PubMed Health⌕ Search

Biomedical subjects

M A Hassaballa

Publications and source records attributed to M A Hassaballa.

3 recordsLinked to original sources

Observed kneeling ability after total, unicompartmental and patellofemoral knee arthroplasty: perception versus reality.

Kneeling is an important function of the knee, but little information is available on ability to kneel after different knee arthroplasty procedures. Previous work has asked patients about their kneeling ability; in this study it was objectively assessed. One hundred and twenty two patients - 38 having had total knee replacement (TKR), 53 unicompartmental knee replacement (UKR), 31 patello-femoral replacement (PFR) - were observed trying to kneel at 90 degrees on a chair, at 90 degrees on the floor, and at 120 degrees on the floor. Only 37% of patients thought they could kneel, whereas 81% were actually able to kneel ( p<0.001). Ability to kneel on the chair and on the floor at 90 degrees was significantly better than perceived ability for all prosthesis types ( p<0.001). Kneeling at 120 degrees showed no difference between perception and reality except for the PFR group ( p<0.05). In all positions, increased range of movement significantly improved kneeling ability ( p<0.001). Kneeling ability in men was significantly better than in women ( p<0.001). Patient-centred questionnaires do not accurately document kneeling ability after knee arthroplasty.

Adult↗

Can knees kneel? Kneeling ability after total, unicompartmental and patellofemoral knee arthroplasty.

This study investigates patients' perception of kneeling ability before and at 1 and 2 years after total, unicompartmental knee replacement (UKR) and patellofemoral knee replacement (PFR), for osteoarthritis. Kneeling is an important function of the knee joint required for many daily activities and inability to kneel after knee surgery is a frequent cause of dissatisfaction. Data were prospectively collected on 253 knees. A kneeling score was obtained by analysis of the relevant section of the Oxford knee score. Scores were obtained pre-operatively and at 1 and 2 years post-operatively. Absolute values and change following surgery were recorded. Correlations with pain and other knee functions were also made. Kneeling ability prior to surgery was poor in all 3 groups (80% found it extremely difficult or impossible to kneel) and improved in all groups after surgery (20% had little or no difficulty to kneel at 2 years). Kneeling ability was best in UKR and worst in PFR. These results suggest that kneeling ability in osteoarthritic patients is poor but improves with knee arthroplasty surgery, however the majority of patients will still have difficulty in kneeling.

Aged↗

Button versus buttonless castings for removable partial denture frameworks.

Casting removable partial dentures (RPDs) without completely filling the sprue channels and generating casting buttons would result in saving metal and making more defect-free castings. This investigation tested whether a complete and sound RPD casting can be obtained when a minimal amount of metal is used. A factorial experimental design, three spruing methods, two metal feeding directions, and two different weights of metal were used to cast 60 Kennedy class II, modification 1 RPDs. The metal used to cast each framework was either enough to result in a full button or in no button. Visual and radiographic examinations and counting of defects were made by two independent operators who were unaware of the spruing method, feeding direction, or amount of metal used to make the framework. The completeness of the casting and the presence of porosities were evaluated for clasps, major connectors, and meshworks. The use of minimal metal to cast RPDs was equally as successful as using enough for a full button, provided that the appropriate spruing arrangement and metal feeding direction were chosen. Indirect metal feeding for maxillary RPDs was successful with the proper spruing arrangement.

Chromium Alloys↗