PubMed Health⌕ Search

Biomedical subjects

M Dandel

Publications and source records attributed to M Dandel.

At least 19 recordsLinked to original sources

[Pulmonary bleeding after lung transplantation].

BACKGROUND: Bronchial arteries are not anastomosed during lung transplantation. We analyzed the occurrence of pulmonary hemorrhage after transplantation. PATIENTS AND METHODS: 235 patients were included. RESULTS: We observed pulmonary bleeding in 4/235 patients (1.7 %). All four cases were due to transplant-specific disorders (arrosion of pulmonary artery in three cases, coagulopathy in one patient). CONCLUSIONS: The analysis shows, that usual pulmonary hemorrhage does not occur in lung transplant recipients. This underlines the role of bronchial arteries in pulmonary hemorrhage of non-LTX-patients.

Adolescent↗

[Non-invasive monitoring of rejection after cardiac transplantation. The method and retrospective analysis of data on 734 patients].

BACKGROUND AND OBJECTIVE: Endomyocardial biopsy is the gold standard for monitoring rejection in cardiac recipients. The death rate due to rejection with this invasive method is 5-6 % in the first postoperative year. The aim of this retrospective data analysis from cardiac recipients was to prove the diagnostic reliability of a non-invasive electrophysiological method for rejection monitoring. PATIENTS AND METHODS: We daily analyzed the QRS-complex amplitude of the intramyocardial electrogram, which we received over a period from one year via a pacemaker with a telemetric capability. The diagnostic guideline for a suspected rejection was the reduction of the QRS-complex amplitude by more than 8 %. Out of 734 patients 558 were included in the study. Biopsy was only performed when the non-invasive rejection monitoring data (QRS-complex amplitude plus echocardiography) showed a discrepancy for rejection. RESULTS: None of the patients died due to rejection, 273 at least once underwent a biopsy, and 285 never had a biopsy. The method reached a sensitivity of 0.9777, a specificity of 0.9634, a negative predictive value of 0.9850, and a positive predictive value of 0.9459. CONCLUSION: Daily electrophysiological non-invasive monitoring of rejection seems to be superior to endomyocardial biopsy. Death of patients due to rejection can be minimised. The number of necessary biopsies can be drastically reduced when compared to the usual number performed.

Adolescent↗

Reliability of tissue Doppler wall motion monitoring after heart transplantation for replacement of invasive routine screenings by optimally timed cardiac biopsies and catheterizations.

BACKGROUND: Invasive screenings at predefined time intervals for acute rejection and transplant coronary artery disease (TxCAD) are standard procedures. However, cardiac biopsies and catheterizations are distressing and risky for the patients and are also costly. We assessed the reliability of pulsed-wave tissue Doppler imaging (PW-TDI) for the timing of invasive examinations in heart recipients in an attempt to avoid unnecessary endomyocardial biopsies (EMBs) and catheterizations. METHODS AND RESULTS: PW-TDI obtained at the basal left ventricular posterior wall before 408 EMBs and 293 catheterizations was tested for its diagnostic value regarding rejection and TxCAD with the use of International Society of Heart and Lung Transplantation biopsy grading, coronary angiography, and intravascular ultrasound as standards. Early diastolic peak wall motion velocity and relaxation time showed high sensitivities for clinically relevant rejection diagnosis (90.0% and 93.3%, respectively). The negative and positive predictive values for rejection of diastolic parameter changes appeared high enough (up to 96% and 92%, respectively) to allow a reliable noninvasive PW-TDI monitoring with efficiently timed, instead of routinely scheduled, EMBs. At definite cutoff values for systolic parameters, the probability for TxCAD reached 92% to 97%. The Fisher classification functions allowed TxCAD exclusion with 80% probability. CONCLUSIONS: Without diastolic parameter changes, acute rejection can be practically excluded, and serial PW-TDI can save patients from routine EMBs. The high specificity and negative predictive value for TxCAD of reduced systolic peak velocities and extended systolic time allow optimized timed catheterizations. Peak systolic velocity and systolic time allow diagnostic classifications that enable patients without known TxCAD but with high risk for catheterization to be spared routine angiographies.

