Publications and source records attributed to L Koltun.

2 recordsLinked to original sources

Granulopoiesis in "preleukemic" mice with anemia induced by Rauscher leukemia virus, variant a.

To understand further the hematopoietic dyscrasias induced by a variant (a) of Rauscher leukemia virus (RLV), we used Escherichia coli endotoxin to stress the hematopoietic system of control and RLV/a-infected BALB/c mice. During the preleukemic stages of virus infection, there was slight splenomegaly without peripheral blood erythroblastosis. Granulocyte release and tissue mobilization mechanisms appeared unaffected by the RLV/a infection. Both RLV/a-infected and control mice reacted to endotoxin with peripheral granulocytosis and peritoneal granulocyte mobilization, though the circulating granulocyte levels in RLV/a-treated mice initially were lower than those in controls. Spleen of RLV/a-infected animals were larger than those of controls, but both responded to endotoxin with elevated numbers of granulocytes and erythroblasts. Since numbers of bone marrow erythroblasts in both groups of mice were decreased after endotoxin, stem cell competition and/or shunting of stem cells from marrow to spleen may have been involved. Endotoxin also induced rapid falls in hematocrit levels in both groups. These studies suggested that RLV/a-infected mice can be a model to study 1) erythropoietic dysfunction uncomplicated by defective granulopoietic release and tissue mobilization control mechanisms, and 2) progression of evolving granulocytic leukemia.

Anemia

A microprocessor temperature-controlled air delivery system for dentinal hypersensitivity testing.

A new microprocessor temperature controlled air delivery system for determining cold and warm temperature thresholds of dentinal hypersensitivity has been designed and built. The temperature range of the unit is -5 degrees to + 85 degrees C. Air is delivered from a typical dental unit air syringe nozzle at a relatively gentle flow rate of 0.2 cu ft/min at operator selected temperatures, with an accuracy of +/- 0.2 degrees C. Within seconds, 1 degree to 5 degrees temperature increments or decrements are accomplished. Larger, i.e., 20 degree increments or decrements, require approximately 15 seconds. The unit can operate from standard 110 V/60 Hz or 230 V/50 Hz outlets and requires a source of compressed air at 60 psig, equivalent to that provided by dental operatory-type air compressors. This report provides a description of the unit, its operation, and data from two clinical studies in which it was used successfully to determine temperature thresholds of dentinal hypersensitivity.

Dentin Sensitivity