus distraction is well accepted, but the duration of treatment is long and the rate of complications increases accordingly. We have examined the effect of the stiffness of the axial fixator on reducing the time for maturation of callus. We created a mid-diaphyseal defect of 15 mm in the metatarsal bone in sheep and stabilised it with a ring fixator. After four days a bony segment was transported for 16 days at 1 mm per day. After 64 days the animals were divided into four groups, three with axial interfragmentary movement (IFM) of 0.5, 1.2 and 3.0 mm, respectively, and a control group. The 3.0 mm IFM group had the smallest bone density (p = 0.001) and area of callus and the largest IFM after 12 weeks; it also had typical clinical signs of hypertrophic nonunion. The most rapid stiffening of the callus was in the 0.5 mm group which had the smallest IFM (p = 0.04) after 12 weeks and radiological signs of bridging of the defect. These results indicate that suitable dynamic axial stimulation can enhance maturation of distraction callus when the initial amplitude is small, but that a large IFM can lead to delayed union.

Animals↗

In vitro effects of dynamic strain on the proliferative and metabolic activity of human osteoblasts.

AIM OF THE STUDY: It has been well shown by human and animal studies that mechanical load is an important regulator of skeletal mass and architecture. However, cellular reactions which adapt bone tissue to the mechanical environment are not definitively determined. For this purpose we studied the cell activity of human bone derived cell cultures after mechanical stimulation by cyclic, uniaxial strain at a magnitude occurring in normal loaded bone tissue. MATERIALS AND METHODS: Human osteoblasts were isolated from cancellous bone biopsies of 5 different donors. Cell seeding was made in DMEM in a density of 10.000 cells/cm(2) on deformable culture dishes for three days prior to initiating cell stretching at 1000 microstrain, 1Hz for 1800 cycles for two subsequent days with an especially developed cell stretching device. 48h after the second stimulation cells were harvested and cell number was determined with a Coulter Counter. Cell bound alkaline phosphatase activity was analyzed in cell lysates by a colorimetric assay, osteocalcin and CICP (procollagen I propeptide) production were analyzed in cell supernatants with ELISAs. Three parallel cultures were tested. STATISTICS: Wilcoxon. RESULTS: In all experiments mechanical stimulation resulted in a significant increase in cell number (10-48%) and CICP release (7-49%). Simultaneously a significant decrease in alkaline phosphatase activity (9-25%) and osteocalcin release (5-32%) could be observed. CONCLUSIONS: The results demonstrate that cyclic strain at physiologic magnitude leads to an increase of early osteoblast activities related to matrix production while those activities which are characteristic for the differentiated osteoblast and relevant for matrix mineralization are decreased. These new findings confirm in vivo observations about the importance of dynamic strain for bone formation during fracture healing and bone remodeling and could contribute to the optimization of fracture healing.

Journal Article↗

Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine. In vitro comparison with two established internal fixation systems.

STUDY DESIGN: The primary biomechanical stability of anterior internal fixation of the cervical spine obtained with a new monocortical expansion screw in vitro was evaluated. OBJECTIVES: To determine whether the anterior internal fixation of the spine obtained with the new monocortical expansion screw provides biomechanical stability comparable with that obtained with bicortical fixation. SUMMARY OF BACKGROUND DATA: The anterior plate instrumentation used with bicortical screw fixation in the cervical spine provides a primary stability superior to that associated with monocortical screw fixation. However, bicortical screws have the potential to perforate the posterior cortex. Therefore, monocortical instrumentation systems were developed, but without the biomechanical stability associated with bicortical systems. A new expansion screw for monocortical fixation was developed to improve biomechanical stability of monocortical systems. METHODS: Three different internal fixation systems were compared in this study: 1) H-plate with AO 3.5-mm bicortical screws, 2) cervical spine locking plate with monocortical screws, and 3) H-plate with the new monocortical expansion screws. Eight fresh human cadaver spine segments from C4 to C7 were tested in flexion-extension, axial rotation, and lateral bending using pure moments of +/- 2.5 Nm without axial preload. Five conditions were investigated consecutively: 1) intact spine; 2) uninstrumented spine with the segment C5-C6 destabilized; 3-5) instrumentation of the segment C5-C6 with the three implants mentioned above after removal of the disc and insertion of an interbody spacer. RESULTS: Between bicortical and monocortical expansion screw H-plate fixation, no significant differences were observed in all load cases concerning range of motion and neutral zone. The neutral zone and range of motion were significantly larger for the cervical spine locking plate than for bicortical and monocortical expansion screw fixation in all load cases, except neutral zone for axial rotation versus bicortical screw fixation. The instrumented cases only had a significantly lower range of motion and neutral zone than the intact cases in extension-flexion, whereas for lateral bending and axial rotation no significant differences could be observed. Because the experimental design precluded any cyclic testing, the data represent only the primary stability of the implants. CONCLUSIONS: In anterior instrumentation of the cervical spine using a H-plate, the new monocortical expansion screw provides the same biomechanical stability as the bicortical 3.5-mm AO screw and a significantly better biomechanical stability than the cervical spine locking plate. Therefore, the expansion screw may be an alternative to the bicortical fixation and does not involve the risk of penetration of the posterior vertebral body cortex.

Aged↗

A new radiolucent system for vertebral body replacement: its stability in comparison to other systems.

