Template synthesis of highly ordered Prussian blue array and its application to the glucose biosensing.

In this paper, we propose a strategy to form nanoelectrode arrays by electrochemical deposition of the Prussian blue (PB) through highly ordered porous anodic alumina (PAA) membrane. The structure and morphology of the nanoarrays were characterized by scanning electron microscopy (SEM). As the highly ordered PB arrays can behave as an ensemble of closely spaced but isolated nanoelectrodes, the nanostructured PB arrays are successfully applied to improve the analytical performances of glucose by electrocatalytic reduction enzymatically liberated H(2)O(2). The resulting PB based nanoelectrode arrays show a wide linear calibration range over three orders of magnitude of glucose concentrations (5.0 x 10(-6) to 8.0 x 10(-3)M) and a low detection limit of 1 microM. Moreover, the biosensor exhibits other good characteristics, such as short response time, high selectivity, excellent operation stability. In addition, effects of the glucose oxidase (GOx) loading, applied potential and pH on the biosensor performance were also discussed.

Biosensing Techniques↗

Simultaneous determination of 5-hydroxyindoleacetic acid and 5-hydroxytryptamine in urine samples from patients with acute appendicitis by liquid chromatography using poly(bromophenol blue) film modified electrode.

The fabrication and application of a novel electrochemical detection (ED) system with a poly(bromophenol blue) (PBPB) film chemically modified electrode (CME) for high performance liquid chromatography (HPLC) were described. The electrochemical behaviors of 5-hydroxytryptamine (5-HT) and 5-hydroxyindoleacetic acid (5-HIAA) at this CME were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the PBPB CME efficiently exhibited electrocatalytic effect on the current responses of 5-HT and 5-HIAA with relatively high sensitivity, stability and long life of activity. In HPLC-ED, the two analytes had good and stable current responses at the CME and their linear ranges were over four orders of magnitude (R> or =0.9992) with the detection limits being 0.25 nmol L(-1) for 5-HT and 0.50 nmol L(-1) for 5-HIAA. The application of this method for the determination of 5-HT and 5-HIAA in urine samples from patients with acute appendicitis (AA) was satisfactory.

Acute Disease↗

Fabrication of TiO2/Ti electrode by laser-assisted anodic oxidation and its application on photoelectrocatalytic degradation of methylene blue.

A TiO2/Ti mesh electrode by laser calcination was prepared in this article. The resulting TiO2 film was investigated by X-ray diffraction (XRD), atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS), and it illuminated that the prepared electrode mainly consisted of anatase TiO2 nanoparticles on its surface and exhibited a superior photocatalytic activity. The photodegradation of methylene blue (MB) using the proposed electrode under different experimental conditions was investigated in terms of both UV absorbance at 664 nm and chemical oxygen demand (COD) removal. The electrical bias applied in photoelectrocatalytic (PEC) oxidation was also studied. The experimental results showed that under the optimal potential of +0.50 V (versus SCE), UV absorbance and COD removal during the photodegradation of MB by the proposed TiO2/Ti mesh electrode were 97.3% and 87.0%, respectively. Through the comparison between photocatalytic (PC) oxidation and photoelectrocatalytic (PEC) oxidation, it was found that PEC oxidation was a convenient and effective way to mineralize the organic matters and that laser-treated photoelectrode exceeded the oven-treated one.

Catalysis↗

Determination of dopamine in rat striatum by microdialysis and high-performance liquid chromatography with electrochemical detection on a functionalized multi-wall carbon nanotube electrode.

High performance liquid chromatography coupled with microdialysis sampling and electrochemical detection (HPLC-ECD) has been used to determine dopamine (DA). In the HPLC-ECD a multi-wall carbon nanotube electrode chemically modified with carboxyl groups (MWNT-COOH CME) was used as the working electrode for determination of DA. The results indicated that the MWNT-COOH CME enabled efficient electrocatalytic oxidation of DA with relatively high sensitivity and stability and long life. Peak currents for dopamine were linearly dependent on concentration in the range 5.0 x 10(-9) to 5.0 x 10(-5) mol L(-1) and the calculated detection limit (S/N=3) was 2.5 x 10(-9) mol L(-1). The method had been successfully used to measure dopamine in rat striatal microdialysate. To study the physiological effect of nitric oxide (NO) on striatal release of DA, 0.5 mmol L(-1) sodium nitroprusside (SNP) was a continuously perfused into rat striatum. This resulted in a 46% increase in DA basal level.