Adult↗

Bridging-to-recovery.

BACKGROUND: Patients with end-stage heart failure placed on a cardiac assist device show at least some degree of improvement of cardiac function. In a subgroup of selected patients, some hearts recovered considerable function. In these patients the device was removed and cardiac transplantation was no longer necessary. We report our long-term experience with these weaned patients. METHODS: As of today, 512 cardiac assist devices of various types (Berlin Heart, Berlin, Germany; Novacor, World Heart, Ottawa, Ontario, Canada; TCI, ThermoCardio Systems, Inc, Woburn, MA; DeBakey, Micromed Technology Inc, Houston, TX) were implanted in patients with end-stage heart failure in our institution. Of these, 95 patients belonged to a subgroup of patients with nonischemic, idiopathic, dilated cardiomyopathy who were implanted with a left ventricular support system (Novacor 84, TCI 10, Berlin Heart 1) between 1994 and 2000. All were routinely examined by echocardiography for improvement of cardiac function. The left ventricular diameter in diastole (LVIDd) and left ventricular ejection fraction (LVEF) served as the main parameters to assess changes in cardiac performance. Under the conditions of a running device, an LVIDd below 60 mm and an LVEF above 40% were the criteria to do further echocardiographic studies when the pump was turned off for up to 20 minutes. RESULTS: Twenty-eight patients (26 men, 2 women; ages 18 to 64 yrs; history of heart failure, 1 to 17 yrs) fulfilled the criteria of improved cardiac performance and were weaned from the device. Since then, 16 patients have continued "normal" heart function with follow-up times ranging from 1 month to 5.5 years (group B). Three patients died of noncardiac causes (group C). Eight patients were transplanted from 1 to 17 months later and one died on the waiting list (group A). Statistically significant differences between groups A and B were calculated for the duration of heart failure (9 versus 2 years, p = 0.0002). Differences in LVIDd before removal of the device (57 versus 51 mm, p = 0.0420), LVEF after 2 months of unloading (30 versus 49%, p = 0.0300), and LVEF preexplantation (43 versus 52%, p = 0.0001) were significant. Overall, 17% of the cohort of 95 patients were weaned successfully. CONCLUSIONS: Weaning from cardiac assist devices is feasible for selected patients; it saves donor hearts and is preferred to cardiac transplantation. However, as of today no reliable parameter predicts outcome after weaning and none determines the possibility of device removal before implantation in advance.

Adolescent↗

Immunoglobulin adsorption in patients with idiopathic dilated cardiomyopathy.

BACKGROUND: Idiopathic dilated cardiomyopathy (IDC) frequently is a progressive disease without causative therapy options. Following the hypothesis that in certain patients autoantibodies against cardiac structures may induce, maintain, or promote the progression of the disease, we investigated whether the elimination of these autoantibodies through immunoadsorption would improve cardiac function. METHODS AND RESULTS: This prospective case-control study included 34 patients with IDC. Each patient presented with moderate to severe heart failure and evidence of autoantibodies directed against beta(1)-adrenoceptors (beta(1)-AABs). Seventeen patients received standard medical therapy (control group), whereas 17 were also treated with immunoadsorption (treatment group) to eliminate beta(1)-AABs. A 1-year follow-up included echocardiographic assessment of left ventricular ejection fraction and internal diameters, beta(1)-AAB levels, and clinical status every 3 months. Within 1 year, the mean+/-SD left ventricular ejection fraction rose from 22.3+/-3.3% to 37.9+/-7.9% (P=0.0001) in the treatment group, with a relative increase of 69.9%. However, in the control group, no overall increase was seen (from 23.8+/-3.0% to 25.2+/-5.9%, P=0. 3154). Left ventricular diameter in diastole decreased by 14.5% from 74.5+/-7.1 to 63.7+/-6.0 mm in the treatment group (P=0.0001) and by 3.8% (P=0.2342) in the control group. In the treatment group, the NYHA functional rating improved after immunoadsorption (P=0.0001). beta(1)-AABs did not increase anew. CONCLUSIONS: In IDC, the use of immunoadsorption is superior to the use of standard medical therapy. It significantly improves cardiac performance and clinical status.

