PubMed Health⌕ Search

Biomedical subjects

M A Shoffner

Publications and source records attributed to M A Shoffner.

7 recordsLinked to original sources

Integrated cell isolation and polymerase chain reaction analysis using silicon microfilter chambers.

White blood cells are isolated from whole blood in silicon-glass 4.5-microliter microchips containing a series of 3.5-micron feature-sized 'weir-type' filters, formed by an etched silicon dam spanning the flow chamber. Genomic DNA targets, e.g., dystrophin gene, can be directly amplified using the polymerase chain reaction (PCR) from the white cells isolated on the filters. This dual function microchip provides a means to simplify nucleic acid analyses by integrating in a single device two key steps in the analytical procedure, namely, cell isolation and PCR.

Cell Separation↗

Diagnosis of Duchenne/Becker muscular dystrophy and quantitative identification of carrier status by use of entangled solution capillary electrophoresis.

Use of capillary electrophoresis, a new and useful analytical tool, offers a variety of advantages for nucleic acid analyses, including rapid analysis, automation, high resolution, qualitative and quantitative results, and low consumption of both sample and reagents. We report the first example of the use of entangled solution capillary electrophoresis (ESCE) and laser-induced fluorescence detection (LIF) for separation-based diagnostics in the quantitative analysis of multiplex PCR products for determination of carrier status of Duchenne/ Becker muscular dystrophy (DMD/BMD). This approach greatly improved the speed, resolution, and sensitivity of information needed for the diagnosis of DMD/BMD compared with that from conventional diagnostic methods, and is of general utility for diagnosis of genetic diseases.

Electrophoresis, Capillary↗

Analysis of ligase chain reaction products amplified in a silicon-glass chip using capillary electrophoresis.

Ligase chain reaction (LCR) is a useful molecular technique for detecting known point mutations. We report the first example of the use of a disposable silicon-glass micro-chip for LCR and the first application of capillary electrophoresis (CE) to analyze samples amplified by LCR in a chip. Silicon-glass chips were manufactured using conventional photolithography and anodic bonding. The chips provide three distinct advantages for LCR: excellent thermal conductivity, a micro reaction volume ( < 10 microliters), and reproducible, low-cost manufacturing. Investigation and quantitation of amplification efficiency of LCR in a chip or in a tube requires an analytical technique that is faster and more convenient than the conventional slab gel methods. Slab gel electrophoresis uses relatively large amounts of sample and is labor-intensive and time-consuming, and thus is unsuitable for the separation and detection of LCR products. In contrast CE requires sample volume (original LCR products) of less than 1 microliter and is therefore well-suited to analysis of the micro-volume reaction mixture from chips. We combined CE with a sensitive laser induced fluorescence (LIF) detection system for the rapid separation and quantitative detection of LCR products amplified from the lacI gene in a silicon-glass chip. Comparative studies were made with LCR between tubes and silicon-glass chips. CE-LIF analysis is ideally suited to examination of micro-LCR amplification with high throughput. The technologies may find medical uses in disease diagnosis and research.

Base Sequence↗

Chip PCR. I. Surface passivation of microfabricated silicon-glass chips for PCR.

The microreaction volumes of PCR chips (a microfabricated silicon chip bonded to a piece of flat glass to form a PCR reaction chamber) create a relatively high surface to volume ratio that increases the significance of the surface chemistry in the polymerase chain reaction (PCR). We investigated several surface passivations in an attempt to identify 'PCR friendly' surfaces and used those surfaces to obtain amplifications comparable with those obtained in conventional PCR amplification systems using polyethylene tubes. Surface passivations by a silanization procedure followed by a coating of a selected protein or polynucleotide and the deposition of a nitride or oxide layer onto the silicon surface were investigated. Native silicon was found to be an inhibitor of PCR and amplification in an untreated PCR chip (i.e. native slicon) had a high failure rate. A silicon nitride (Si(3)N(4) reaction surface also resulted in consistent inhibition of PCR. Passivating the PCR chip using a silanizing agent followed by a polymer treatment resulted in good amplification. However, amplification yields were inconsistent and were not always comparable with PCR in a conventional tube. An oxidized silicon (SiO(2) surface gave consistent amplifications comparable with reactions performed in a conventional PCR tube.

Base Sequence↗

Chip PCR. II. Investigation of different PCR amplification systems in microbabricated silicon-glass chips.

We examined PCR in silicon dioxide-coated silicon-glass chips (12 microl in volume with a surface to volume ratio of approximately 17.5 mm(2)/microl) using two PCR reagent systems: (i) the conventional reagent system using Taq DNA polymerase; (ii) the hot-start reagent system based on a mixture of TaqStart antibody and Taq DNA polymerase. Quantitative results obtained from capillary electrophoresis for the expected amplification products showed that amplification in microchips was reproducible (between batch coefficient of variation 7.71%) and provided excellent yields. We also used the chip for PCR directly from isolated intact human lymphocytes. The amplification results were comparable with those obtained using extracted human genomic DNA. This investigation is fundamental to the integration of sample preparation, polynucleotide amplification and amplicate detection on a microchip.

Antibodies↗

Application of backpropagation neural networks to diagnosis of breast and ovarian cancer.

Neural network programs have been developed in an attempt to improve the diagnosis of breast and ovarian cancer using a group of laboratory tests and the age of the patient. The laboratory tests employed in this study include albumin, cholesterol, HDL-cholesterol, triglyceride, apolipoproteins A1 and B, NMR linewidth (the Fossel Index) and a tumor marker (i.e., CA 15-3 or CA 125). The breast cancer study involved 104 patients (45 malignant and 59 benign subjects). The ovarian cancer study involved 98 individuals (35 malignant, 36 benign and 27 control subjects). Methods are outlined for identification of the most influential input parameters and optimization of network structure and training. Network characteristics were contrasted with the test results of the appropriate serum tumor marker assay. For the breast cancer study, the best neural network program, using six input parameters, had a sensitivity of only 55.6% and a specificity of 72.9%. The tumor marker CA 15-3 alone gave results of 61.3% and 64.4%, respectively. For the ovarian cancer study, the best neural network program, using six input parameters, had a sensitivity of 80.6% and a specificity of 85.5%. The tumor marker CA 125 alone gave results of 77.8% and 82.3%, respectively. These methods provide an objective approach to neural network optimization and parameter selection applicable to other data bases of clinical and laboratory data.

Biomarkers, Tumor↗

PCR in a silicon microstructure.

Devices for performing polymerase chain reactions (PCR) have been developed for use with photolithographed silicon. Microchambers capable of holding between 5.0 and 10 microL of PCR reagents were constructed by etching specific areas of rectangular silicon chips (17 x 15 mm), which were then capped with Pyrex glass. These silicon devices (PCRChips), which were etched to depths of 40-80 microns, permitted free flow of fluids in the microchannels and microchambers. Access to the microchambers was through holes in the silicon. Thermal cycling of the PCR reagents was achieved by placing the disposable PCRChip in a small holder containing a computer-controlled Peltier heater-cooler. Successful amplification was demonstrated by electrophoresis of products in agarose gel containing ethidium bromide, and the migration of the product was compared with that obtained in a commercially available thermal cycler. The thermal characteristics of the silicon, coupled with the high surface area to volume ratio in the new devices, are particularly advantageous features for amplification by PCR.

Bacteriophage lambda↗