Impact of subthalamic nucleus stimulation on the initiation of gait in Parkinson's disease.

The effects of subthalamic nucleus (STN) stimulation on the anticipatory postural actions associated with the initiation of gait were studied in ten patients with idiopathic Parkinson's disease undergoing therapeutic deep brain stimulation. Kinematic, dynamic and electromyographic analysis was performed before and while subjects were starting gait in response to an external cue. Effects of STN stimulation on the standing posture preceding the go signal included significant improvement of the vertical alignment of the trunk and shank, decrease of the hip joint moment, backward shift of the center of pressure (CoP) and reduction of abnormal tonic and/or rhythmic activity in the thigh and leg muscles. Responses to bilateral STN stimulation were more consistent than those evoked by unilateral stimulation. Moreover, comparison between postural changes induced by STN stimulation applied prior to the gait initiation cue and during simple quiet standing revealed more significant responses in the former condition. Effects on the actual gait initiation process included shortening of the imbalance phase, larger backward/lateral displacement of CoP and more physiological expression of the underlying anticipatory muscular synergy. Additional changes were shortening of the unloading phase, shortening of the first-swing phase and increase in the length of the first step. Results demonstrate substantial influence of STN stimulation on functionally basic motor control mechanisms. In particular, the evidence of more significant responses upon attention-demanding conditions and the remarkable effects on postural programmes sub-serving feed-forward regulation of the onset of complex multijoint movements, suggests a consistent action on postural sub-systems relying on cognitive data processing and internal models of body mechanics.

Aged↗

Experimental protocol for the kinematic analysis of the hand: definition and repeatability.

A quantitative and objective method based on the optoelectronic kinematic analysis of hand segments and on the calculation of global and partial parameters, which provide measures of the degree of long finger and thumb extension is proposed for the evaluation of the hand's voluntary range of motion and maximal opening of the fingers and thumb. To test the precision and repeatability of the method, the protocol was applied on 14 healthy subjects (28 hands). The proposed parameters are repeatable and show a precision between 5.5 degrees and 10.4 degrees (mean value: 7.3 degrees), comparable to values obtained with other methods. Advantages of the present approach include simultaneous analysis of all fingers, absence of cumbersome connecting cables and no need for individually customized devices. The method, also applied to the paretic hands of two hemiplegic stroke patients before and after electrical stimulation of the wrist and finger extensor muscles, has shown encouraging results for its clinical feasibility and utility in addition to functional tests.

Adult↗

Procedure for the quantitative evaluation of motor disturbances in cerebellar ataxic patients.

Cerebellar ataxia is a complex motor disturbance that involves the planning and execution of movements and reduces movement accuracy and co-ordination. The quantification of ataxic signs is commonly realised through visual examination of motor tasks performed by the patient and assignment of scores to specific items composing the international co-operative ataxia rating scale (ICARS). The present work studied an experimental procedure to characterise specific aspects of motor disturbances in ataxia objectively. Four tests belonging to the ICARS were considered: walking, knee-tibia test, finger-to-nose and finger-to-finger test. Through a kinematic analysis performed during the above tests, specific indices were defined to quantify velocity, linearity, asymmetry, tremor, instability and smoothness of movement or posture. The procedure was applied to five patients with cerebellar ataxia and to ten healthy adult subjects. Results demonstrated that the patients moved significantly more slowly than the healthy subjects (0.67 against 0.97m s(-1) and 0.81 against 1.02 m s(-1), respectively, for straight walk and finger-to-nose tests) and showed poorer linearity and smoothness behaviour. Velocity, linearity, tremor, smoothness and instability indices showed moderate to good correlation with the corresponding ICARS score. Some of these indices can separately evaluate aspects that are combined in single ICARS subscores. It is concluded that the combination of clinical assessments and instrumental evaluations allows a better insight into ataxic patients' motor disturbances and is a useful tool for the definition and follow-up of rehabilitation programmes.

Adult↗

Trans-femoral amputee gait: socket-pelvis constraints and compensation strategies.

