Septal lead implantation for the reduction of paced QRS duration using passive-fixation leads.

In 120 consecutive patients with standard pacing indications, we tested the feasibility of RV septal lead implantation technique guided by surface ECG and the degree to which this technique reduces paced QRS duration compared to RV apical stimulation when passive-fixation leads are used. During implantation, an ECG was recorded with a paper speed of 100 mm/s using the orthogonal Frank leads, and QRS was measured from the earliest to the latest deflection in any of the Frank leads. Pace-mapping of the septum was performed until QRS was minimal. The lead was attached, where QRS, pacing threshold, lead impedance, and EGM amplitude provided the best compromise. An average of 3.7 +/- 2.5 attempts (range 1-18, median 7) was needed until a final implantation site was found. There were no technical problems during implantation. QRS could be reduced by 5-55 ms (mean delta QRS 19 +/- 11 ms) in 83 (69%) of 120 patients. In 22 (18%) patients, QRS was identical with apical and septal pacing, and in 15 (13%) patients, QRS was 5-20 ms (10 +/- 4) longer despite septal stimulation. Average QRS was significantly shorter during septal pacing compared with apical pacing (151 +/- 20 vs 162 +/- 23 ms, P < 0.001). There was a tendency towards greatest QRS reduction when the high septum was stimulated (22 +/- 11 ms reduction) as compared with mid- (18 +/- 11 ms) or apical parts of the RV septum (16 +/- 10 ms). QRS reduction was most likely if apical QRS width was > 170 ms (P = 0.0002), and there was an inverse correlation between apical QRS and delta QRS (r = 0.53, P < 10(-7)). During a mean follow-up of 14 months, there was no pacing or sensing problem and no lead dislodgment occurred.

Aged↗

Longevity of dual chamber pacemakers: device and patient related determinants.

In 382 patients with three different dual chamber pulse generators, the median time interval to battery depletion was 98.3 months. Cox regression analysis revealed the following variables as significant predictors of battery longevity: programmed pacing rate, energy of the stimulation output, mode of stimulation (i.e., proportion of paced cycles in one or two chambers), battery capacity, and internal sensing current of the pacemaker. Although 27% of all patients died before the service life of the pacemaker was over and despite a rate of premature reoperations of 8.6%, the majority of pacemaker patients (55%) fully used the expected battery life span of the pulse generator. Patients who died before the pacemaker had reached its end of service were significantly older at implantation than patients who survived until pacemaker replacement. The vast majority (92%) of patients received another dual chamber pulse generator when replacement was required. These data underline the need for long-lasting dual chamber devices.

Aged↗

Do battery depletion indicators reliably predict the need for pulse generator replacement?

The aim of this study was to test the validity of battery depletion indicators to forecast end of service (EOS) in dual chamber pulse generators (PG). Two additional approaches for prediction of EOS were evaluated as well: the real-time telemetry of cell impedance and a battery stress test (BST) that used a transitory increase in pacing rate. The study population consisted of 119 patients with Intermedics dual chamber PG models Cosmos II and Relay, in which cell impedance had exceeded 2.5 k omega. The patients were followed in 6-month intervals. If the interrogation of the PG or the BST prompted the appearance of the intensified follow-up indicator (IFI), the next follow-up was scheduled within 2 months. PG replacement was performed on physician's discretion or immediately on appearance of the elective replacement indicator (ERI), regardless of the method of ERI provocation. During a period of 2 years/and 9 months, 33 patients underwent PG replacement. Out of 21 patients with positive ERI indicators, only 5 had positive warning indicators of approaching battery depletion in the preceding follow-up (IFI during BST, n = 4; ERI during BST n = 1). The majority of patients (n = 16, 76%) revealed ERI without prior activation of IFI, neither spontaneous nor during the BST. Four of these 16 ERI-positive patients had cell impedance values far below the ERI limits of the manufacturer. Based on battery depletion indicators, an exact prediction of EOS of dual chamber pacemakers is not possible. Measuring battery impedance allows for a statistical estimation of remaining service life but it may be misleading in the individual case. A BST that is based on a temporary increase of pacing rate is invalid in forecasting battery depletion. As activation of the ERI can trigger an abrupt change to the VVI backup mode, pacemaker dependent patients with low programmed basic pacing rates may be hemodynamically compromised by an unexpected activation of ERI. Close monitoring intervals and PG replacement before appearance of the ERI is recommended in those patients.

Electric Impedance↗

AAIR versus DDDR pacing in the bradycardia tachycardia syndrome: a prospective, randomized, double-blind, crossover trial.

