High atrial pacing impedance: efficient or wasteful? A comparison of an active and a passive fixation lead.

We compared the stimulation characteristics of two atrial fixation leads: the CPI model 4269 (n = 45) and Cordis-Telectronics model 327-752 (n = 42). The CPI lead uses an active fixation method, whereas the Cordis-Telectronics lead is fixated passively. Impedance and threshold were measured at implant and during 12 months of follow-up. P wave sensing was good with both types of leads. Follow-up of these 87 leads showed that both the impedance and threshold increased with the active leads, but not with the passive fixation leads. In the active fixation group, regardless of the high atrial pacing impedance, 93% could still be programmed to 2.5 V-0.6 msec (with a 2:1 threshold safety margin). It is concluded that the high chronic pacing impedance of the active fixation leads will be beneficial on current drain if no major increase in pacing threshold occurs simultaneously.

Cardiac Pacing, Artificial↗

External vibration interference of activity based rate responsive pacemakers.

The change of the pacing rate in response to external vibration interference was assessed in four rate responsive pacemakers with a piezoelectric crystal (Medtronic Activitrax 8403, Siemens Sensolog 3, Biotronik Ergos 01, and Medtronic Legend 8417) and one with an accelerometer (CPI Excel VR 1119). They were tested in the laboratory. External vibration was simulated in vitro by exposing the different pacemakers to a controlled sinusoidal vibration force generated by a Millar pressure vibration amplifier type MGM-30 (Millar Instruments, Inc., Houston, TX, USA). All pacemakers were programmed at standard settings. Two types of vibration forces were applied: (1) one with varying amplitude but with constant vibration frequency; and (2) one with varying frequency but with constant vibration amplitude. In this manner curves of pacing rate versus vibration forces versus vibration frequency were obtained. High vibration forces and low vibration frequencies were associated with the highest pacing rate response. In this experimental setting, the pacemaker based on the accelerometer principle apparently was the least sensitive to high frequency vibrations, which are known to be related to environmental interference. It also seemed more appropriately responsive in the lower frequency range, which is more appropriate for the detection of true physiological activity.

Acceleration↗

Predictive value of the P wave at implantation for atrial fibrillation after VVI pacemaker implantation.

This study assesses the value of P wave measurements on the surface ECG at implantation, in the prediction of atrial fibrillation in VVI paced patients. From a consecutive series of 320 pacemaker implantations 172 VVI paced patients for symptomatic atrioventricular block (AVB) (n = 126; mean age 69 +/- 14) or sick sinus syndrome (SSS) (n = 56; mean age 68.6 +/- 12) and in sinus rhythm at implantation were used in this study. P wave duration in V1 is correlated with the incidence of atrial fibrillation during 5 years of follow-up. V1 at implantation was significantly longer (114.6 +/- 2.7 msec) in the patients who developed atrial fibrillation than in those who did not (91.9 +/- 2.7 msec) (P < 0.001). Although positive predictive accuracy increases progressively for higher V1 values for AVB and SSS, the negative predictive and diagnostic accuracy of V1 criteria were less in SSS. Application of the Bayes' theorem showed that in SSS the probability to develop atrial fibrillation is 33% for V1 < 110 msec and is for V1 < 90 msec still higher than that reported in DDD paced patients. In the AVB group the probability to develop atrial fibrillation is 8% for V1 < 110 msec and 6% for V1 < 100 msec. It seems, therefore, that atrial stimulation (AAI or DDD) is always indicated in SSS. In AVB with V1 < 100 msec, DDD pacing, if not needed for other indications, apparently does not offer much benefit in the prophylaxis of atrial fibrillation.

Aged↗

Evolution of P wave characteristics after pacemaker implantation.

This study is an investigation of the long-term effects of VVI pacing on the atrium as derived from the evolution of P wave characteristics of 285 patients. The occurrence of left and right atrial disease is demonstrated as well as the evolution of left atrial hypertrophy in some cases. A comparison is made with DDD pacing and special attention is given to the progression to atrial fibrillation.

Aged↗

Simultaneous bipolar pacing and sensing during EPs.

Bipolar pacing and sensing-recording on the same electrode is a problem during pacemaker implantation as well as during electrophysiological studies. A method is described that makes this possible. By using bipolar simultaneous sensing-pacing on the same electrode, the system can record local repolarization after a depolarization controlled by stimulation. The bipolar-paced evoked potential is useful as an indicator to drive a bipolar QT rate responsive pacemaker. Even more, during EPS it can be used to detect capture during tachycardia stimulation and to measure the exact refractory period.

Carbon↗