The paper deals with the identification of motor strategies adopted by trans-femoral amputees to compensate for the constraints of hip motion induced by the interference of the socket with the pelvis and, particularly, with the ischial tuberosity. A group of 11 subjects with trans-femoral amputation, three of whom wore two different prostheses, giving a sample size of 14 cases, were studied by gait-analysis protocols: the present paper focuses on the pelvis-thigh kinematics at foot strike. The results showed that, at the prosthetic side, the hip is significantly less flexed and less extended, respectively, at the ipsilateral and contralateral foot strike. Moreover, the pelvis is significantly more anterior tilted at sound foot strike. The anterior step length showed a decreased sound limb anterior step in 12 out of 14 cases. The authors interpret these results as a combination of mechanical constraints and compensatory actions: the reduced prosthetic hip extension is determined by the mechanical constraint involved in the pelvis-socket interference; and the increased pelvis tilt and sound hip flexion occurring at the same time are compensating strategies, adopted by the amputees, in order to obtain a functional step length and symmetrical thigh inclinations. Those factors determine a gait pattern which is functional, only slightly slower than normal gait, and without any perceivable alterations. On the other hand, the authors show that the increased pelvis tilting necessarily overloads the lumbar tract of the spine and may be related to the frequent occurrence of low-back pain in amputee subjects, despite the positive functional gait recovery.

Adult↗

Effects of bilateral subthalamic stimulation on gait kinematics and kinetics in Parkinson's disease.

Subthalamic nucleus (STN) stimulation, a recent surgical approach to Parkinson's disease (PD), has been shown to be effective in relieving motor symptoms. The present study carried out a full body gait analysis, during overground walking, on ten PD patients with bilaterally implanted STN stimulation devices. Walking performance was analyzed on the same day, in four conditions (Stim Off-Med Off, Stim On-Med Off, Stim Off-Med On, Stim On-Med On). The results showed that, on average, STN stimulation alone (S+M-) and L-dopa alone (S-M+), significantly increased gait speed, stride length and the lower limb joint Range of Motion (ROM) with respect to the basal condition (S-M-); also cadence was found to play a role in velocity increase, particularly when L-dopa was administered. Both treatments improved pelvis and trunk kinematics, and power production at the ankle and hip joints. The combination of the two treatments (S+M+) produced an additional effect on gait speed, stride length, ROM of knee and ankle joints, pelvis obliquity and trunk inclination. Given the additive and synergistic effects, it can be hypothesized that the two treatments have different mechanisms of action. Our results confirm the findings of earlier studies that employed treadmill walking.

Aged↗

Microprocessor-controlled optical stimulating device to improve the gait of patients with Parkinson's disease.

Different types of visual cue for subjects with Parkinson's disease (PD) produced an improvement in gait and helped some of them prevent or overcome freezing episodes. The paper describes a portable gait-enabling device (optical stimulating glasses (OSGs) that provides, in the peripheral field of view, different types of continuous optic flow (backward or forward) and intermittent stimuli synchronised with external events. The OSGs are a programmable, stand-alone, augmented reality system that can be interfaced with a PC for program set-up. It consists of a pair of non-corrective glasses, equipped with two matrixes of 70 micro light emitting diodes, one on each side, controlled by a microprocessor. Two foot-switches are used to synchronise optical stimulation with specific gait events. A pilot study was carried out on three PD patients and three controls, with different types of optic flow during walking along a fixed path. The continuous optic flow in the forward direction produced an increase in gait velocity in the PD patients (up to + 11% in average), whereas the controls had small variations. The stimulation synchronised with the swing phase, associated with an attentional strategy, produced a remarkable increase in stride length for all subjects. After prolonged testing, the device has shown good applicability and technical functionality, it is easily wearable and transportable, and it does not interfere with gait.

Aged↗

Performance specification for lower limb orthotic devices.

OBJECTIVE: To establish the range of forces and moments applied to lower limb orthoses during ambulation by routine users. DESIGN: Well-established gait analysis techniques were used to determine the loading at the major joints. It was assumed that the joint moments were transmitted by the orthosis encompassing any particular joint. Two hundred and five assessments of 164 patients were successfully completed by a consortium of four gait laboratories in Europe. The orthosis specification and patient clinical data were also recorded. BACKGROUND: The design and development of orthoses has occurred largely by evolution rather than by formal engineering methods. In particular, formal design has been hampered by a lack of information on the forces and moments applied during ambulation. METHODS: A standard gait analysis procedure was employed to capture the data. In-house biomechanical models were used to calculate the joint loading. Data were normalised with respect to patient weight and leg length. RESULTS: It was found that the median maximum normalised ankle moment transmitted by an ankle foot orthosis was 0.15 and the maximum knee moment was 0.09. The greatest moment transmitted by the hip joint of a hip knee ankle foot orthosis was also 0.09. There was a wide variation in the data due to differences in the impairments of the test subjects. CONCLUSION: It is possible to estimate the loads transmitted by an orthosis using established gait analysis procedures without the need for load measurement transducers. There is now a need both to collect a larger representative dataset and to perform validation studies with transducers.