In 19 patients paced and medicated for bradycardia tachycardia syndrome (BTS), AAIR and DDDR pacing were compared with regard to quality of life (QoL), atrial tachyarrhythmia (AFib), exercise tolerance, and left ventricular (LV)function. Patients had a PQ interval < or = 240 ms during sinus rhythm, no second or third degree AV block, no bundle branch block, or bifascicular block. In DDDR mode, AV delay was optimized using the aortic time velocity integral. After 3 months, QoL was assessed by questionnaires, patients were investigated by 24-hour Holter, cardiopulmonary exercise testing (CPX) was performed, and LV function was determined by echocardiography. QoL was similar in all dimensions, except dizziness, showing a significantly lower prevalence in AAIR mode. The incidence of AFib was 12 episodes in 2 patients with AAIR versus 22 episodes in 7 patients with DDDR pacing (P = 0.072). In AAIR mode, 164 events of second and third degree AV block were detected in 7 patients (37%) with pauses between 1 and 4 seconds. During CPX, exercise duration and work load were higher in AAIR than in DDDR mode (423+/-127 vs 402+/-102 s and 103+/-31 vs 96+/-27 Watt, P < 0.05). Oxygen consumption (VO2), was similar in both modes. During echocardiography, only deceleration of early diastolic flow velocity and early diastolic closure rate of the anterior mitral valve leaflet were higher in DDD than in AAI pacing (5.16+/-1.35 vs 3.56+/-0.95 m/s2 and 69.2+/-23 vs 54.1+/-26 mm/s, P < 0.05). As preferred pacing mode, 11 patients chose DDDR, 8 patients chose AAIR. Hence, AAIR and DDDR pacing seem to be equally effective in BTS patients. In view of a considerable rate of high degree AV block during AAIR pacing, DDDR mode should be preferred for safety reasons.

Aged↗

Swedish midwives' care of women who are at high obstetric risk or who have obstetric complications.

OBJECTIVE: to describe how midwives experience the care of women who are at high obstetric risk or who have an obstetric complication during pregnancy, childbirth and early parenthood. DESIGN: a qualitative approach using a phenomenological method. PARTICIPANTS: 10 Swedish midwives, recognised as highly skilled clinicians with at least five years of clinical experience in the studied context, from four different hospitals. FINDINGS: the essence of midwifery when caring for women at high obstetric risk or with a manifested complication was defined as 'a struggle for the natural process'. Women's transition, physically as well as emotionally, during pregnancy, childbirth and early parenthood, was described as a genuinely natural process. The midwives' struggle consisted of encouraging and preserving this process within each woman. It was based on embodied knowledge and included a balancing between the medical and natural perspectives. Prerequisites, and therefore part of the struggle for the natural process, were sensitivity to the spontaneous, mutual interaction with the woman and enduring presence. KEY CONCLUSIONS AND IMPLICATION FOR PRACTICE: the midwives' responsibility is to promote the natural process during pregnancy, childbirth and puerperium within every woman at high obstetric risk or with obstetric complications. The findings could serve as a basis for reflection on the professional role of midwives, and on the organisation of modern maternity care.

Adaptation, Psychological↗

Evaluation of liquid handling conditions in microplates.

Liquid handling in higher density microplates (e.g., 1536-well microplates) for more efficient drug screening necessitates carefully selected and optimized parameters. The quality of a liquid handling procedure is dependent on the carryover rate of residual liquids during the pipetting process, the mixing behavior in the wells, foam and bubble formation, and evaporation. We compared and optimized these parameters in 96-, 384-, and 1536-well microplates, and herein we critically evaluate the performance of the CyBi-Well 96/384/1536 automated micropipetting device, which formed the basis of our evaluation studies.

Drug Contamination↗

Vasoactive treatment for hearing preservation in acoustic neuroma surgery.

OBJECT: Delayed hearing loss following surgery for acoustic neuroma indicates anatomical and functional preservation of the cochlear nerve and implies that a pathophysiological mechanism is initiated during surgery and continues thereafter. Intraoperative brainstem auditory evoked potentials (BAEPs) typically demonstrate gradual reversible loss of components in these patients. METHODS: Based on this BAEP pattern, a consecutive series of 41 patients with unilateral acoustic neuromas was recruited into a prospective randomized study to investigate hearing outcomes following the natural postoperative course and recuperation after vasoactive medication. Both groups were comparable in patient age, tumor size, and preoperative hearing level. Twenty patients did not receive postoperative medical treatment. In 70% of these patients anacusis was documented and in 30% hearing was preserved. Twenty-one patients were treated with hydroxyethyl starch and nimodipine for an average of 9 days. In 66.6% of these patients hearing was preserved and in 33.3% anacusis occurred. CONCLUSIONS: These results are statistically significant (p < 0.05, chi2 = 5.51) and provide evidence that these surgically treated patients suffer from a disturbed microcirculation that causes delayed hearing loss following removal of acoustic neuromas.

