PubMed Health⌕ Search

Biomedical subjects

L Cordone

Publications and source records attributed to L Cordone.

At least 37 records · Page 2Linked to original sources

Protein dynamics. Comparative investigation on heme-proteins with different physiological roles.

We report the low temperature carbon monoxide recombination kinetics after photolysis and the temperature dependence of the visible absorption spectra of the isolated alpha SH-CO and beta SH-CO subunits from human hemoglobin A in ethylene glycol/water and in glycerol/water mixtures. Kinetic measurements on sperm whale (Physeter catodon) myoglobin and previously published optical spectroscopy data on the latter protein and on human hemoglobin A, in both solvents, (Cordone, L., A. Cupane, M. Leone, E. Vitrano, and D. Bulone. 1988. J. Mol. Biol. 199:312-218) are taken as reference. Low temperature flash photolysis data are analyzed within the multiple substates model proposed by Frauenfelder and co-workers (Austin, R. H., K. W. Beeson, L. Eisenstein, H. Frauenfelder, and I. C. Gunsalus. 1975. Biochemistry. 14:5355-5373). Within this model a distribution of activation enthalpies for ligand binding accounts for the structural heterogeneity of the protein, while the preexponential factor, containing also the entropic contribution to the free energy of the process, is considered to be constant for all conformational substates. Optical spectra are deconvoluted in gaussian components and the temperature dependence of the moments of the resulting bands is analyzed, within the harmonic Frank-Condon approximation, to obtain information on the stereodynamic properties of the heme pocket. The kinetic and spectral parameters thus obtained are found to be protein dependent also with respect to their sensitivity to changes in the composition of the external medium. A close correlation between the kinetic and spectral features is observed for the proteins examined under all experimental conditions studied. The results reported are discussed in terms of differences in the heme pocket structure and in the conformational heterogeneity among the various proteins, as related to their different capability to accommodate constraints imposed by the external medium.

Animals↗

Oxygen binding to partially oxidized hemoglobin. Analysis in terms of an allosteric model.

We report on oxygen binding to partially oxidized (aquomet) hemoglobin. The fractional saturation with oxygen is evaluated by deconvoluting the optical absorption spectra, in the 500-700 nm wavelength region, in terms of oxyhemoglobin, deoxyhemoglobin and methemoglobin spectral components. Experiments have been performed with auto-oxidized samples and with samples obtained by mixing ferrous hemoglobin with fully oxidized hemoglobin (mixed samples). An increase in oxygen affinity and a decrease in cooperativity are observed on increasing the amount of ferric hemoglobin in the sample. A high cooperativity (nH approximately 2) is maintained even in the presence of 50-60% ferric hemes. Moreover, for equal amounts of methemoglobin the oxygen affinity is lower and the cooperativity higher for mixed samples than for those auto-oxidized. The results are analyzed within the framework of a modified Monod-Wyman-Changeux allosteric model taking into account the effects brought about by the presence of oxidized hemes and of alpha betta dimers. The distribution of ferric subunits within the tetramers in fully deoxygenated and fully oxygenated samples, as derived from the model, provides details on the cooperative behavior of partially oxidized hemoglobin.

Allosteric Regulation↗

Optical absorption spectra of azurin and stellacyanin in glycerol/water and ethylene glycol/water solutions in the temperature range 290-20 K.

We have measured the optical absorption spectra of azurin and stellacyanin in the wavelength range 1100-350 nm and in the temperature interval 290-20 K. Samples are protein aqueous solutions containing 65% (v/v) glycerol or ethylene glycol as cryoprotectants and remain homogeneous and transparent throughout the whole temperature range investigated. Spectra are deconvoluted into Gaussian components and the temperature dependence of the zeroth, first and second moments of the various bands is analyzed, within the harmonic Franck-Condon approximation, to obtain information on the stereodynamic properties of the active sites of these proteins. Sizable differences of the integrated intensities of all the bands with temperature are observed and are attributed to variations of the metal-ligand relative positions (i.e., deformations of the active site) that occur as the temperature is lowered. The mean effective frequency of the nuclear vibrations coupled to all the observed bands is about 150 cm(-1) for both proteins in both solvents used; this indicates that the electronic transitions from which the optical spectrum originates are substantially coupled with low-frequency vibrational modes, likely ligand-metal-ligand deformations. The relevance of the stereodynamic properties of azurin and stellacyanin, investigated in this work, to their functional behavior is also suggested.

Journal Article↗

[Dose and exposure reduction in endodontic radiology through the use of new filters].

In this study the authors discuss parameters which influence the emission spectrum of x-rays and criteria that have an influence on their distribution (anode current, tension), and they draw attention to the materials most frequently used for filter construction-niobium in particular. The authors conducted a clinical study to verify whether the use of a niobium filter mounted on an x-ray machine would decrease the amount of exposure to the patient and give a higher quality image as well, because of decreased radium diffusion which consequently diminishes the risk to the operators.

Dental Pulp Diseases↗

Interaction between external medium and haem pocket in myoglobin probed by low-temperature optical spectroscopy.

The visible absorption spectra of carbonmonoxymyoglobin in the temperature range 300 to 20 K are reported and compared with the analogous spectra of carbonomonoxyhaemoglobin. The temperature dependence of the zeroth, first and second moment of the observed bands is analysed to obtain information on the local dynamics in the proximity of the haem. Contrary to haemoglobin, the first moment of the observed bands in myoglobin is markedly affected by the solvent composition and its value saturates at temperatures at which the solvent undergoes the glass transition. These data indicate that solvent properties influence the haem pocket stereodynamics in myoglobin; moreover, the different behaviour between myoglobin and haemoglobin suggests that the process should involve the surfaces that are buried in the haemoglobin tetramer and exposed to the solvent in myoglobin, and/or the different protein compressibility.

