Computer-controlled flow simulator for MR flow studies.

Abstract

A novel computer-controlled flow simulator for use in magnetic resonance (MR) flow experiments was evaluated. The accuracy in constant-flow mode was better than 1%. The accuracy in pulsatile-flow mode was found to be dependent on the interconnecting tubing. The short-term and long-term reproducibilities of pulsatile waveforms were less than or equal to 0.4 mL/sec (1 standard deviation). Increased response times due to the lengths of tubing required in MR flow experiments were surmounted by using a modified tubing configuration and precompensated waveforms. Piston reversal was found not to cause major difficulties in MR flow experiments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Frayne, D W Holdsworth, L M Gowman, D W Rickey, M Drangova, A Fenster, B K Rutt. Computer-controlled flow simulator for MR flow studies.. https://doi.org/10.1002/jmri.1880020522

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Understanding the pathophysiology of intra-uterine growth retardation: the role of the 'lower limb reflex' in redistribution of blood flow.

Doppler ultrasound was used to investigate the circulatory redistribution and underlying reflex responses of fetal cardiovascular compensation in 30 small-for-gestational age (SGA) fetuses. The utero-placental bed, umbilical artery and vein, thoracic and abdominal aorta, internal and external cerebral arteries were evaluated. The values were compared to reference ranges constructed from 135 normal pregnancies, correlated to fetal blood gases obtained by cordocentesis and compared to the outcomes. In Group I (mortality and morbidity), all fetuses had loss of end-diastolic frequencies (L-EDF) in the abdominal aorta (100%), but only 20 (87%) and 13 (56%) had L-EDF in the thoracic aorta and umbilical artery respectively. High vascular resistance in the placental bed and low impedance in the middle cerebral and common carotid arteries was found in 14 (61%), 12 (52%) and 20 (87%) fetuses, respectively. In Group II (Healthy infants) two fetuses had high utero-placental vascular resistance and one had brain-sparing. Doppler indices did not always reflect fetal hypoxaemia demonstrating that redistribution in SGA fetuses may not be triggered by a fall in pO2, and that hypoxaemia is an associated pathology but may not be the underlying cause. It is postulated that redistribution in SGA fetuses is regulated by reflex mechanisms (the 'lower limb reflex') which result in severe vasoconstriction in the abdominal aorta, mesentery and carcass, favouring the brain and cardiac muscles. This mechanism explains the good predictive value of L-EDF in the abdominal aorta for poor neonatal outcome (sensitivity, specificity and positive predictive value, all 100%).(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Circulation