PubMed Health⌕ Search

Biomedical subjects

L W Brackenbush

Publications and source records attributed to L W Brackenbush.

4 recordsLinked to original sources

Characterising the energy deposition events produced by trapped protons in low earth orbit.

Men and equipment in space vehicles in low earth orbit are exposed to a wide variety of radiations, but the majority of the dose is due to trapped protons, which have energies of the order of 100 MeV and are low LET particles. These high energy particles produce nuclear fragmentation with high LET secondaries that may be responsible for a significant fraction of dose equivalent. In order to understand better the biological effectiveness of this radiation environment, a portable tissue equivalent proportional counter spectrometer has been developed that automatically records the distribution of energy in a small tissue-like site as a function of time. This instrument weighs about 700 g and will be flown on a number of future space shuttle flights.

Cosmic Radiation↗

Microdosimetric basis for exposure limits.

Consideration of the energy deposited by ionizing radiation in microscopic volumes has led to new insights into dosimetric concepts at the levels of interest in radiation protection. Large amounts of energy are deposited by the passage of low linear-energy-transfer (LET)-charged particles through small volumes. If a typical cell nucleus is considered to be about 7 micron, at an exposure rate of 2.5 X 10(-1) C kg-1 h-1 (1 mR hr-1) from a 60Co irradiation, the average cell nucleus receives one energy deposition event every 12.5 d. Biological processes, which modify radiation damage, typically occur in a few minutes to a few hours. Thus, at occupational exposure levels it is probably the irreparable or misrepaired effects of irradiation that determine the biological consequences. One goal of dosimetry is to measure the incident radiation, making it possible to predict biological risk and set meaningful exposure limits. These measurements must relate to the energy depositions that are responsible for radiation effects at low dose rates, yet the dosimetry system must not be excessively complex to allow use by operational health physicists. Furthermore, our description of the irradiation should be directly measurable. The use of quality factors based upon the energy deposition in a 1-micron-diameter volume of tissue as prescribed in International Commission on Radiation Units Report No. 40 (Joint Task Group 1986) satisfies these requirements. Instrumentation based upon measurement of lineal energy has already been successfully used in health-physics applications. Future changes in the quality factor can be accommodated by changing the algorithm in these microprocessor-based instruments.

Dose-Response Relationship, Radiation↗