Autoantibodies↗

[Glycogenosis type IV as a seldom cause of cardiomyopathy - report about a successful heart transplantation].

We report about a 17 year old male patient with a cardiomyopathy secondary to type IV glycogenosis (Andersens disease) and class II immunoglobulin deficiency who underwent cardiac transplantation. The patient first developed symptoms of heart failure at the age of twelve. The histologic diagnosis was cardiomyopathy secondary to glycogenosis. In addition, the patient suffered recurrent pulmonary infections and developed bronchiectases in the left lower lobe. This region was atelectatic since he was eleven. The patient did have two younger brothers who died of congestive heart failure at the age of nine and ten. Neither his parents nor anybody else of his relatives had a history of heart failure or glycogenosis. Since the patient suffered recurrent cardiac decompensations with the need for catecholamines he was accepted for cardiac transplantation although several relative contraindications to transplantation such as cachexia, myopathy, immunglobulin deficiency and bronchiectases had been present. The patient was transplanted successfully. The postoperative weaning from the respirator was markedly prolonged and complicated by pulmonary infection. Furthermore, mobilization was retarded. One year after transplantation, he is in a good condition without pulmonary or systemic infection. Right ventricular endomyocardial biopsies did not show recurrence of glycogenosis in the donor organ.

Adolescent↗

Nitric oxide inhalation in the treatment of right ventricular dysfunction following left ventricular assist device implantation.

BACKGROUND: Following left ventricular assist device (LVAD) implantation in end-stage heart failure, the management of right ventricular dysfunction presents a therapeutic problem unresolved by conventional drug therapy (catecholamines, nitrates, and prostacyclin). This study was performed to investigate the effects of supplemental inhalation of nitric oxide (NO), a selective pulmonary vasodilator, postoperatively and prospectively. METHODS AND RESULTS: Intraindividual dose titration of NO was performed (0 to 40 ppm) according to a standardized protocol. Thereafter treatment was continued with the individually most effective dose of NO (25 to 40 ppm). In 8 consecutive male patients presenting with right ventricular dysfunction postoperatively, a significant dose-dependent improvement in hemodynamic function was observed: pulmonary vascular resistance decreased from 336+/-110 to 210+/-59 dynes x s x cm(-5) (P<.0001), cardiac index rose from 2.0+/-0.4 to 2.7+/-0.4 L x min(-1) x m(-2) (P<.003) at 40 ppm; doses of >20 ppm were effective in increasing cardiac index (P<.05). With continuous NO inhalation up to 48 hours, pulmonary vascular resistance decreased further to 155+/-33 dynes x s x cm(-5) (P<.0001) as the cardiac index increased to 3.3+/-0.6 L x min(-1) x m(-2) (P<.003). Pulmonary artery pressure decreased (P<.0001) as did systemic vascular resistance with hemodynamic improvement (P<.01). Central venous pressure and mean arterial pressure remained unchanged. Right ventricular ejection fraction at transesophageal echocardiography increased from 24+/-7% to 44+/-7% (P<.01) at the end of the study, and right ventricular end-diastolic volume decreased (P<.05). Weaning from NO therapy was successful at 2 to 8 days, and all patients were extubated. Right ventricular function remained stable thereafter. CONCLUSIONS: In the treatment of right ventricular dysfunction following LVAD implantation, inhalation of NO markedly decreased right ventricular afterload by its selective vasodilating effects on the pulmonary circulation without producing systemic hypotension; this merits further evaluation.

Administration, Inhalation↗

Weaning from mechanical cardiac support in patients with idiopathic dilated cardiomyopathy.

