Do battery depletion indicators reliably predict the need for pulse generator replacement?

Abstract

The aim of this study was to test the validity of battery depletion indicators to forecast end of service (EOS) in dual chamber pulse generators (PG). Two additional approaches for prediction of EOS were evaluated as well: the real-time telemetry of cell impedance and a battery stress test (BST) that used a transitory increase in pacing rate. The study population consisted of 119 patients with Intermedics dual chamber PG models Cosmos II and Relay, in which cell impedance had exceeded 2.5 k omega. The patients were followed in 6-month intervals. If the interrogation of the PG or the BST prompted the appearance of the intensified follow-up indicator (IFI), the next follow-up was scheduled within 2 months. PG replacement was performed on physician's discretion or immediately on appearance of the elective replacement indicator (ERI), regardless of the method of ERI provocation. During a period of 2 years/and 9 months, 33 patients underwent PG replacement. Out of 21 patients with positive ERI indicators, only 5 had positive warning indicators of approaching battery depletion in the preceding follow-up (IFI during BST, n = 4; ERI during BST n = 1). The majority of patients (n = 16, 76%) revealed ERI without prior activation of IFI, neither spontaneous nor during the BST. Four of these 16 ERI-positive patients had cell impedance values far below the ERI limits of the manufacturer. Based on battery depletion indicators, an exact prediction of EOS of dual chamber pacemakers is not possible. Measuring battery impedance allows for a statistical estimation of remaining service life but it may be misleading in the individual case. A BST that is based on a temporary increase of pacing rate is invalid in forecasting battery depletion. As activation of the ERI can trigger an abrupt change to the VVI backup mode, pacemaker dependent patients with low programmed basic pacing rates may be hemodynamically compromised by an unexpected activation of ERI. Close monitoring intervals and PG replacement before appearance of the ERI is recommended in those patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Kindermann, M Berg, K Pistorius, H Schwerdt, G Fröhlig. 2001. Do battery depletion indicators reliably predict the need for pulse generator replacement?. https://doi.org/10.1046/j.1460-9592.2001.00945.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Geophysical imaging of root-zone, trunk, and moisture heterogeneity.

The most significant biotic and abiotic stress agents of water extremity, salinity, and infection lead to wood decay and modifications of moisture and ion content, and density. This strongly influences the (di-)electrical and mechanical properties and justifies the application of geophysical imaging techniques. These are less invasive and have high resolution in contrast to classical methods of destructive, single-point measurements for inspecting stresses in trees and soils. This review presents some in situ and in vivo applications of electric, radar, and seismic methods for studying water status and movement in soils, roots, and tree trunks. The electrical properties of a root-zone are a consequence of their moisture content. Electrical imaging discriminates resistive, woody roots from conductive, soft roots. Both types are recognized by low radar velocities and high attenuation. Single roots can generate diffraction hyperbolas in radargrams. Pedophysical relationships of water content to electrical resistivity and radar velocity are established by diverse infiltration experiments in the field, laboratory, and in the full-scale 'GeoModel' at Kiel University. Subsurface moisture distributions are derived from geophysical attribute models. The ring electrode technique around trunks images the growth ring structure of concentric resistivity, which is inversely proportional to the fluid content. Healthy trees show a central high resistivity within the dry heartwood that strongly decreases towards the peripheral wet sapwood. Observed structural deviations are caused by infection, decay, shooting, or predominant light and/or wind directions. Seismic trunk tomography also differentiates between decayed and healthy woods.

Electric Impedance↗

Technology review: Esophageal impedance monitoring.

Intraluminal impedance monitoring is a new technique that can be used to detect the flow of liquids and gas through hollow viscera. In combination with manometry, it is used for esophageal function testing and while manometry provides information on contractile activity, impedance provides information on esophageal bolus transit. This is especially useful in patients with nonobstructive dysphagia. However, impedance monitoring appears to be less suitable for the evaluation of patients with achalasia. When used in combination with esophageal pH monitoring, impedance monitoring makes gastroesophageal reflux monitoring more complete because it allows recognition of both acidic and weakly acidic reflux episodes. The results of several studies suggest that impedance-pH monitoring is useful in the evaluation of patients with PPI-resistant typical reflux symptoms, chronic unexplained cough, excessive belching, and rumination.

Electric Impedance↗