Button versus buttonless castings for removable partial denture frameworks.

Abstract

Casting removable partial dentures (RPDs) without completely filling the sprue channels and generating casting buttons would result in saving metal and making more defect-free castings. This investigation tested whether a complete and sound RPD casting can be obtained when a minimal amount of metal is used. A factorial experimental design, three spruing methods, two metal feeding directions, and two different weights of metal were used to cast 60 Kennedy class II, modification 1 RPDs. The metal used to cast each framework was either enough to result in a full button or in no button. Visual and radiographic examinations and counting of defects were made by two independent operators who were unaware of the spruing method, feeding direction, or amount of metal used to make the framework. The completeness of the casting and the presence of porosities were evaluated for clasps, major connectors, and meshworks. The use of minimal metal to cast RPDs was equally as successful as using enough for a full button, provided that the appropriate spruing arrangement and metal feeding direction were chosen. Indirect metal feeding for maxillary RPDs was successful with the proper spruing arrangement.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Mohammed, M A Hassaballa, Y F Talic. 1994. Button versus buttonless castings for removable partial denture frameworks.. https://doi.org/10.1016/0022-3913(94)90566-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of a cast flexible plate as a hinge substitute in a hinge-lock design removable partial denture framework.

PURPOSE: The use of a hinge for a removable partial denture with an opening labial bow was replaced by the design and construction of a flexible plate incorporated as part of a cobalt-chromium casting. METHODS: Three similar prostheses were constructed and tested in vitro on an endurance test machine. Each test piece completed 12,000 opening and closing operations without fracture, which a previous study showed is a probable life cycle of a typical removable partial denture with a hinged section. RESULTS: This plate provided sufficient flexibility to allow functional operation of the removable partial denture by a patient.

Chromium Alloys

[Effect of surface hardness of the femur head prosthesis on abrasive wear forces in pairing with polyethylene for artificial hip joints].

The problem of wear has become a major issue in total joint replacement. A correlation between biomaterial hardness and abrasive wear mechanisms may be assumed. To investigate the effect of hardness, cobalt-chromium (CoCr) femoral heads coated with hard amorphous-hydrogenated carbon (a-CH) were tested against uncoated heads under conditions of abrasive wear. The heads were paired with polyethylene (UHMWPE) discs in a ball-on-disc machine. The abrasive wear resistance of the heads increased with surface hardness, and qualitatively differing patterns of wear were observed on the UHMWPE surfaces, depending on the abrasive wear of the matching areas of the heads. Accordingly, when evaluating biomaterials for their suitability for use in total joint replacement, hardness should be considered one of the relevant factors among the material properties with an influence on wear.

Chromium Alloys

Dye penetration at a cobalt-chromium alloy--composite resin interface.

This study examined microleakage along the interface of resin systems bonded to cobalt-chromium alloy; a microfine resin with adhesive properties based upon methacrylic acid, and a hybrid resin containing an adhesive phosphate monomer. Specimens were thermocycled between 4 degrees, 37 degrees and 60 degrees C over 1000-10,000 cycles and placed in 0.1% neutral red dye for 7 days. Each was cut diagonally and the interfaces photographed using an optical microscope. Dye penetration was expressed as a percentage of the total length of each edge. The hybrid resin showed significantly less microleakage than the microfine resin.

Chromium Alloys