Animals↗

Glucose biosensor based on Au nanoparticles-conductive polyaniline nanocomposite.

In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).

Aniline Compounds↗

Nanostructured electrode based on multi-wall carbon nanotubes/Pt microparticles nanocomposite for electrochemical determination of thiols in rat striatum by high performance liquid chromatography separation.

In this paper, multi-wall carbon nanotubes (MWNTs)/Pt microparticles nanocomposite was prepared by electrodepositing Pt microparticles onto the MWNTs matrix. The surface of glassy carbon electrode was modified with this kind of nanocomposite for measurement of thiols, such as L-cysteine (L-Cys) and glutathione (GSH). Compared with the MWNTs or Pt microparticles modified electrode, the nanocomposite modified electrode exhibited high sensitivity and good stability for detection of thiols. According to the results of experiments, the peak currents of L-Cys and GSH are linear with their concentrations and the detection limits (S/N=3) are 2.9 x 10(-8) mol/L and 4.5 x 10(-8) mol/L, respectively. Coupled with microdialysis, the method has been successfully applied to the determination of these two thiols in rat striatal microdialysates.

Animals↗

Preparation and application of TiO2 photocatalytic sensor for chemical oxygen demand determination in water research.

In this work, a TiO(2) photocatalytic sensor was prepared and utilized into flow injection analysis (FIA) for chemical oxygen demand (COD) determination. With a positive bias potential of 0.4V (vs. Ag/AgCl) applied to the sensor and a 12-W quartz UV lamp illuminating it, photocurrent, due to the charge transfer at the interface of TiO(2) sensor and the passing solution, was recorded and its change (deltaI(Photo)) caused by the detected sample was calculated to characterize the COD value of the sample. Under the optimizing conditions, the sensor responded linearly to the COD of D-glucose solution in the range of 0.5-235 mg/L, with a linear correlation coefficient of 0.9998. Its application in artificial wastewater analysis has achieved results in good agreement with those from the conventional dichromate method; meanwhile, the process requires no hypertoxic reagents and less analysis time, suggesting that it would be another appropriate method for COD determination in water assessment.

Catalysis↗

Liquid chromatography with amperometric detection at a nano crystalline Ce-doped lead dioxide film modified electrode for determination of (R)-Salsolinol, (R)-N-methylsalsolinol and monoamine neurotransmitters in Parkinsonian patients' cerebrospinal fluid.

The fabrication and application of a novel electrochemical detector (ED) with nano crystalline Ce-doped lead dioxide film chemically modified electrode (CME) for liquid chromatography (LC) were described. The Ce-doped PbO(2) film was characterized by X-ray diffractometer (XRD) and scanning tunnel microscope (STM). The electrochemical behaviors of (R)-Salsolinol ((R)-Sal) at the CME were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the CME exhibited an efficiently electrocatalytic effect on the current responses of (R)-Sal, (R)-N-methylsalsolinol ((R)-NMSal) and monoamine neurotransmitters. In LC-ED, all (R)-Sal, (R)-NMSal, dopamine (DA), norepinephrine (NE), 3-methoxy-4-hydroxyphenylglycol (MHPG), 3,4-dihydroxyphenylacetic acid (DOPAC), 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA) had good and stable current responses at the CME. The linear ranges of the nine analytes were over three orders of magnitude (R(2) > 0.995). The application of this method coupled with microdialysis sampling for the determination of (R)-Sal, (R)-NMSal and monoamine neurotransmitters in Parkinsonian patients' cerebrospinal fluid (CSF) was satisfactory.

Chromatography, Liquid↗

Determination of thiol compounds in rat striatum microdialysate by HPLC with a nanosized CoHCF-modified electrode.

