In vitro simulation and quantification of temporal jitter artifacts in ECG-gated dynamic three-dimensional echocardiography.

The image quality of dynamic 3-D echocardiography is limited by temporal jitter artifacts that result from the asynchronous acquisition of video frames with the cardiac cycle. This paper analyzes the source and extent of these artifacts using in vitro studies. Dynamic 3-D images of a myocardial motion phantom were reconstructed and analyzed for eight cardiac motion patterns. The extent of temporal jitter artifacts was quantified, first, from the images by computing temporal jitter maps and, second, predicted from the motion waveforms. Temporal jitter appeared as a pattern of streak artifacts converging at the axis of rotation of the imaging plane, for the rotational scanning approach used in our study. The results of the experimental analysis techniques were compared with the waveform analysis using linear regression analysis. The least squares line showed good correlation between the data (r > 0.9) and its deviation from the line of identity was calculated to be <9%.

Artifacts↗

Evaluation of 3-D colour Doppler ultrasound for the measurement of proximal isovelocity surface area.

Three-dimensional (3-D) colour Doppler ultrasound (US) enables flow rate estimation across a diseased valve without the need for a priori geometric assumptions. This study quantitatively evaluates the accuracy of 3-D colour Doppler US for measuring the flow rate (8. 3-75 mL/s) through a valve using the proximal flow convergence field. Flow rate measurements by this 3-D technique underestimate flow through finite circular orifices due to two major sources of error: 1. surface area slicing technique (18.3% +/- 3.8%) and 2. Doppler angle effect (41.0% +/- 1.5%). Combined total underestimation is 51% +/- 3.3%. To utilize 3-D US, the development of an improved proximal isovelocity surface area (PISA) measurement technique and a correction factor for the Doppler angle effect is required.

Blood Flow Velocity↗

Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass.

Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEMinter = 13.5%, %SEMintra = 11.4%, and for 2D echocardiography was %SEMinter = 21.5%, %SEMintra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography.

Analysis of Variance↗

Optical detection of triggered atherosclerotic plaque disruption by fluorescence emission analysis.

Fluorescence emission analysis (FEA) has proven to be very sensitive for the detection of elastin, collagen and lipids, which are recognized as the major sources of autofluorescence in vascular tissues. FEA has also been reported to detect venous thromboemboli. In this paper we have tested the hypothesis that FEA can reproducibly detect in vivo and in vitro triggered plaque disruption and thrombosis in a rabbit model. Fluorescence emission (FE) spectra, recorded in vivo, detected Russell's viper venom (RVV)-induced transformation of atherosclerotic plaque. FE intensity at 410-490 nm 4 weeks after angioplasty was significantly lower (P < 0.0033 by analysis of variance) in RVV-treated rabbits when compared to control animals with stable plaque. FE spectral profile analyses also demonstrated a significant change in curve shape as demonstrated by polynomial regression analysis (R2 from 0.980 to 0.997). We have also demonstrated an excellent correlation between changes in FE intensity and the structural characteristics detected at different stages of "unstable atherosclerotic plaque" development using multiple regression analysis (R2 = 0.989). Thus, FEA applied in vivo is a sensitive and highly informative diagnostic technique for detection of triggered atherosclerotic plaque disruption and related structural changes, associated with plaque transformation, in a rabbit model.

Angioplasty, Balloon↗

3-D image guidance for minimally invasive robotic coronary artery bypass.

BACKGROUND: The introduction of a robot-assisted microsurgical system has made endoscopic coronary artery bypass grafting (ECABG) possible. Despite the success of this approach, surgeons still require better visualization tools for pre-surgical planning and intra-operative image guidance. Such visualization tools could, for example, assist in the placement of thoracic ports to acquire optimum access to the target vessels. In this paper we discuss the essential steps toward image-guided completely endoscopic coronary bypass surgery with robot assistance, and we present our preliminary efforts toward the development of a three-dimensional (3-D) virtual cardiac surgical planning platform (VCSP) for ECABG. METHODS: Preoperative 3-D images of the thorax acquired with computed tomography and electrocardiogram-gated magnetic resonance imaging are imported into VCSP. Using VCSP, a user may interactively visualize and manipulate the simulated thoracic ports in 3-D within the reconstructed thoracic region. We have also implemented a virtual endoscope to simulate the endoscopic view observed by the surgeon during the operation. Once the port placements for optimal access to the target vessels are determined, the positions of the simulated tools can be recorded and marked on the patient to specify the positions for port incisions. RESULTS: A static thorax phantom was used to verify the port placements obtained from VCSP simulations. The angles and the distances between the ports, the endoscope and the markers that were placed on the surface of the phantom were measured, and the results were compared with those obtained from simulation. The physical measured distances and angles agreed with the simulated results with average errors of 4 mm and 2 degrees, respectively. CONCLUSIONS: The VCSP image-guided surgical system allows a surgeon to visualize a patient's thorax in a 3-D interactive environment for planning surgical procedures, and to determine the optimum port placement based on preoperative 3-D images. However, during an operation, the positions and orientation of the heart and the coronary arteries are changed from their corresponding locations in the preoperative images due to carbon-dioxide insufflation, lung deflation, and dynamic motions of the beating heart. One of our future goals of this project is the use of mathematical models that correct for these changes so that our system could be applied to intra-operative image guidance.

