PubMed Health⌕ Search

Biomedical subjects

Litong Jin

Publications and source records attributed to Litong Jin.

21 records · Page 2Linked to original sources

Amperometric determination of glutathione and cysteine on a Pd-IrO(2) modified electrode with high performance liquid chromatography in rat brain microdialysate.

A Pd/IrO(2) co-electrodeposited glassy carbon electrode was prepared and the electrochemical behavior of glutathione (GSH) at this chemically modified electrode (CME) has been studied by cyclic voltammetry (CV). The results indicated that the modified electrode efficiently exhibited electrocatalytic oxidation for GSH with relatively high sensitivity, stability, and long-life. Coupled with high-performance liquid chromatography (HPLC), the Pd/IrO(2) modified electrode was utilized for the electrochemical detection (ECD) of the thiocompounds, glutathione and cysteine (Cys). The peak currents were linear with the substance concentrations in the range of 1.0 x 10(-5) mol L(-1) to 8.0 x 10(-4) mol L(-1) for GSH and 4.0 x 10(-6) mol L(-1) to 2.0 x 10(-4) mol L(-1) for Cys. The detection limits were 2.0 x 10(-6) mol L(-1) for GSH and 5.0 x 10(-7) mol L(-1) for Cys with S/N of 3. The method has been successfully applied to assess the contents of GSH and Cys in rat brain microdialysates.

Animals↗

The study of nafion/xanthine oxidase/au colloid chemically modified biosensor and its application in the determination of hypoxanthine in myocardial cells in vivo.

A novel hypoxanthine (Hx) microsensor was constructed. In this work, Nafion xanthine oxidase (XOD) and Au colloid were immobilized onto the surface of a Pt microelectrode. The enzyme biosensor displayed a quick and sensitive response to Hx. Under physiological conditions, a low detection limit, with high selectivity and sensitivity for Hx determination were obtained. The oxidation current [investigated using current-time (I-t) plots] was linear with Hx concentration ranging from 2.0 x 10(-7) to 2.0 x 10(-5) mol L(-1) with a calculated detection limit of 1.0 x 10(-7) mol L(-1) (S/N of 3). The biosensor should be promising for in vivo measurement of Hx without interferences and fouling. The change of Hx concentration in cardiac myocytes stimulated by L-arginine (L-Arg) and acetylcholine (Ach) was also studied.

Biosensing Techniques↗

Determination of drug-protein interactions by microdialysis coupled with liquid chromatography and electrochemical detection based on a nickel hexacyanoferrate modified electrode.

Microdialysis sampling coupled with liquid chromatography-electrochemical detection (LC-ED) was developed and applied to determine the interaction of thiopurine (TP) with bovine serum albumin (BSA). A nickel hexacyanoferrate (NiHCNFe) modified electrode was fabricated and used as the working electrode in LC-ED for the determination of TP. Cyclic voltammetric experiments demonstrate that this chemically modified electrode (CME) can effectively catalyze the electrooxidation of TP. The mechanism of the catalytic oxidation of TP at the CME involves an 'EC' process. In the LC-ED, the CME also shows good stability and reproducibility for the determination of TP. The limit of detection is 5.0 x 10(-7) mol l(-1) for 6-TP with a signal-to-noise ratio of 3. The utility of microdialysis as a quantitative sampling technique for in vitro studies of drug-protein interactions was studied. The microdialysis experiments were performed in phosphate buffer solution (pH 7.4) containing different molar ratios of the drug and protein at 37 degrees C. The collected microdialysis sample with unbound TP was analyzed at the NiHCNFe CME in the LC-ED. The relative recovery of TP determined in vitro is 18.3% at a perfusion rate of 1.0 microl min(-1) and the RSD is about 2.1%. The association constant and the number of binding sites on a BSA molecule calculated with the Scatchard equation are 3.72 x 10(-3) (1 mol(-1)) and 1.51, respectively. This method provides a fast, sensitive and simple technique for the study of drug-protein interactions.

Allopurinol↗