PubMed Health⌕ Search

Biomedical subjects

Lars Wallman

Publications and source records attributed to Lars Wallman.

3 recordsLinked to original sources

On-chip microextraction for proteomic sample preparation of in-gel digests.

Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.

Electrophoresis, Gel, Two-Dimensional↗

Improved chip design for integrated solid-phase microextraction in on-line proteomic sample preparation.

A recently introduced silicon microextraction chip (SMEC), used for on-line proteomic sample preparation, has proved to facilitate the process of protein identification by sample clean up and enrichment of peptides. It is demonstrated that a novel grid-SMEC design improves the operating characteristics for solid-phase microextraction, by reducing dispersion effects and thereby improving the sample preparation conditions. The structures investigated in this paper are treated both numerically and experimentally. The numerical approach is based on finite element analysis of the microfluidic flow in the microchip. The analysis is accomplished by use of the computational fluid dynamics-module FLOTRAN in the ANSYS software package. The modeling and analysis of the previously reported weir-SMEC design indicates some severe drawbacks, that can be reduced by changing the microextraction chip geometry to the grid-SMEC design. The overall analytical performance was thereby improved and also verified by experimental work. Matrix-assisted laser desorption/ionization mass spectra of model peptides extracted from both the weir-SMEC and the new grid-SMEC support the numerical analysis results. Further use of numerical modeling and analysis of the SMEC structures is also discussed and suggested in this work.

Miniaturization↗

Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium.

Square-shaped silicon or titanium implants with plane or porous surfaces surrounded by a rim of silicone were implanted in the rat abdominal wall for evaluation of the tissue response after one, six, or 12 weeks. Cell damage was identified as increased membrane permeability using fluorescence microscopy by injection of propidium iodide prior to the killing of the rats. Capsule thickness and immunohistochemical quantification of macrophages were used as a further measure of the foreign-body reaction. There were no significant differences in capsular cell densities for macrophages, total cells (macrophages, fibroblasts, and other cells), or necrotic cells at the different time points for the four surfaces studied. However, significant differences in the kinetics of the response were found between plane surfaces compared with porous ones. Both types of plane surfaces developed a significant increase in capsule thickness over time in contrast to the porous implants. Porous silicon displayed a significant decrease in total cells in the reactive capsule over time. Furthermore, porous silicon and titanium surfaces displayed a significant decrease in total cell numbers at the implant interface between six and 12 weeks. The present study demonstrated that implanted silicon elicited soft-tissue reactions comparable to that of titanium.

Abdominal Muscles↗