Adult↗

Application of dynamic computed tomography for measurements of local aortic elastic modulus.

A novel computed tomographic (CT) technique used for the instantaneous measurement of the dynamic elastic modulus of intact excised porcine aortic vessels subjected to physiological pressure waveforms is described. This system was comprised of a high resolution X-ray image intensifier based computed tomographic system with limiting spatial resolution of 3.2 mm-1 (for a 40 mm field of view) and a computer-controlled flow simulator. Utilising cardiac gating and computer control, a time-resolved sequence of 1 mm thick axial tomographic slices was obtained for porcine aortic specimens during one simulated cardiac cycle. With an image acquisition sampling interval of 16.5 ms, the time sequences of CT slices were able to quantify the expansion and contraction of the aortic wall during each phase of the cardiac cycle. Through superficial tagging of the adventitial surface of the specimens with wire markers, measurement of wall strain in specific circumferential sectors and subsequent calculations of localised dynamic elastic modulus were possible. The precision of circumferential measurements made from the CT images utilising a cluster-growing segmentation technique was approximately +/- 0.25 mm and allowed determination of the dynamic elastic modulus E(dyn) with a precision of +/- 8 kPa. Dynamic elastic modulus was resolved as a function of the harmonics of the physiological pressure waveform and as a function of the angular position around the vessel circumference. Application of this dynamic CT (DCT) technique to seven porcine thoracic aortic specimens produced a circumferential average (over all frequency components) E(dyn) of 373 +/- 29 kPa. This value was not statistically different (p < 0.05) from the values of 430 +/- 77 and 390 +/- 47 kPa obtained by uniaxial tensile testing and volumetric measurements respectively.

Animals↗

Quantitative angiographic blood-flow measurement using pulsed intra-arterial injection.

A technique for quantitative blood-flow measurement using a novel pulsed injection of radiographic contrast agent is reported. A pressurized source of contrast agent is interrupted by a rotary valve at rates ranging from 1 to 30 Hz, producing well-defined boli at the end of a catheter. The position of these boli can be recorded by a digital radiographic system and analyzed by one of several previously reported techniques, to produce quantitative measurements of blood velocity and flow rate throughout the cardiac cycle. The contrast-agent flow wave form produced by the pulsed injector has been measured with an electromagnetic flow meter, for driving pressures ranging from 600 to 1500 kPa. Excellent modulation of the contrast agent is observed for injection frequencies up to 20 Hz, through catheters up to 100 cm in length. Preliminary in vitro angiographic flow measurements have been performed using an x-ray image intensifier, coupled to a linear photodiode array as the digital detector. Both constant flow and pulsatile human blood-flow wave forms were simulated within a 6.4-mm-diam straight tube and monitored with an electromagnetic flow meter. These experiments indicate that the pulsed injector can be used to provide estimates of arterial blood flow over the entire cardiac cycle (including reverse flow), to within about +/-11%, following injection of less than 10 ml of iodinated contrast agent.

Angiography, Digital Subtraction↗

In vitro verification of myocardial motion tracking from phase-contrast velocity data.

The ability to track motion from cine phase-contrast (PC) magnetic resonance (MR) velocity measurements was investigated using an in vitro model. A computer-controlled deformable phantom was used for the characterization of the accuracy and precision of the forward-backward and the compensated Fourier integration techniques. Trajectory accuracy is limited by temporal resolution when the forward-backward technique is used. With this technique the extent of the calculated trajectories is underestimated by an amount related to the motion period and the sequence repetition time, because of the band-limiting caused in the cine interpolation step. When the compensated Fourier integration technique is used, trajectory accuracy is independent of temporal resolution and is better than 1 mm for excursions of less than 15 mm, which are comparable to those observed in the myocardium. Measurement precision is dominated by the artifact level in the phase-contrast images. If no artifacts are present precision is limited by the inherent signal-to-noise ratio of the images. In the presence of artifacts, similar in magnitude to those observed in vivo, the reproducibility of tracking a 2.2 x 2.2 mm2 region of interest is better than 0.5 mm. When the Fourier integration technique is used, the improved accuracy is accompanied by a reduction in precision. We verified that tracking three-dimensional (3D) motion from velocity measurements of a single slice can lead to underestimations of the trajectory if there is a through-plane component of the motion that is not truly represented by the measured velocities. This underestimation can be overcome if volumetric cine phase-contrast velocity data are acquired and full three-dimensional analysis is performed.