A cobalt hexacyanoferrate (CoHCF) nanoparticle (size ca. 60 nm) chemically modified electrode (CME) was fabricated and the electrochemical behavior of thiols at this nanosized CoHCF CME was studied. In comparison with a bare glassy carbon (GC) electrode and with a general CoHCF CME which was electrode-posited in the traditional manner, the present nanosized CoHCF CME efficiently performed electrocatalytic oxidation for glutathione (GSH) and L-Cysteine (L-Cys) with relatively high sensitivity, outstanding stability, and long-life. Combined with high-performance liquid chromatography (HPLC), the nanosized CoHCF CME was used for electrochemical determination (ECD) of GSH and L-Cys. The peak currents were a linear function of concentrations in the range 2.0 x 10(-7) to 2.0 x 10(-4) mol L(-1) for both GSH and L-Cys, with detection limits of 1.2 x 10(-7) and 1.0 x 10(-7) mol L(-1), respectively. Coupled with microdialysis sampling, the HPLC-ECD system has been successfully used to assess the GSH and L-Cys content of rat striatum.

Animals↗

Photocatalytic degradation of organic wastes by electrochemically assisted TiO2 photocatalytic system.

Photocatalytic degradation of organic wastes with nanosized titanium dioxide particles has been studied for a long time in order to offer an appropriate method for wastewater treatment, but its practical application is greatly limited by the slow process. In this work, an electrochemically assisted TiO2 photocatalytic system was set-up by combining a TiO2 photocatalytic cell with a three-electrode potentiostatic unit. The composite system revealed high photocatalytic activity towards organic wastes mineralization. After continuous treatment for 0.5 h, the maximum absorption of rhodamine 6G (R-6G) was reduced by more than 90%; chemical oxygen demand (COD) and biochemical oxygen demand (BOD5) of textile dye wastewater (TDW) were decreased by 93.9 and 88.7%, respectively. The biodegradability of TDW was also improved because the COD/BOD5 ratio decreased from 2.1 to 1.2. All these results indicated that the composite system could be used for effective organic wastes mineralization or as a feasible detoxification and color removal pretreatment stage for biological post treatment.

Catalysis↗

Liquid chromatography with amperometric detection using functionalized multi-wall carbon nanotube modified electrode for the determination of monoamine neurotransmitters and their metabolites.

The fabrication and application of a novel electrochemical detection (ED) method with the functionalized multi-wall carbon nanotubes (MWNTs) chemically modified electrode (CME) for liquid chromatography (LC) were described. The electrochemical behaviors of dopamine (DA) and other monoamine neurotransmitters at the CME were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The results indicated that the CME exhibited efficient electrocatalytic effects on the current responses of monoamine neurotransmitters and their metabolites with high sensitivity, high stability and long-life activity. In LC-ED, DA, norepinephrine (NE), 3-methoxy-4-hydroxyphenylglycol (MHPG), 3,4-dihydroxyphenylacetic acid (DOPAC), 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA) had good and stable current responses at the CME. The linear ranges of seven analytes were over four orders of magnitude and the detection limits were 2.5 x 10(-10) mol/l for DA, 2.5 x 10(-10) mol/l for NE, 5.0 x 10(-10) mol/l for MHPG, 3.0 x 10(-10) mol/l for DOPAC, 3.5 x 10(-10) mol/l for 5-HT, 6.0 x 10(-10) mol/l for 5-HIAA, 1.25 x 10(-9) mol/l for HVA. The application of this method coupled with microdialysis sampling for the determination of monoamine neurotransmitters and their metabolites in Parkinsonian patients' cerebrospinal fluid was satisfactory.

Biogenic Monoamines↗

Application of a single electrode, modified with polydiphenylamine and dodecyl sulfate, for the simultaneous amperometric determination of electro-inactive anions and cations in ion chromatography.

