Non-invasive in vivo infrared laser spectroscopy to analyse endogenous oxy-haemoglobin, deoxy-haemoglobin, and blood volume in the rat CNS.

Oxy-haemoglobin (HbO2) and deoxy-haemoglobin (Hb) are chromophores present in biological tissues. Near infrared spectroscopy (NIRS) is a non-invasive methodology based on the low extinction coefficient of tissue in the near infrared region. NIRS can be used to measure changes in the concentration of these chromophores, i.e., haemoglobin, in muscular tissue. In the present work, NIRS has been used for the non-invasive monitoring of HbO2, Hb, and blood volume (V: representing total haemoglobin, i.e., HbO2+Hb) in vivo in the whole rat brain. This has been performed by means of prototype instrumentation based on optic fibre probes placed in contact with the head of anaesthetised rats held in a stereotaxic frame. A preliminary test of the instrument has been performed on human muscle, i.e., lateral gastrocnemius, in order to evaluate the ability of the instrument to detect oxygenation changes. Afterwards, the effects of pharmacological treatments, such as systemic amphetamine and nicotine treatments on the CNS have been detected.

Amphetamine↗

New optical scheme for a polarimetric-based glucose sensor.

A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Aqueous Humor↗

Autofluorescence methods in ophthalmology.

An overview of the fluorophores of the eye, the methods used to measure ocular fluorescence, and the existing or ready-to-market instrumentation for the early diagnosis and monitoring of ophthalmic pathologies is presented. Emphasis is given to the impact that a more detailed knowledge of the fluorophores of the eye, their age and pathology relationship, and the considerable technology-driven progress in optical devices and components has had on the development of new compact yet powerful instruments for population screening and for patient follow-ups, using fluorometry alone or in combination with other optical techniques such as light scattering.