Artifacts↗

Estimation of deformation gradient and strain from cine-PC velocity data.

Phase contrast magnetic resonance imaging (MRI) can provide in vivo myocardial velocity field measurements. These data allow densely spaced material points to be tracked throughout the whole heart cycle using, for example, the Fourier tracking algorithm. To process the tracking results for myocardial deformation and strain quantification, we developed a method that is based on fitting the tracking results to an appropriate local deformation model. We further analyzed the accuracy and precision of the method and provided performance predictions for several local models. In order to validate the method and the theoretical performance analysis, we conducted controlled computer simulations and a phantom study. The results agreed well with expectations. Human heart data were also acquired and analyzed, and provided encouraging results. At the signal-to-noise ratio (SNR) level and spatial resolution expected in clinical settings, the study predicts strain quantification accuracy and precision that may allow the technique to become a practical and powerful noninvasive approach for the study of cardiac function, although clinically acceptable data acquisition strategies for three-dimensional (3-D) data are still a challenge.

Aortic Stenosis, Subvalvular↗

Artifacts and signal loss due to flow in the presence of B(o) inhomogeneity.

An in vitro study was performed to investigate the effects of B(o) inhomogeneity on magnetic resonance images of flow. Controlled inhomogeneity gradients (Gi) were applied and the magnitude of the artifacts produced was quantified for different echo delay times (TE). Both steady and pulsatile flows were examined. In the presence of an inhomogeneity gradient, signal loss is apparent if the flow is pulsatile and/or if the slice thickness is large. The signal loss increases with increasing TE and Gi. With pulsatile flow, ghosting artifacts are also generated. These increase in intensity with increasing TE and Gi. In vivo, field inhomogeneity due to susceptibility variations is large enough to produce these effects. Representative time-of-flight images obtained of a normal volunteer with two different TEs demonstrate the effect in vivo. Flow-related signal loss and artifacts, therefore, increase with increasing TE independent of the moments of the applied gradients.

Artifacts↗

Decomposition of inflow and blood oxygen level-dependent (BOLD) effects with dual-echo spiral gradient-recalled echo (GRE) fMRI.

Image contrast with gradient-recalled echo sequences (GRE) used for fMRI can have both blood oxygen level-dependent (BOLD) and inflow components, and the latter is often undesirable. A dual-echo technique can be used to differentiate these mechanisms, because modulation of signal from inflow is common to both echoes, whereas susceptibility and diffusion-related signal losses are larger in the second echo. An efficient dual-echo interleaved spiral sequence was developed for use with a conventional scanner. It uses a k-space trajectory that spirals out from the origin while the first echo is collected, then spirals back in while collecting the second echo. Decomposition of the data provides separate images of the inflow and T2-weighted components. Results demonstrate the decomposition with phantom experiments and with photic stimulation in normal volunteers.

Brain Mapping↗

Fourier tracking of myocardial motion using cine-PC data.

A closed-form integration method is derived and analyzed for computing motion trajectories from velocity field data, particularly as measured by phase contrast (PC) cine MR imaging. By modeling periodic motion as composed of Fourier harmonics and integrating the material velocity of the tracked point in the frequency domain, this method gives an unbiased trajectory estimate in the presence of white measurement noise and eddy current effects. When applied to cine PC data, the method can incorporate compensation for the frequency response of the cine interpolation, offering a further improvement on the tracking accuracy. In simulation and phantom studies, the estimated trajectories were in excellent agreement with the true trajectories. Encouraging results have also been obtained on data from volunteers.

Algorithms↗

A laboratory CT scanner for dynamic imaging.