An amperometric sensor with a single working electrode for simultaneous determination of electro-inactive anions and cations, e.g. SO4(2-), Cl(-), NO3(-), Na(+), NH4(+), K(+), Mg(2+) and Ca(2+), was designed as a detector in ion chromatography. The modification of its working golden electrode was based on the incorporation of dodecyl sulfate into polydiphenylamine by electropolymerization of diphenylamine in the presence of sodium dodecylsulfate. In ion-exclusion/cation-exchange chromatography, a set of well defined peaks of these anions and cations was obtained at the working potential, +1.35 V (vs. saturated calomel electrode) using a citric acid solution as eluent. The common anions and cations in mineral water samples were determined using this ion-chromatographic system with satisfactory results.

Anions↗

Simultaneous determination of the monoamine neurotransmitters and glucose in rat brain by microdialysis sampling coupled with liquid chromatography-dual electrochemical detector.

A new type of chemically modified electrode based ring-disk electrode as the dual electrochemical detector (DECD) for high-performance liquid chromatography (HPLC) to simultaneously determine the monoamine neurotransmitters and glucose is described. The ring electrode was modified with an ion-exchange polymer-overoxidized polypyrrole (OPPy) and the disk electrode was modified with nano Au colloid and glucose oxidase (GOD). The electrochemical behaviors of dopamine (DA) and ascorbic acid (AA) at the OPPy chemically modified electrode (CME) were investigated by differential pulse voltammetry (DPV). It was found that the CME could permeate dopamine cations and repelled the ascorbate anions, which could be used to determine the monoamine neurotransmitters and avoid the interference of AA. The electrochemical behavior of glucose at the Nafion/GOD-Au colloid/GC CME was investigated by amperometry and flow injection analysis (FIA). It was found that the sensitivity of the CME increased apparently in determination of glucose. In order to obtain better separation and current responses of the analytes in HPLC-DECD, several operational parameters have been investigated. Under the optimum conditions, the method showed good stability and reproducibility. The application of this method coupled with microdialysis sampling for in vivo simultaneous determination of monoamine neurotransmitters and glucose in rat brain was satisfactory.

Animals↗

On-line biosensors for simultaneous determination of glucose, choline, and glutamate integrated with a microseparation system.

An effective microseparation system integrated with ring-disc electrodes and two microfluidic devices was fabricated for in vivo determination using a microdialysis pump. The major interference of ascorbic acid (AA) was excluded by direct oxidation with ascorbate oxidase. Glucose, glutamate, and choline were successfully determined simultaneously through the biosensors modified with a bilayer of osmium-poly(4-vinylpyridine)gel-horseradish peroxidase (Os-gel-HRP)/glucose oxidase (GOD), glutamate oxidase (GlutaOD) or choline oxidase (ChOD). To stabilize the biosensors, 0.2% polyethylenimine (PEI) was mixed with the oxidases. The cathodic currents of glucose, glutamate, and choline biosensors started to increase after the standard solutions were injected into the microseparation system. The on-line biosensors show a wide calibration range (10(-7)-10(-5) mol/L) with a detection limit of 10(-8) mol/L at the working potential of -50 mV. The variations of glucose, glutamate, and choline were determined simultaneously in a free moving rat when we perfused the medial frontal cortex with 100 micro mol/L N-methyl-D-aspartate (NMDA) solution, which is the agonist of the NMDA receptor.

Alcohol Oxidoreductases↗

Application of nano TiO(2) towards polluted water treatment combined with electro-photochemical method.

A novel composite reactor was prepared and studied towards the degradation of organic pollutants in this work. In the reactor, a UV lamp was installed to provide energy to excite nano TiO(2), which served as photocatalyst, leading to the production of hole-electron pairs, and a three-electrode electrolysis system was used to accumulate H(2)O(2) which played an important role in the degradation process. The reactor was evaluated by the degradation process of rhodamine 6G (R-6G), and the data obtained in the experiments showed that the combination of the photochemical and electrochemical system raised the degradation rate of R-6G greatly; the working mechanism of the reactor was also discussed in the article. The prepared reactor was also utilized to treat polluted water from dyeing and printing process. After continuous treatment for 0.5h, chemical oxygen demand biochemical oxygen demand, quantity of bacteria and ammonia nitrogen of the polluted water were reduced by 93.9%, 87.6%, 99.9% and 67.5%, respectively, which indicated that the method used here could be used for effective organic dyes degradation.