Adolescent↗

Effects of subthalamic nucleus stimulation and L-dopa in trunk kinematics of patients with Parkinson's disease.

In the advanced phase of Parkinson's disease (PD), high frequency electrical stimulation (HFS) of the subthalamic nucleus (STN) can represent a good therapeutic option, whose effects on walking have been recently quantified by kinematic and dynamic gait analysis. The goal of the present study was to compare, in a group of PD patients, the effects of STN stimulation and of L-dopa on trunk kinematics during walking. The additive effect of these two treatments was investigated as well. Ten idiopathic PD patients implanted bilaterally with a STN stimulation system and ten age-matched controls were studied using a three dimensional motion analyser. Four conditions were considered: with (s+) and without (s-) STN stimulation and with (m+) and without (m-) L-dopa administration. The results showed that both stimulation alone and L-dopa alone significantly increased the stride length and the gait speed, with an additional effect if applied simultaneously. Cadence was more influenced by L-dopa. The range of lateral bending and torsion of the trunk, which were reduced in s-/m-, increased similarly in s-/m+ and in s+/m- conditions. The exaggerated forward inclination of the trunk reduced towards control values in all therapeutic conditions. There was a tendency for L-dopa to increase trunk movements in the frontal plane, similar to events seen in quiet stance. Due to the presence of additive and synergistic effects, we concluded that the mechanisms of action of the two treatments are likely to be different.

Aged↗

Optimised procedure for the calibration of the force platform location.

An innovative optimised method, including an experiment and a mathematical model, for the calibration of the force platform location in the optoelectronic reference frame is proposed. The calibration experiment adopts a bearing-marker testing object contacting the platform and does not directly measure the platform location. The experiment is designed in order to avoid the main drawbacks possibly occurring in commonly adopted methods. The mathematical model of the experiment estimates the expected ground reaction. An optimisation algorithm identifies the optimal platform location as the one that best matches the measured outcome of the calibration experiment with the corresponding model estimate. The innovative calibration procedure has been assessed in terms of inter-tester reliability and compared with commonly used calibration procedures of platform location. These results evidenced how the introduction of such optimised procedure could improve the reliability of the calibrated platform location and, consequently, of the kinetic variables considered in posture and gait analysis.

Algorithms↗

Energy consumption of locomotion with orthosis versus Parastep-assisted gait: a single case study.

STUDY DESIGN: Single case study. OBJECTIVES: To evaluate the energy expenditure during ambulation with the Advanced Reciprocating Gait Orthosis (ARGO), with and without functional electrical stimulation (FES), and with the Parastep system in a single subject, in order to avoid the effect of inter-subject variability. SETTING: The Centre of Sport Medicine and Bioengineering Centre 'Don C Gnocchi' Foundation ONLUS IRCCS, Milano, Italy. METHODS: A single patient (lesion level T5-T6) was trained specifically for each walking system and was evaluated after each training period. The effects of FES on muscle conditioning, spasticity and bone density were also evaluated. The HR/VO2 relationship and the energy cost of locomotion were measured during wheelchair (WHCH) use, during locomotion with ARGO (with and without FES) and Parastep system at different speeds. RESULTS: The following was observed at the end of the whole training: (a) circumferences of both lower limbs and quadriceps forces were increased, whereas fatigue index was slightly decreased, spasticity and bone density were unchanged; (b) compared to WHCH locomotion, the slope of HR/VO2 curves with ARGO was higher (slope difference=51.1 b 1O2(-1)), with ARGO+FES was similar (slope difference=-5.3 b 1O2(-1)) and with Parastep was smaller (slope difference=-55.6 b 1O2(-1)); (c) HR increased linearly with all locomotion systems, but did not rise above 125 bpm with Parastep; (d) the cost of locomotion was higher with Parastep than with ARGO (with and without FES), tested at each velocity; (e) Parastep appears to be easier to use for the subject. CONCLUSIONS: (a) FES can improve ambulation with orthosis, but the cost of locomotion remains very high; (b) the Parastep assisted gait elicits a higher energy expenditure than other orthoses, probably due to the lower speed of locomotion and to the high isometric effort of the stimulated muscles. SPONSORSHIP: This work has been partially supported by the Italian Minister of Public Health (Ricerca Finalizzata IRCCS no ICS030.7/RF97.25).

Adaptation, Physiological↗

Standing-up exerciser based on functional electrical stimulation and body weight relief.