BACKGROUND: Implantation of mechanical cardiac support systems (MCSS) in patients with idiopathic dilated cardiomyopathy (IDC) may improve cardiac function and allow explantation of the device. We report of long-term effects of ventricular unloading on cardiac function, humoral anti-beta1-adrenoceptor autoantibodies (A-beta1-AABs), and myocardial fibrosis. METHODS AND RESULTS: Seventeen patients in New York Heart Association functional class IV with nonischemic IDC received MCSS. All had a cardiac index of < 1.6 L x min(-1) x m(-2) of body surface area, a left ventricular ejection fraction (LVEF) of <16%, and a left ventricular internal diameter in diastole (LVIDd) of >68 mm and tested positive for A-beta1-AABs. Echocardiographic evaluation, serum tests for A-beta1-AABs, and histological assessment of myocardial fibrosis were performed before and after MCSS implantation. The mean support duration was 230+/-201 days. Six patients died, four were transplanted, and two are still on MCSS. Five patients with significant cardiac recovery (mean LVIDd, 54+/-2.3 mm; LVEF, 47+/-3.7%) were weaned after 160 to 794 days and are now device free for 51 to 592 days. A-beta1-AABs disappeared gradually during MCSS without increase after weaning; cardiac function and volume density of fibrosis remained normal. Nine patients' cardiac function hardly improved during ventricular unloading. CONCLUSIONS: Cardiac function can be normalized in selected patients with end-stage IDC by MCSS. The degree of preoperative myocardial fibrosis may be an indicator for outcome; A-beta1-AABs can be used to monitor myocyte recovery. Weaning from MCSS offers an alternative to cardiac transplantation in certain patients.

Adult↗

[Temporary mechanical left heart support. Recovery of heart function in patients with end-stage idiopathic dilated cardiomyopathy].

BACKGROUND: Implantation of a mechanical cardiac support system (MCSS) in patients with idiopathic dilated cardiomyopathy (IDC) may improve cardiac function and allow explantation of the device. Our experience now includes 13 patients who have been "weaned" from MCSS and we report about the overall results of this treatment as well as the effects of ventricular unloading on cardiac function, anti-beta 1-adrenoceptor-autoantibody (A-beta 1-AAB) level and the degree of myocardial fibrosis. METHODS: 13 patients with non-ischemic IDC who had been admitted here in cardiogenic shock (CI < 1.61.min-1.m2, left ventricular ejection fraction [LVEF] < 16% and left ventricular internal diameter in diastole [LVIDd] > 68 mm) and who all tested positive for A-beta 1-AABs were implanted with an uni-(12 patients) or a biventricular (1 patient) mechanical assist device. Echocardiographic evaluation and A-beta 1-AAB-level-monitoring was routinely performed after implantation and explantation of the MCSS and the degree of myocardial fibrosis was assessed at the time of implantation and after explantation. RESULTS: During a mean duration of mechanical support of 236 +/- 201 days (range: 30 to 794 days), LV-EF improved to a mean of 46% and LVIDd decreased to a mean value of 56 mm in these 13 patients. A-beta 1-AABs decreased and disappeared 11.7 weeks after implantation of the device and did not reincrease thereafter. The highly pathologic degree of fibrosis at the time of implantation diminished to normal values about 1 year after explantation. One patient died of anesthesiologic complications and another patient shortly presented with a new episode of cardiac insufficiency 6 months after explantation. He was implanted again with an univentricular assist device was successfully transplanted 3 weeks later. Mean observation period of the remaining 11 patients now amounts to 12.6 +/- 9.77 (range: 3 to 26) months after explantation of the device--as of May, 31, 1997--with a cumulative observation period of 139 patient months. CONCLUSION: Temporary implantation of a MCSS may normalize cardiac function in selected patients with IDC. The striking degree of myocardial fibrosis can reduce to normal values after explantation of the device. A-beta 1-AABs disappear during ventricular unloading and do not increase thereafter. "Weaning" from mechanical device may constitute an alternative treatment to cardiac transplantation in selected patients.

Adult↗