Anterior intervention of metastatic lesions of the spine can accomplish relief of pain, spinal decompression, and restoration of spinal stability. Ventral vertebral body replacements have been developed to provide these conditions but there have been problems with loosening at the implant-bone interface, mechanical failure, and X-ray artifacts from the metal. Intraoperative stability of the vertebral body replacement is especially critical to avoid loosening of the implant and to achieve long-term bony incorporation. This study compared the biomechanical performance in vitro of a new radiolucent system for vertebral body replacement to three currently marketed systems. The new system features a composite bioglass-polyurethane body and a new configuration of polymeric fastening hardware. Range of motion, neutral zone, and several interfacial motion parameters were measured under pure moments of 3.75 Nm in the three anatomical directions. The new system provided the significantly highest restraint of motion for all parameters. Mechanically, the new system is preferable at least initially to a sampling of systems representative of those currently used.

Artifacts↗

Cell orientation induced by extracellular signals.

Cells like fibroblasts and osteoblasts are oriented by different extracellular guiding signals like an electric field, a bent surface, and a periodically stretched surface. An automatic controller is responsible for the cell alignment. The controller contains both a deterministic and a stochastic signal. The following machine properties were determined: (1) The angle dependence of the cellular signal transformer is cos 2(psi 0 - psi). (2) The set point of the automatic controller is psi 0 = +/- 90 degrees. The cells like to orient their long axis perpendicular to the direction of the applied guiding signal. (3) The signal transformer measures the extracellular signal in a quadratic fashion. The cells cannot register the sign of the guiding field. (4) The stochastic signal in the automatic controller can be quantified by a characteristic time (approximately 130 min for fibroblasts). (5) The extracellular signal is registered in cell-made standards (ratio of the deterministic and stochastic signal equals one): 0.3 +/- 0.05 V/mm for human fibroblasts (electric field) and 85 +/- 3 microns for human fibroblasts and osteoblasts (cyclindrically bent surface). (6) The lag-time in the signal transduction system of fibroblasts is approximately 4 min.

Cell Polarity↗

[Preparing a manuscript for publication in a scientific journal].

Nowadays scientific publishing in peer reviewed international accepted journals is not easy. Rejection rates up to 75% occur. The aim of this paper is to provide guidance in the preparation of journal papers for the inexperienced scientific writer. The traditional paragraphs Abstract, Introduction, Material and Methods, Results, and Discussion are described with respect to its contents and basic message and how these sections are designed to build a logical flow. Approved suggestions for the structural outline of each paragraph are made. The significance of reference list, figures, and tables is also explained. The review of a manuscript is discussed and the criterias for acceptance of a journal paper are indicated.

Authorship↗

[Sonographic imaging of leg geometry].

Posttraumatic malalignments are a frequent sequlae of IM nailing of lower extremity fractures. Conventional US has proven to be inferior to CT determinations of tibial or femural length and torsion. A new 3-D US method is presented that allows for accurate single step determination of lower extremity length and torsion without ionizing radiation. A regular US machine with a 5 Mhz linear probe is combined with an US localizer. Reference markers affixed to the lower extremity eliminate errors associated with patient position or motion. The 3-D US method was compared against CT (Ulm's method) in the measurement of torsion and length of the tibia and femur in 50 adults and 50 children. In both methods, the maximum difference of the intraindividual torsional angles and length measurements was 7 degrees and 7 mm. The maximum standard deviation for reproducibility in length measurement was 1.6 mm and 1.5 degrees for angular torsion. The new 3-D US technique was superior to CT in terms of reliability and reproducibility. Clinical advantages of the 3-D US technique include rapidity, independence from patient motion or positioning and the avoidance of ionizing radiation. Indications for 3-D torsional and length determinations include follow-up evaluation of adult and pediatric tibial and femoral fractures, pediatric limb and gait evaluations, and osteotomy planning.

Adolescent↗

Characteristics of an extended internal fixation system for polysegmental transpedicular reduction and stabilization of the thoracic, lumbar, and lumbosacral spine.

The Kluger internal fixator, with its artificial fulcrum outside the operative site, had to be extended for multisegmental use. Three different prototypes, called Central Bar (CB), Double Bar I (DB I) and Double Bar II (DB II) were designed, which were fully compatible with the existing reduction system. To evaluate the ability of these newly developed systems to provide primary stability in a destabilized spine, their stiffness characteristics and stabilizing effects were investigated in multidirectional biomechanical stability tests and compared with those of the clinically well-known Cotrel-Dubousset (CD) system. The investigations were performed on a spine tester using freshly prepared calf spines. The model tested was that of an intact straight spine followed by a defined three-column lesion simulating the most destabilizing type of injury. Pure moments of up to 7.5 Nm were continuously applied to the top of each specimen in flexion/extension, left/right axial rotation, and left/right lateral bending. Segmental motion was measured using a three-dimensional goniometric linkage system. Range of motion and stiffness within the neutral zone were calculated from obtained load-displacement curves. The DB II attained 112.5% (P = 0.26) of the absolute stiffness of the CD system in flexion and enhanced its stability in extension by up to 144.3% (P = 0.004). In axial rotation of the completely destabilized spine, this system achieved 183.3% of the stiffness of the CD system (P < 0.001), and in lateral bending no motion was measured in the most injured specimens stabilized by the DB II. The DB I, which was the first to be designed and was considered to provide high biomechanical stability, did not attain the stiffness standard set by the CD system in either flexion/extension or axial rotation of the most injured spine. The study confirms that it is worthwhile to evaluate in vitro the biomechanical properties of a newly developed implant before its use in patients, in order to refine weak construction points and help to reduce device-related complications and to better evaluate its efficacy in stabilizing the spine.

Animals↗