The goal of the present work was to develop and test an innovative system for the training of paraplegic patients when they are standing up. The system consisted of a computer-controlled stimulator, surface electrodes for quadricep muscle stimulation, two knee angle sensors, a digital proportional-integrative-derivative (PID) controller and a mechanical device to support, partially, the body weight (weight reliever (WR)). A biomechanical model of the combined WR and patient was developed to find an optimum reference trajectory for the PID controller. The system was tested on three paraplegic patients and was shown to be reliable and safe. One patient completed a 30-session training period. Initially he was able to stand up only with 62% body weight relief, whereas, after the training period, he performed a series of 30 standing-up/sitting-down cycles with 45% body weight relief. The closed-loop controller was able to keep the patient standing upright with minimum stimulation current, to compensate automatically for muscle fatigue and to smooth the sitting-down movement. The limitations of the controller in connection with a highly non-linear system are considered.

Adult↗

Touch-screen system for assessing visuo-motor exploratory skills in neuropsychological disorders of spatial cognition.

A new computerised test adopting touch-screen technology has been developed to assess the visuo-motor exploration of extra-personal space. The test was derived from well-known paper-and-pencil cancellation tasks used widely in the diagnosis and quantitative assessment of unilateral spatial neglect (USN), a neuropsychological syndrome that is more frequent and severe after damage to the right cerebral hemisphere. A main component deficit of USN is the defective visuo-motor exploration of the side of space contralateral to the side of the lesion (contralesional), namely, in right-sided brain-damaged patients it occurs on the left side and vice versa. The computer-based paradigm consisted of a visuo-motor spatial exploratory task: the subjects were instructed to touch, in any order they wished, all the targets they detected on a computer touch-screen. This measured the time of occurrence and the spatial co-ordinates of each touch event and forwarded the data to the computer for storage; the computer provided feedback to the subject by 'tagging' the touched target. The paradigm allowed the calculation of accuracy and latency indexes and recorded the exploratory pathway taken by each subject. A pilot study was performed in ten normal subjects and 15 brain-damaged patients, with and without psychometric evidence of USN; the results showed that the equipment was able to provide quantitative indexes related to the spatial-temporal aspects of exploratory ability, which are useful for diagnostic purposes, and revealed significant differences between the controls and patients with USN: the overall average values of latency and crossing indexes increased in patients with USN, compared with the controls (latency from 0.77 to 1.90s; path crossing index from 7.0% to 59.5%), and the significantly negative USN patient latency gradient (-2.79 against a null control value) evidenced a worsening of performance towards the left side.

Aged↗

High-frequency electrical stimulation of the subthalamic nucleus in Parkinson's disease: kinetic and kinematic gait analysis.

In the advanced phase of Parkinson's disease (PD), gait disturbances represent one of the main causes of disability. Several studies demonstrated that high-frequency electrical stimulation (HFS) of the subthalamic nucleus (STN) significantly improves the motor symptoms of PD. This study was finalised to quantitatively analyze the effect of STN HFS on gait of PD patients, through a three-dimensional gait analysis system. Ten PD patients were studied, with and without STN HFS. The results demonstrated that STN HFS significantly improves all the main gait parameters in PD patients.

Biomechanical Phenomena↗

Self-marking of anatomical landmarks for on-orbit experimental motion analysis compared to expert direct-marking.

The on-orbit application of movement analysis methodology, on-board space stations, for studying the gravity role in motor functions, requires a careful adaptation of the currently adopted techniques in order to obtain reliable data. In those operative conditions, differently from common on-ground experimental activities, a non-specialist operator, an astronaut of the space station crew, is expected to self-administer the experimental protocol, particularly self-marking specific anatomical landmarks. The present paper proposes a movement analysis methodology, which fits the specific constraints of space activity and matches the objective of maximising reliability and minimising on-orbit time, and reports normative data about accuracy and precision of the self-marking of an extended set of anatomical landmarks. The same set of landmarks has been considered also for direct-marking performed by experts in motion analysis and their results have been compared to self-marking ones. The paper contents will support the design of future space experimental campaigns and is, in general, applicable to any on-ground scientific investigation, possibly increasing data reliability.

Adult↗

Spot check of the calibrated force platform location.

In a movement analysis laboratory, stereophotogrammetric motion capture systems and force platforms must share one absolute reference frame that allows the computation of joint moments and powers. The correct calibration of the platform location identifies the transformation between force plate and absolute reference systems, which determines the spatial coherence among the equipments' measurements. The aim of this study was to develop and test a spot check for the assessment of platform location calibration. Platform location calibration was assessed by comparing the measured outcome of an experiment performed with a pointed rigid rod bearing a set of markers with the corresponding expected results, computed with a model. A set of indices was then proposed to define a confidence volume in which the true ground reaction force is expected to be. The spot check was applied to a real laboratory setup and the effects of simulated platform mislocations were analysed. It was verified that the hip joint moment may be equally affected by a single marker misplacement of about 20mm during platform location calibration, an occurrence that was clearly identified by the spot check, and by a hip centre location inaccuracy of 30mm.