A high-resolution laboratory CT scanner has been developed for imaging objects undergoing periodic motion. The scanner comprises an x-ray image intensifier, optically coupled to a linear photodiode array. Gated time-evolved projections of a single slice of the moving object are acquired, reformatted, and reconstructed. The resulting series of CT images shows the object at different phases of its motion cycle. The scanner has an adjustable field of view (FOV) and the resolution can be as high as 3.2 mm-1 (for the 40-mm FOV). The spatial resolution depends on the inherent resolution of the scanner and on the object's velocity. For objects moving at 1 cm s-1, the spatial resolution is reduced by 9% in the direction of motion. The signal intensity in the reconstructed image is linear for materials with attenuation coefficients as high as 1.5 cm-1 (for a 90-kVp x-ray beam), with an average accuracy of +/- 0.02 cm-1. The average accuracy of circumference measurements made from the CT images is +/- 0.3 mm. Lastly, an application of this dynamic CT scanner to imaging excised human arterial specimens under simulated physiological pressure conditions is presented as an example.

Aged↗

Elasticity and geometry measurements of vascular specimens using a high-resolution laboratory CT scanner.

Vascular diseases are frequently associated with changes in the mechanical properties of the arterial wall. Existing techniques for studying arterial geometry and mechanical properties in vitro are often destructive, since they involve sectioning of the specimen into strips, or provide average measurements of the mechanical properties over the volume of intact specimens. We developed a high-resolution computed tomography (CT) scanner for in vitro studies of arterial geometry and static elastic properties. The x-ray image intensifier based system can acquire single transverse images, or a volume image, with 2 mm-1 resolution. Images were obtained through an intact abdominal aortic aneurysm at five pressures. The incremental circumferential Young's modulus E(inc) was calculated from the internal and external circumferences, and at physiological pressures E(inc) of the aneurysm was found to be 275 times greater than that of the normal aorta proximal to it. A volume image of the specimen provided landmarks that allowed histological sections to be obtained at locations coincident with those where the elasticity was measured. The histological analysis revealed a sixfold decrease in elastin content in the aneurysm, compared to the normal aorta. We have demonstrated that the static mechanical properties and geometry of vascular specimens can be quantified in vitro with the new high-resolution CT scanner and can be compared subsequently with histological analysis to provide further insight into the understanding of atherogenesis.

Aged↗

Computer-controlled positive displacement pump for physiological flow simulation.

A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the production of nearly uninterrupted steady flow, as well as a variety of pulsatile waveforms, including waveforms with reverse flow. The capabilities of this pump to produce steady flow from 0.1 to 60 ml s-1, as well as sinusoidal flow and physiological flow, such as that found in the common femoral and common carotid arteries are demonstrated. Cycle-to-cycle reproducibility is very good, with an average variation of 0.1 ml s-1 over thousands of cycles.

Arteries↗

Stereotactic surgical planning with magnetic resonance imaging, digital subtraction angiography and computed tomography.

Over the past 2 years at the Montreal Neurological Institute and Hospital, we have evolved an integrated environment for the planning of stereotactic procedures, based on images from magnetic resonance imaging, digital subtraction angiography and computed tomography modalities. These procedures rely on fiducial marker sets which are attached to our 'OBT' stereotactic frame, and which may be recognized in the images. The software package is modular and operates in both minicomputer (PDP-11 and VAX) and IBM personal computer environments. In addition to routine tasks for stereotactic planning, the package also supports dosimetry planning for stereotactic radiosurgery.

Brain↗

Computer-controlled flow simulator for MR flow studies.

A novel computer-controlled flow simulator for use in magnetic resonance (MR) flow experiments was evaluated. The accuracy in constant-flow mode was better than 1%. The accuracy in pulsatile-flow mode was found to be dependent on the interconnecting tubing. The short-term and long-term reproducibilities of pulsatile waveforms were less than or equal to 0.4 mL/sec (1 standard deviation). Increased response times due to the lengths of tubing required in MR flow experiments were surmounted by using a modified tubing configuration and precompensated waveforms. Piston reversal was found not to cause major difficulties in MR flow experiments.

Blood Circulation↗

Tracking of cyclic motion with phase-contrast cine MR velocity data.

A method of computing trajectories of objects by using velocity data, particularly as acquired with phase-contrast magnetic resonance (MR) imaging, is presented. Starting from a specified location at one time point, the method recursively estimates the trajectory. The effects of measurement noise and eddy current-induced velocity offsets are analyzed. When the motion is periodic, trajectories can be computed by integrating in both the forward and backward temporal directions, and a linear combination of these trajectories minimizes the effect of velocity offsets and maximizes the precision of the combined trajectory. For representative acquisition parameters and signal-to-noise ratios, the limitations due to measurement noise are acceptable. In a phantom with reciprocal rotation, the measured and true trajectories agreed to within 3.3%. Sample trajectory estimates of human myocardial regions are encouraging.

Heart↗