Abstract

Consideration of the energy deposited by ionizing radiation in microscopic volumes has led to new insights into dosimetric concepts at the levels of interest in radiation protection. Large amounts of energy are deposited by the passage of low linear-energy-transfer (LET)-charged particles through small volumes. If a typical cell nucleus is considered to be about 7 micron, at an exposure rate of 2.5 X 10(-1) C kg-1 h-1 (1 mR hr-1) from a 60Co irradiation, the average cell nucleus receives one energy deposition event every 12.5 d. Biological processes, which modify radiation damage, typically occur in a few minutes to a few hours. Thus, at occupational exposure levels it is probably the irreparable or misrepaired effects of irradiation that determine the biological consequences. One goal of dosimetry is to measure the incident radiation, making it possible to predict biological risk and set meaningful exposure limits. These measurements must relate to the energy depositions that are responsible for radiation effects at low dose rates, yet the dosimetry system must not be excessively complex to allow use by operational health physicists. Furthermore, our description of the irradiation should be directly measurable. The use of quality factors based upon the energy deposition in a 1-micron-diameter volume of tissue as prescribed in International Commission on Radiation Units Report No. 40 (Joint Task Group 1986) satisfies these requirements. Instrumentation based upon measurement of lineal energy has already been successfully used in health-physics applications. Future changes in the quality factor can be accommodated by changing the algorithm in these microprocessor-based instruments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L W Brackenbush, L A Braby. 1988. Microdosimetric basis for exposure limits.. https://doi.org/10.1097/00004032-198808000-00017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