Biomechanical Phenomena↗

A pilot study of myoelectrically controlled FES of upper extremity.

Functional electrical stimulation (FES) of upper limbs can be used for the recovery of some hand functions on patients with CNS lesions. This study deals with the control of FES by means of myoelectrical activity detected from voluntarily activated paretic muscles. The specific aim of this paper is to evaluate the accuracy of myoelectrical control in terms of produced force and movement. For this purpose, a specific device called myoelectrical controlled functional electrical stimulator (MeCFES) has been developed and applied to six tetraplegic patients with a spinal cord lesion and one stroke hemiplegic patient. Residual myoelectric signals from the paretic wrist extensor (m. extensor carpi radialis, ECR) have been used to control stimulation of either the wrist extension (i.e., the same muscle) or thumb flexion. A tracking test based on a visual feedback of the produced force or movement compared to a reference target trajectory was used to quantify control accuracy. A comparison was made between the tracking performances of each subject with and without the MeCFES and the learning process for two of the subjects were observed during consecutive sessions. Results showed that the wrist extension was improved in three out of five C5 SCI patients and the thumb flexion was largely increased in one incomplete C3 SCI patient. The hemiplegic patient showed limited thumb control with the MeCFES but indicated the possibility of a carry over effect. It was found that a low residual natural force resulted in a less accurate movement but also with a large increase (up to ten times) of the muscle output. On the contrary, persons with a medium residual force obtained a smaller amplification of muscle force with a higher tracking accuracy.

Adult↗

Model-based control of FES-induced single joint movements.

A crucial issue of functional electrical stimulation (FES) is the control of motor function by the artificial activation of paralyzed muscles. Major problems that limit the success of current FES systems are the nonlinearity of the target system and the rapid change of muscle properties due to fatigue. In this study, four different strategies, including an adaptive algorithm, to control the movement of the freely swinging shank were developed on the basis of computer simulations and experimentally evaluated on two subjects with paraplegia due to a complete thoracic spinal cord injury. After developing a nonlinear, physiologically based model describing the dynamic behavior of the knee joint and muscles, an open-loop approach, a closed-loop approach, and a combination of both were tested. In order to automate the individual adjustments cited above, we further evaluated the performances of an adaptive feedforward controller. The two parameters chosen for the adaptation were the threshold pulse width and the scaling factor for adjusting the active moment produced by the stimulated muscle to the fitness of the muscle. These parameters have been chosen because of their significant time variability. The first three controllers with fixed parameters yielded satisfactory result. An additional improvement was achieved by applying the adaptive algorithm that could cope with problems due to muscle fatigue, thus permitting on-line identification of critical parameters of the plant. Although the present study is limited to a simplified experimental setup, its applicability to more complex and functional movements can be expected.

Biomechanical Phenomena↗

Analysis of thermal properties of wheelchair cushions with thermography.

Thermal properties of wheelchair cushions have been traditionally studied with thermistor probes, which provide temperature values of limited areas (spot analysis). In this paper, we describe a novel procedure based on thermography for assessing the distribution of temperature over the entire surface of wheelchair cushions. The thermal transient during contact with the body (heating phase) and after use (cooling phase) is considered. The procedure was tested in four different seat cushions (with a gel pad, air-filled cells, gel-filled bubbles and foam-filled bubbles) used by a normal subject. Observed results were compatible with the predicted outcomes based on an analysis of the materials and structures. Specifically: (i) air-filled cushions exhibited the fastest thermal transients, gel cushions the slowest transients, while cushions with a mixed structure exhibited intermediate behaviour; (ii) cushions made from flat surfaces of foam exhibited the highest peak temperatures (30.8 degrees C) as compared to those with air-filled cells (30.35 degrees C) or bubble-shaped surfaces (29.7 degrees C); (iii) the average temperature under the thighs was significantly higher than that under the ischiatic area in all cushions (29.6 degrees C compared with 28.7 degrees C, p < 0.05). It is shown that the present method can be used to differentiate between different cushions. Although the 'macro-analysis' inherent in thermography appears to be suited for improving cushion design, this approach should be further investigated to determine its reliability.

Adult↗