Use of a tripodal mandibular subperiosteal implant with ramus hinges for facial asymmetry.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L I Linkow.
Explore the source record for details and available documents.
Some subperiosteal mandibular implants of the earlier designs failed because of bone resorption beneath the posterior portions of the implant. Conversely, bone loss was observed rarely in the anterior region. The resorption was more profound posteriorly because there can be as much as 250 lb. of biting force per square inch and the bone is more porous than in the symphyseal region, which receives about 25 lb. per square inch. The independent movements of the condyles and the inferior border of the mandible at the gonial angles have dictated the success or failure of conventional mandibular subperiosteal implants in many of the earlier designs. Often, the rigidity of the implant framework prevents its posterior portion from moving in unison with the flexion and flexibility of the condyles upon the opening and closing of the mouth. Flexure usually is 2-4 mm in range and varies according to the quality of bone, age, sex, and musculature of the patient. Approximately 2% of these patients demonstrate movements of up to 4 mm. This has influenced an altered approach to posterior design-especially with tripodal mandibular subperiosteal implants. A brief history of the contributions of the earlier pioneers and their important contributions to the subperiosteal implant follows: G. Dahl inserted the first mandibular subperiosteal implant and was awarded his patent in 1941. Gershkoff and Goldberg, were the first to report clinical cases with mandibular subperiosteal implants in the United States. N. Berman reported on a direct bone impression of the mandible and transosseous wiring of the implant to the bone for stabilization. I. Lew introduced his own surgical bone impression technique for the mandibular subperiosteal implant and had published case histories on maxillary and mandibular implants. B. D. Weinberg reported an early unilateral subperiosteal implant consisting of a latticework portion that seated over the bone connected to the protruding post by four uprights. Leonard I. Linkow reported on the posterior unilateral mandibular subperiosteal implant. He followed up with a 5-year report, an 8-year follow-up report, and a 12-year report. R. L. Bodine reported his experiences with mandibular subperiosteal implants. A. N. Cranin and P. Schnitman introduced the Brookdale bar for an improved support of an overdenture for the mandibular subperiosteal implants. L. I. Linkow made some significant changes in the mandibular subperiosteal implant. D. D'Alise reported on the O-ring design for retention of implant dentures. R. A. James reported on the support system and perigingival mechanism surrounding oral implants and changed the subperiosteal based on peri-implant tissue behavior. L. I. Linkow reported on an entirely new mandibular tripodal design concept as well as a distinct change in the surgical protocol for obtaining the bone impressions without exposing those parts of the body of the mandible from the mental nerves to the ascending rami.
A tripodal mandibular subperiosteal dental implant is a three piece cast metal framework that fits on the residual ridge beneath the periosteum and provides support for a dental prosthesis by means of posts or other mechanisms protruding through the oral mucosa. This implant is indicated in patients with advanced atrophy of the mandible where the unstable alveolar bone has completely disappeared, leaving in place the more stable basal bone with specific anatomical contours. The authors present their experience of 317 cases carried out in three different centers related to this implant modality and underline the importance of the basic anatomic, physiologic, and medical knowledge required to optimize the results.
A maxillary full arch subperiosteal implant consists of a metallic framework that rests closely on the atrophied residual ridge beneath the mucoperiosteum and offers support for a dental prosthesis by means of posts or bars with O-ring protrusions or internal clip attachments. The maxillary subperiosteal implant is indicated for those patients presenting with advanced atrophy of the maxilla leaving the patient with three existing stable dense bony areas (the anterior nasal spine, the canine eminences, and the palatal surface of the existing crest) for its support. Over 300 cases with up to 12 years in function are presented. The importance of the basic anatomic and physiologic background required to optimize results are emphasized. The first 600+ subperiosteal implant cases that were placed prior to 1985 showed considerably lower success rates.
Explore the source record for details and available documents.
However, accepting the route of dental implantology's evolution, and with a positive outlook for the future, the author believes that the four types of root form implants described here will be utilized. This belief in their application, has come from vast experience placing thousands of implants into various types of bone. It is now up to those dentists who have become exclusively involved with one type of root form implant to reflect on the ideas expressed in this article, and start to challenge what has been considered the "norm", and consider treating their patients with implants that will most likely prove to be superior in design and function.
The blade-/plate-form implant is the only endosseous implant which has proved to be successful under three different types of integration: fibrous integration, when the layer of fibrous or collagenous tissue interspersed between implant and bone is less than 125 microns; fibro-osseous integration, when there is a combination of thinly defined fibrous connection with 22% or less direct bone contact with the implant; and osseous integration, when there is 23% or more direct bone-to-implant contact, with no evidence of fibrous connective tissue anywhere. The blade implant is an unique versatile device which has passed with success the test of time (some of them being in function for as long as 28 years) and deserves more attention from implantologists around the world.
An unique press fit/tap-in, anti-rotational cylinder implant is described. It has an apical core and side vents which encourage bone growth, and its tapered fins provide a self-tapping mechanism, thus creating a firm anti-rotational mechanical anchorage from the moment of its insertion. Preliminary clinical trials have proved to be very successful, especially in poor bone density areas.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Problem-solving and treating various types of infections that can cause alveolar bone loss or inferior alveolar nerve dehiscences by failed implants or teeth are discussed. The reasons why implants fail from either surgical or prosthetic errors are reviewed. Treatment remedies which have solved numerous implant-related problems are offered. The eclectic, multi-modal implant surgical and prosthetic abilities of the clinician necessary today for successfully treating patients presenting with troubled or infected implants are reviewed.
As more practitioners are using implants in their practice, more questions have arisen regarding the use of these devices. One very important factor is the type of bone-implant interface obtained. The more inert and stable over time the metal is, the more we can control the overall success of the implant. Plasma glow discharge treatment is an ideal technique to increase the wettability of the metal and to insure a sound bone-implant interface. This article is an introduction to the use of plasma glow discharge treatment on dental implants.
A blade implant that was retrieved in 1990 after 231 months of clinical function (since 1971) was analyzed with respect to clinical, histological, and biomechanical characteristics. The implant clinical records demonstrated no abnormalities or pathological lesions over the tenure of treatment. The bone to implant interface showed a mixture of interfacial tissue components and conditions with adequate direct bone contact (46.4 to 82.3 percent) for classification as osseointegrated. The abutment fracture leading to removal was characterized as a cyclic fatigue mechanism and the distribution of tissue components along the interface could not be correlated with specific biomechanical loading directions. This report considers the clinical and biomechanical records as they relate to the detailed histological investigation.
Explore the source record for details and available documents.
An implant quotient (IQ) has been proposed to help clinicians identify the 24 factors that can affect the potential long-term success of endosseous dental implants. Maximizing the positive factors and minimizing the negative factors will result in relatively high values for the theoretical IQ. Long-term success is directly proportional to the resultant value of the IQ. The greater the value of the IQ, the better the possibility for long-term success. The length of healing time and the necessity for submerged healing are indirectly proportional to the resultant value of the IQ. The greater the value of the IQ, the shorter the healing time before loading an endosseous implant may be. The greater the value of the IQ, the less necessary it becomes to submerge the healing implant.