PubMed Health⌕ Search

Biomedical subjects

M A Cabrerizo-Vílchez

Publications and source records attributed to M A Cabrerizo-Vílchez.

5 recordsLinked to original sources

Surface characterization of human serum albumin and sodium perfluorooctanoate mixed solutions by pendant drop tensiometry and circular dichroism.

The interfacial behavior of mixed human serum albumin (HSA)/sodium perfluorooctanoate (C8FONa) solutions is examined by using two experimental techniques, pendant drop tensiometry and circular dichroism spectroscopy. Through the analysis of the surface tension of the mixed solutions, surface competitive adsorption at the air-water interface between C8FONa and HSA is detected. The dynamic adsorption curves exhibit the distinct regimes in their time-dependent surface tension. The nature of these regimes is further analyzed in terms of the variation of the molecules surface areas. As a consequence, a compact and dense structure was formed where protein molecules were interconnected and overlapped. Thus, a reduction of the area occupied per molecule from 100 to 0.2 nm(2) is interpreted as a gel-like structure at the surface. The presence of the surfactant seems to favor the formation of this interfacial structure. Finally, measurements of circular dichroism suggests a compaction of the protein due to the association with the surfactant given by an increase of alpha-helix structure in the complexes as compared to that of pure protein.

Adsorption↗

Streaming current, permeability, and microelectrophoresis of polystyrene latices in methanol-ethanol mixtures.

The influence of the solvent (methanol-ethanol mixtures) on the electrokinetic behavior of polystyrene latices with sulfate groups was studied (methanol content was increased by 0.2 at a constant KBr concentration of 1 mM). Viscosity, density, and dielectric constant (eta, rho, and epsilon) were determined at experimental conditions. Two latices (with different surface charge densities and sizes) were used. Electrophoresis measurements were used for dilute dispersions. Streaming current and hydrodynamic permeability were measured for porous plugs. Linear trends in the electrokinetic measurements were observed in the whole molar fraction range. The experimental data obtained from different techniques allow determining the zeta potential according to a well-established classical relationship. The results obtained were analyzed on the basis of the solvent mixture properties and the electrical interface behavior. In addition, permeability data provided valuable information to interpret effects at the solid-liquid interface of the porous plug.

Journal Article↗

Development of a constant surface pressure penetration langmuir balance based on axisymmetric drop shape analysis.

A new constant pressure pendant-drop penetration surface balance has been developed combining a pendant-drop surface balance, a rapid-subphase-exchange technique, and a fuzzy logic control algorithm. Beside the determination of insoluble monolayer compression-expansion isotherms, it allows performance of noninvasive kinetic studies of the adsorption of surfactants added to the new subphase onto the free surface and of the adsorption/penetration/reaction of the former onto/into/with surface layers, respectively. The interfacial pressure pi is a fundamental parameter in these studies: by working at constant pi one controls the height of the energy barrier to adsorption/penetration and can select different regimes and steps of the adsorption/penetration process. In our device a solution drop is formed at the tip of a coaxial double capillary, connected to a double microinjector. Drop profiles are extracted from digital drop micrographs and fitted to the equation of capillarity, yielding pi, the drop volume V, and the interfacial area A. pi is varied changing V (and hence A) with the microinjector. Control is based on a case-adaptable modulated fuzzy-logic PID algorithm able to maintain constant pi (or A) under a wide range of experimental conditions. The drop subphase liquid can be exchanged quantitatively by the coaxial capillaries. The adsorption/penetration/reaction kinetics at constant pi are then studied monitoring A(t), i.e., determining the relative area change necessary at each instant to compensate the pressure variation due to the interaction of the surfactant in the subsurface with the surface layer. A fully Windows-integrated program manages the whole setup. Examples of experimental protein adsorption and monolayer penetration kinetics are presented.

Journal Article↗

Dentin wetting by four adhesive systems.

OBJECTIVES: To evaluate the dentin wetting by four adhesive systems and to relate the wetting properties with the adhesive efficiency. METHODS: Scotch Bond Multipurpose Plus (3M), Syntac Single-Component (Vivadent), One-Step (Bisco) and Heliobond (Vivadent) were used. The substrate was superficial and deep human dentin. Roughness and water contact angle were measured before and after acid etching. Dentin wetting by resins was studied by contact angle measurements as a function of time to evaluate the spreading time. The shear bond strength was evaluated following a single plane method, and the microleakage was evaluated in Class V cavities. RESULTS: Acid etching increased dentin roughness and wettability and no differences were found between acids tested. Dentin wetting and roughness was higher on deep dentin. Dentin wetting and shear bond strength of resins was similar except for Heliobond that displayed the lowest value. Microleakage was higher on the gingival wall, and the leaking was lowest for Scotch Bond Multipurpose Plus, and maximum for Heliobond. The spreading time exceeded 30s with water-based and hydrophobic adhesives, and was lower with an acetone-based adhesive. Dentin depth had some influence on contact angle and shear bond strength: contact angles obtained with SBMP and One-Step were higher on superficial dentin, and shear bond strength for One-Step was higher on superficial dentin. Dentin wetting by resins could be correlated to shear bond strength and microleakage. SIGNIFICANCE: Dentin acid etching with different conditioners promotes similar roughness and wetting changes. On a similar substrate, the adhesion depends on the chemical and wetting characteristics of resins.

Acid Etching, Dental↗

Influence of enamel prophylaxis on wettability of three commercially available orthophosphoric acids.

An in vitro study was performed to assess the wettability of orthophosphoric acid after different procedures for cleaning the enamel surface. Ninety noncarious third molars were randomly distributed into three groups with different enamel surface treatments: an air-powder polisher unit, prophylaxis pastes, and no enamel surface cleaning. Three commercially available orthophosphoric acids were used, and there were 10 teeth in each group. Acid viscosity values and contact-angle measurements were obtained. Each enamel surface was also examined with the scanning electron microscope. Results suggested that the surface treatment with which the best spreading of the acid solution was attained was the air-powder polisher. The least spreading of the acid was obtained with prophylaxis pastes, in which contact angles were even higher than those obtained on the untreated enamel surface. The 3M acid solution was the one that showed the best spreading onto the enamel surface.

Acid Etching, Dental↗