Adult↗

[Psychological profile of patients with COPD: contribution of Semiometry].

Patients with chronic bronchitis often ignore, or pretend to ignore, their disease and generally consult very late. The physician's advice is often quite vague and centered on smoking. One of the objectives of this study was to better understand the psychological profile of patients with chronic bronchitis in order to better apprehend the patient-physician relationship and therapeutic options. Semiometry was designed to overcome the problem encountered by physicians who would like to understand who their patients are without directly asking them. The concept is based on submitting very ordinary words to these subjects and asking them whether they like the word or not. An analysis of their responses allows a very deep understanding of their psychological profile. Briefly, the patient-physician relationship is quite difficult in COPD. The patient "brings" the disease to the physician, "putting" it in his hands and asking him to cure it without having to do anything concerning himself, his life or his behavior. The physician is called on to answer this challenge that can be expressed as "trying to get the patient to play the game without getting caught".

Adaptation, Psychological↗

Phenyl- and butyltin analysis in small biological samples by cold methanolic digestion and GC/MS.

A very efficient technique for the analysis of six butyl- and phenyltin compounds in biota samples has been developed. No special equipment is needed for sample preparation, which is based on cold methanolic digestion with subsequent aqueous ethylation and liquid-liquid extraction. For samples of only 40 mg of biological materials, method detection limits ranging from 4 to 52 ng/g were achieved using gas chromatography/mass spectrometry. Relative recoveries for the individual butyl- and phenyltins, referring to perdeuterated organotin analogues as internal standards, ranged from 96 to 107%. Organotin concentrations in insect larvae (Chironomus riparius) and a reference mussel tissue (CRM 477) were determined with excellent precision (RSD <5%), and the measured butyltins in CRM 477 were in good agreement with the certified values. Comparison with accelerated solvent extraction confirmed high accuracy, and application for a bioconcentration experiment with phenyltins demonstrated the robustness and suitability of the method for routine analyses. The procedure allows fast, reliable, and simple determination of organotin compounds in low-size biological samples, which was demonstrated for bioconcentration experiments.

Gas Chromatography-Mass Spectrometry↗

Use of QRA for decision support in the design of an offshore oil production installation.

QRA is today widely used as a tool for decision support in the offshore industry. Its use has gradually changed from a prescribed analysis for verification purposes to a tool being actively used in an integrated mode. The paper describes its use in the design of a modern offshore platform. The paper addresses work methodology, selection of tools and data, organisation of QRA with other activities. Specific examples are given.

Decision Making↗

Modelling nursing activities: electronic patient records and their discontents.

A fully integrated and operating EPR in a clinical setting is hard to find: most applications can be found in outpatient or general practice settings or in isolated hospital wards. In clinical work practice problems with the electronic patient record (EPR) are frequent. These problems are at least partially due to the models of health care work embedded in EPRs. In this paper we will argue that these problems are at least partially due to the models of health care work embedded in current EPRs. We suggest that these models often contain projections of nurses' and doctors' work as it should be performed on the ward, rather than depicting how work is actually performed. We draw upon sociological insights to elucidate the fluid and pragmatic nature of healthcare work and give recommendations for the development of an empirically based EPR, which can support the work of nurses and other health care providers. We argue that these issues are of great importance to the nursing profession, since the EPR will help define the worksettings of the future. Since it is a tool that will impact the development of the nursing profession, nurses have and should have a stake in its development.

Humans↗

Provocation with stress and electricity of patients with "sensitivity to electricity".

Twenty-four patients with self-reported "sensitivity to electricity" were divided into two groups and tested in a double-blind provocation study. These patients, who reported increased skin symptoms when exposed to electromagnetic fields, were compared with 12 age- and sex-matched controls. Both groups were exposed to 30-minute periods of high or low stress situations, with and without simultaneous exposure to electromagnetic fields from a visual display unit. The matched controls were tested twice and given the same exposure as the patients but had the fields turned on every time. Stress was induced by requiring the participants to act in accordance with a random sequence of flashing lights while simultaneously solving complicated mathematical problems. Blood samples were analyzed for levels of the stress-related hormones melatonin, prolactin, adrenocorticotrophic hormone, neuropeptide Y, and growth hormone, and the expression of different peptides, cellular markers, and cytokines (somatostatin, CD1, factor XIIIa, and tumor necrosis factor-alpha). Skin biopsies were also analyzed for the occurrence of mast cells. Stress provocation resulted in feelings of more intense mental stress and elevated heart rate. The patients reported increased skin symptoms when they knew or believed that the electromagnetic field was turned on. With the blind conditions there were no differences between "on" or "off." Inflammatory mediators and mast cells in the skin were not affected by the stress exposure or by exposure to electromagnetic fields. The main conclusion was that the patients did not react to the fields.