Catalysis↗

Electrochemical degradation of bromopyrogallol red in presence of cobalt ions.

This paper summarizes the results of a degradation test of bromopyrogallol red (BPR) and textile dye wastewater (TDW) with a conventional three-electrode potentiostatic system in the presence of cobalt ions (electro Co(2+)-H2O2 system). H2O2, produced by the two-electron reduction of O2 at the cathode, would react with Co2+ ions, leading to the generation of hydroxyl radicals (*OH), which caused the degradation of the organic pollutants. With BPR degradation process as the reference point, the optimal conditions (pH=4.0 and the concentration of Co2+ is 0.1 mM) and the treating capacity of the system were both studied and compared with electro-Fenton's reagent. Many benefits were shown by the electro Co(2+)-H2O2 system, such as less metal ions consumption, more moderate conditions and faster reaction process. Treated with the system for 0.5 h, chemical oxygen demand and biological oxygen demand of TDW (pH=5.2), without pH adjustment, were reduced by 95.7% and 92.7%, respectively. These characteristics make the method another appropriate solution for wastewater treatment, especially for those contaminated by organic pollutants.

Cobalt↗

Study of carbon nanotubes-HRP modified electrode and its application for novel on-line biosensors.

In this paper, multi-walled carbon nanotubes (MWCNTs) were successfully immobilized on the surface of a glassy carbon electrode by mixing with horse-radish peroxidase (HRP). The electrochemical behavior of H2O2 was also studied with the MWCNTs-HRP modified electrode as a working electrode. The MWCNTs-HRP modified electrode showed excellent response of reduction current for the determination of H2O2 at the potential of -300 mV (vs. Ag/AgCl). We assembled the MWCNTs-HRP modified electrode in a thin-layer flow cell and the H2O2 solution was continuously introduced into the cell with a syringe pump. We optimized the sensitivity of the H2O2 sensor by adjusting the working potential and the pH of the buffer solution. The peak current increased linearly with the concentration of H2O2 in the range 3.0 x 10(-7) to approximately 2.0 x 10(-4) mol L(-1). The detection limit is 1.0 x 10(-7) mol L(-1) (S/N = 3). The interferences from ascorbic acid, uric acid and other electroactive substances can be greatly excluded since the sensor can be operated at -300 mV. Stability and reproducibility of the MWCNTs-HRP chemically modified electrode were also studied in this paper. Fabricated with glucose and lactate oxidase, the MWCNTs-HRP electrode was also applied to prepare the on-line glucose and lactate biosensors because of the high sensitivity for the determination of H2O2.

Biosensing Techniques↗

Study on the effect of electromagnetic impulse on neurotransmitter metabolism in nerve cells by high-performance liquid chromatography-electrochemical detection coupled with microdialysis.

In this paper, a reverse-phase high-performance liquid chromatographic method using a chemically modified electrode coupled with microdialysis was developed to study the effect of electromagnetic impulse (EMI) on monoamine neurotransmitter metabolism in nerve cells. To detect the monoamines and their metabolites, a poly (para-aminobenzoic acid) (P-pABA)-modified electrode was prepared. The modified electrode exhibited efficiently electrocatalytic oxidation for monoamines and their metabolites with relatively high sensitivity, stability, and long life. Nerve cells were primarily cultured. EMI was radiated to three experimental model nerve cells: (i) on mature nerve cells, (ii) on the culture medium, and (iii) on juvenile nerve cells for various periods of time. Then the levels of monoamines in the culture medium were detected by high-performance liquid chromatography-electrochemical detection. The data indicated that electromagnetic fields could influence neurotransmitter metabolism by direct effect on nerve cells or effect on the nutrient medium and that the effect was not only relevant with the length of radiation time, but also with the growing state of the nerve cells.

4-Aminobenzoic Acid↗