Animals↗

Effect of organic co-solvents on the dimer/tetramer equilibrium of human haemoglobin.

We have studied the effect of organic co-solvents (monohydric alcohols and formamide) on the dimer-tetramer equilibrium of human haemoglobin by measuring the dependence of oxygen affinity upon haemoglobin concentration over a 100-fold concentration range and analysing the data with a modified Monod-Wyman-Changeux model in which the equilibrium (tetramer) in equilibrium with (dimer) + (dimer) was taken into account. This procedure enabled us to obtain the dimer-tetramer equilibrium constant and to find its dependence upon co-solvent concentration. Then by following the procedure already reported for the tense----relaxed state transition of haemoglobin, we separated the co-solvent effects into bulk electrostatic and non-bulk electrostatic (hydrophobic) contributions. We believe that our results demonstrate that during haemoglobin dissociation, just as we have already shown for the tense to relaxed state transition, both charged groups and hydrophobic surfaces became exposed to the solvent.

1-Propanol↗

Effects of organic co-solvents on the oxygen equilibrium of N-ethylmaleimide-treated human haemoglobin.

We have studied the effects of monohydric alcohols and formamide on the oxygen equilibrium of native and N-ethylmaleimide-treated human haemoglobin. Comparison of the results obtained for the two haemoglobins gives further and compelling evidence in favour of the model, proposed recently by our group, on the role played by the solvent in the conformational equilibria of haemoglobin; moreover the results provide direct functional evidence of the relevance of the electrostatic free energy of salt bridges to the T in equilibrium with R equilibrium of haemoglobin.

1-Propanol↗

Optical absorption spectra of deoxy- and oxyhemoglobin in the temperature range 300-20 K. Relation with protein dynamics.

We have studied the optical absorption spectra of human deoxy- and oxyhemoglobin in the temperature range 300-20 K and in the wavelength range 350-1350 nm. By lowering the temperature, a narrowing and a shift of all bands were observed together with a sizeable increase of the integrated intensities of the charge-transfer bands of deoxyhemoglobin. At all temperatures the spectra are in full agreement with the band assignment previously suggested in the literature and no new relevant bands have been detected for both deoxy- and oxyhemoglobin. Analysis of the first and second moment of the bands, within the framework of the harmonic Franck-Condon approximation, gave information on the dynamic properties of the heme in the heme pocket.

Freezing↗

Evaluation of hypertension and related target organ damage by average day-time blood pressure.

Aim of the present study was to verify whether average blood pressure continuously recorded throughout the day correlates with the degree of target organ damage more closely than casual pressure in hypertensive patients. The study was conducted in 102 subjects with borderline, moderate and severe hypertension. Our results confirm a closer relationship between cardiovascular complications and recorder blood pressure than casual pressure possibly because the latter less perfectly reflects the patients usual pressures which are generally lower. However our results further demonstrate that blood pressure variability also contributes to the degree of target organ damage since for equal average day-time pressures a greater severity of cardiovascular complications was observed in patients with the highest blood pressure variability and the highest peaks of pressure. These findings should be carefully considered when evaluating the effect of antihypertensive drugs.

Adolescent↗

Reliability of indirect blood pressure monitoring for the evaluation of hypertension.

To assess the reliability of the Del Mar Avionics indirect blood pressure (BP) monitoring system 15 hypertensive patients were concomitantly studied with the intraarterial Oxford system. During daytime a statistically significant correlation was found between the BP values obtained with the two systems. On the contrary during the night this correlation in most cases was not significant. However the histograms of the between-method differences were similar during the day and the night, showing that the Del Mar Avionics Pressurometer (P) performs equally well throughout the 24 hours. It is concluded that the P is reliable for continuous indirect BP monitoring and suitable for the evaluation of the efficacy of antihypertensive treatments.

Blood Pressure↗

Computer analysis of continuous direct blood pressure recording.

Blood pressure signals recorded continuously in ambulatory patients using the Oxford system were analyzed by an IBM 370 computer in order to obtain beat by beat systolic and diastolic blood pressure along 24 hour blood pressure recordings. The analogical-digital conversion of the signal and the analysis of the sphygmogram are presented and discussed. Synthesis of the several thousands data obtained in 24 hour recordings and plotting of the data for clinical purposes and pharmacological studies are also reported.

Blood Pressure↗

Oxygen affinity of bovine haemoglobin. Relevance of electrostatic and hydrophobic interactions.

We have studied the effects of organic cosolvents (monohydric alcohols and formamide) on the oxygen equilibrium of bovine haemoglobin and have compared them with the effects of the same cosolvents on the oxygen equilibrium of human haemoglobin. Our results indicate: (1) that in agreement with previous suggestions, the lower affinity of bovine haemoglobin for oxygen is not due to an increased number of salt bridges stabilizing the T structure; (2) that, following T----R transition, more hydrophobic surface is exposed to the solvent by bovine than by human haemoglobin. We suggest, therefore, that a relevant role in keeping the oxygen affinity of bovine haemoglobin lower than that of human haemoglobin is played by the higher free energy needed to expose this more hydrophobic surface to the solvent. We stress, however, that our analysis does not enable us to say which particular amino acid residues are concerned in these effects.

1-Propanol↗