L Kirkup

Publications and source records attributed to L Kirkup.

10 recordsLinked to original sources

Comparison of equations describing band broadening in high-performance liquid chromatography.

Several models are well established that describe band broadening in gas and liquid chromatography, including those due to Van Deemter and Knox. Comparison of competing models is complicated if raw data are noisy or if the equations to be fitted to data contain many adjustable parameters. This paper describes a comparison of fitting the Van Deemter, Knox and other equations to low noise data gathered during the separation of propyl- and methylparaben by HPLC. Equations are compared using established statistical methods, including analysis of residuals, inference of parameter estimates and Akaikes Information Criterion for model identification. This work indicates that equations that account for non-linear band broadening at elevated mobile phase velocities are more successful at describing the relationship between height equivalent to a theoretical plate, H, and the velocity of the mobile phase, u.

Chromatography, High Pressure Liquid↗

Control of a hand grasp neuroprosthesis using an electroencephalogram-triggered switch: demonstration of improvements in performance using wavepacket analysis.

Volitionally modulated electroencephalographic (EEG) waves were monitored for the purpose of controlling a hand neuroprosthesis in people with tetraplegia. The region of the EEG signal spectrum monitored was the occipital alpha wave (8-13 Hz), and volitional modulation was achieved with the opening and closing of the eyes. In a set of 13 trials evaluated, a subject with tetraplegia successfully completed ten trials undertaking stimulated grasp and release using the EEG-triggered switch. EEG signal data recorded during the 13 trials were also post-processed off-line using wavepacket analysis. Following this signal processing, the speed and reliability of the EEG-triggered switch, when operated by the subject with tetraplegia, was significantly improved (p < 0.002). Such improvements provide system performance that is likely to be acceptable to a neuroprosthesis user during activities of daily life.

Electric Stimulation↗

Detection of alpha electro-encephalogram onset following eye closure using four location-based techniques.

Detection of alpha activity in the electro-encephalogram (EEG) has been used extensively in neurophysiological studies. Previously applied alpha parameterisation techniques, which utilise the amplitude information from a pair of differential electrodes, are often susceptible to interference from artifact signals. This is an issue if the purpose of detecting the change in alpha wave synchronisation is the basis of an environmental control system (ECS). An alternative approach to alpha activity detection is proposed that utilises the information from an array of electrodes on the scalp to estimate the apparent location of alpha activity in the brain. Four methods are described that successfully detect the onset of alpha EEG increase following eye closure by monitoring the apparent location of alpha activity in the head. The methods use Bartlett beamforming, a four-sphere anatomical head model, the MUSIC algorithm and a new 'power vector' technique. Of the methods described, the power vector technique is found to be the most successful. The power vector technique detects the alpha increase associated with eye closure in times that are, on average, 33% lower than previously applied alpha detection methods.

Algorithms↗

Effect of luminance level on electro-encephalogram alpha-wave synchronisation.

A control system for the remote activation of electronic devices, based on alpha-wave synchronisation, must be robust over a wide range of lighting conditions. This study investigates the effect that low light levels have on the increase in amplitude of the occipital alpha-wave component of the human electro-encephalogram spectrum in response to eye closure. Measurements of the time required for the amplitude of the occipital alpha wave to increase above a predetermined threshold, upon eye closure, were taken from 21 subjects and at four illuminances, ranging from 2 x 10(-1) lx to 2 x 10(-5) lx. The light source used to provide these illuminances was a featureless, uniformly illuminated white paper that subtended 30 degrees of the visual field. Statistical analysis showed that the time to exceed threshold (TTET) upon eye closure was not independent (p< 0.001) of illuminance, and that the main source of this lack of independence occurred at the lowest illuminance, 2 x 10(-5) lx. At this luminance, the median TTET value was 15.0s. However, at 2 x 10(-4) lx, the median value of the TTET was 4.2s. This is a sufficiently short time for device activation, and therefore a control system based on alpha-wave synchronisation is functional at very low light levels.

Adolescent↗

The effectiveness of activating electrical devices using alpha wave synchronisation contingent with eye closure.