Antibodies↗

The influence of right atrial septal pacing on the interatrial contraction sequence.

UNLABELLED: Right atrial septal pacing yields shorter interatrial conduction delays than conventional right atrial pacing at the free wall or the right atrial appendage. However, the hemodynamic effects of right atrial septal pacing are less well known. This study measured the delay between right and left atrial contractions during right atrial septal pacing (n = 21), conventional right atrial pacing (n = 32) and atrial multisite pacing (n = 6) by pulse Doppler echocardiography of transtricuspidal and transmitral blood flow. The effects of right atrial septal pacing (n = 14) versus conventional right atrial pacing (n = 22) on the optimal AV delay during dual chamber pacing was examined in patients with high degree atrioventricular (AV) block. Compared to sinus rhythm, conventional right atrial pacing increased P wave duration from 119 +/- 21 ms to 137 +/- 24 ms (P < 0.001), whereas both right atrial septal pacing (119 +/- 10 ms before, 106 +/- 13 ms during pacing, P = 0.002) and atrial multisite pacing (123 +/- 20 ms before, 112 +/- 11 ms during pacing, P = 0.5) shortened P wave duration. Atrial pacing caused a significant (P < 0.002) prolongation of atrial contraction [corrected] delays from 24 +/- 21 ms to 41 +/- 26 ms during conventional right atrial pacing, and reversed the right-to-left into a left-to-right contraction sequence in 20 of 21 patients during right atrial septal pacing (atrial conduction delay during sinus rhythm: 34 +/- 23 ms vs -37 [corrected] +/- 26 ms during atrial pacing, P < 0.0001). Atrial multisite pacing caused a nonsignificant shortening of the usual right-to-left contraction delay from 22 +/- 34 ms to 11 +/- 18 ms. The optimal left heart AV delay during AV sequential pacing was significantly (P = 0.002) shorter during right atrial septal pacing (108 +/- 38 ms) than during conventional right atrial pacing (152 +/- 33 ms). During conventional right atrial pacing the optimal right heart AV delay was significantly (P = 0.029) shorter than the optimal left heart AV delay. The opposite relation was observed for right atrial septal pacing (P = 0.033). CONCLUSIONS: Interatrial septal pacing does not synchronize right and left atrial contractions. It reverses the atrial mechanical timing from a right-to-left to a left-to-right contraction sequence, and requires the setting of shorter AV delays during dual chamber pacing if based on the optimization of left heart timing. Interatrial septal pacing is a technique which allows pacing of the left atrium from a right atrial site, rather than a single site approach to biatrial pacing.

Adolescent↗

Borna disease in a free-ranging lynx (Lynx lynx).

A free-ranging lynx (Lynx lynx) was shot because of its abnormal behavior. Histopathological examination revealed a nonsuppurative meningoencephalitis. In situ hybridization, immunohistochemistry, and reverse transcriptase PCR analysis showed the presence of Borna disease virus infection in the brain. To our knowledge, this is the first confirmed case of Borna disease in a large felid.

Animals↗

Miniaturization of a functional transcription assay in yeast (human progesterone receptor) in the 384- and 1536-well plate format.

Miniaturization of high throughput screening assays to high-density microplate formats (384 or 1536 wells) is currently the focus of research activity in modern drug discovery facilities. In this article, we describe the adaptation of a fluorescence-based functional transcription assay in yeast for assessing modulators of human progesterone receptor to the 384- and 1536-well microplate format, comparing the experimental results to those obtained in the well-established 96-well format. The experiences gained from the optimization of the liquid-handling procedures and the miniaturization of an enzyme assay (beta-galactosidase) were implemented. Thus optimized pipetting protocols were developed to perform a reporter gene assay in yeast in microplate formats of higher density. In the functional transcription assay in yeast, the reporter gene expression showed the expected dependence on the ligand's dose and affinity in principle in all three microplate formats. For the first time, this assay system has been established in the 1536-well microplate format using CyBi-Well 96/384/1536 as the liquid-handling unit. The comparison of the signal:background ratios showed a lower sensitivity of the assay in the microplate formats of higher density. This study is an example of a successful miniaturization of a yeast cell-based assay to high-density plate formats on the basis of a careful adaptation procedure and optimized liquid-handling conditions.

Cloning, Molecular↗