PubMed Health⌕ Search

PubMed · 14715061

New optical scheme for a polarimetric-based glucose sensor.

Abstract

A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rafat R Ansari, Stefan Böckle, Luigi Rovati. New optical scheme for a polarimetric-based glucose sensor.. https://doi.org/10.1117/1.1626664

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intraluminal pressure response in Baerveldt tube shunts: a comparison of modification techniques.

PURPOSE: To design an apparatus for in vitro quantification of effects of modifications to nonvalved tube shunts, and to compare the effects of these modifications done to prevent early postoperative hypotony. MATERIALS AND METHODS: A testing apparatus was designed and constructed to measure intraluminal pressure (ILP) during constant infusion of balanced salt solution at 2 microL/min through Baerveldt tube shunts mounted on cadaver eyes. Three different modifications were performed and 3 shunts were used for each modification. The modifications were partial tube occlusion with a 3-0 Supramid suture, tube perforation with a 27-gauge needle on an occluded tube, and a 1.2 mm longitudinal venting slit on an occluded tube. RESULTS: The final steady state ILP for the 3-0 Supramid partially occluded tube ranged between 1.6 and 2.8 mm Hg over 3 trials with an average final steady state ILP of 2.0 mm Hg. The 27-gauge needle perforation produced ILPs of 4.6 to 8.2 mm Hg over 3 trials with an average final steady state pressure of 5.9 mm Hg. The 1.2 mm longitudinal venting slit produced an ILP range of 12.6 to 17.3 mm Hg over 3 trials with an average final steady state ILP of 14.8 mm Hg. The differences in final steady state ILP between the 3 modification techniques were statistically significant (P=0.00036). CONCLUSIONS: The 3-0 Supramid occlusion and the 27-gauge perforation techniques produced hypotony, whereas the 1.2 mm longitudinal venting slit produced acceptable pressures in vitro.

Aqueous Humor↗

Myocilin-associated exosomes in human ocular samples.

Mutations in myocilin result in ocular hypertension, likely due to decreased drainage of aqueous humor through the trabecular meshwork. Since less myocilin is found in the aqueous humor of those with disease-causing mutations, understanding myocilin's role in the aqueous humor is of clinical importance. Recently, myocilin was shown to exit cultured trabecular meshwork cells in association with shed vesicles called exosomes. To examine relevance of this finding in a physiological setting, the present study examined three different types of ocular samples for the presence of myocilin-associated exosomes. Using differential centrifugation steps, we found myocilin associated with exosomes isolated from effluent collected from human anterior segments in organ culture and aqueous humor obtained from human cadaveric eyes or from patients undergoing excisional surgery. Similar to results with cultured cells, myocilin associated predominately with exosomes in fresh samples, appeared mostly soluble at later times, and had biochemical properties (density of 1.13-1.19 g/ml in linear sucrose gradient) similar to those characteristics of exosomes. These data indicate that exosomes are present and may facilitate the transport of myocilin into the extracellular space of human ocular cells.

Aqueous Humor↗