Increases in alpha wave amplitude occur with eye closure (EC) and decreases occur when the eyes are opened (EO). The research reports in this paper emphasise effectiveness of people using these alpha wave changes to activate electrical devices. Effectiveness was measured in terms of time taken and errors made when selecting the correct device. Ten non-disabled subjects significantly decreased the time taken and errors made to activate correctly a device using a six-option environmental control system (ECS) in the laboratory. In addition, a severely disabled person was shown to use the ECS successfully to control her television in her home environment. This research demonstrates that alpha wave manipulation contingent with EC and EO can be the basis for a reliable and quick switching system for controlling electrical devices. Applications to disability are discussed.

Adult↗

A direct comparison of wet, dry and insulating bioelectric recording electrodes.

Alternatives to conventional wet electrode types are keenly sought for biomedical use and physiological research, especially when prolonged recording of biosignals is demanded. This paper describes a quantitative comparison of three types of bioelectrode (wet, dry and insulating) based on tests involving electrode impedance, static interference and motion artefact induced by various means. Data were collected simultaneously, and in the same physical environment for all electrode types. Results indicate that in many situations the performance of dry and insulating electrodes compares favourably with wet electrodes. The influence of non-stationary electric fields on shielded dry and insulating electrode types was compared to wet types. It was observed that interference experienced by dry and insulating electrode types was 40 dB and 34 dB less than that experienced by wet electrode types. Similarly, the effect of motion artefact on dry and insulating electrodes was compared to wet types. Artefact levels for dry and insulating electrodes were significantly higher than those for wet types at the beginning of trials conducted. By the end of the trial periods artefact levels for dry and insulating types were lower than wet electrodes by an average of 8.2 dB and 6.8 dB respectively. The reservations expressed in other studies regarding the viability of dry and insulating electrodes for reliable sensing of biosignals are not supported by the work described here.

Artifacts↗

Real time impedance plots with arbitrary frequency components.

Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample which has nonstationary electrical characteristics. The system reported here obtains impedance spectra by applying a digitally constructed waveform consisting of many frequency components. This allows impedance values to be measured at a number of frequencies simultaneously. Sample data are provided and compared with data obtained using similar square wave techniques.

Calibration↗

Three methods compared for detecting the onset of alpha wave synchronization following eye closure.

Recent work indicates that the variation in the occipital alpha wave component of the EEG spectrum, controlled through eye closure, can be used by an untrained person to effect reliable activation of electrical devices. Here we describe and compare three real-time strategies, based on analogue and digital signal processing methods, of detecting the onset of alpha wave synchronization during eye closure. The goal of this work is to establish a method which satisfies the condition of rapid detection of alpha wave enhancement, thereby allowing for the efficient activation of devices, while simultaneously registering few or no false positives due to the natural variation in the alpha signal with eyes open. This work, based on measurements on 15 subjects in the age range 12 to 40 years, indicates that renal-time analysis of the EEG power spectrum provides for rapid detection of the onset of alpha wave synchronization while maintaining low counts of false positives.

Alpha Rhythm↗

EEG-based system for rapid on-off switching without prior learning.

Details are reported of an EEG-based system that permits a person rapidly and reliably to switch on and off electrical devices without prior learning. The system detects and utilises increases in the amplitude of the alpha component of the EEG spectrum that occur when people close their eyes for more than 1 s. In addition to conventional signal-processing elements, the system incorporates a module for suppressing switching at the output of the system when predetermined noise threshold levels (such as those due to sources of EMG) are exceeded. This work indicates that a majority, perhaps in excess of 90%, of the adult population can demonstrate the control necessary to operate an electrical device or appliance using this system. It is indicated that multi-level switching and quasi-continuous control options are feasible with further development of the system. This work has implications for the design of a system that could be used, for example, to assist the infirm or severely physically disabled to effect greater control over their environment.

Adult↗

A demonstration of pharmacokinetics and physiological modelling using a microcomputer for data capture and analysis.

We describe a simple and inexpensive demonstration of mass transport and exchange using dye clearance from a hydrodynamic model. A microcomputer was used for data acquisition and storage, non-linear least squares curve fitting, compartmental analysis and parameter estimation. The system is useful for demonstrating the indicator-dilution technique for fluid volume measurement and compartmental analysis in pharmacokinetics.

Algorithms↗