PubMed Health⌕ Search

Biomedical subjects

M Ferrarin

Publications and source records attributed to M Ferrarin.

24 records · Page 2Linked to original sources

EMG signals detection and processing for on-line control of functional electrical stimulation.

The surface EMG signal detected from voluntarily activated muscles can be used as a control signal for functional neuromuscular electrical stimulation. A proper positioning of the recording electrodes in relation to the stimulation electrodes, and a proper processing of the recorded signals is required to reduce the stimulus artefact and the non-voluntary contribution (M-wave). Six orientations and six locations of the recording electrodes were investigated in the present work. A comb filter (with and without a blanking windowing) was applied to remove the signal components synchronously correlated to the stimulus. An operative definition of the signal to noise ratio and an efficiency index were implemented. It resulted that when the recording electrodes were located within the two stimulation electrodes the best orientation was perpendicular to the longitudinal line. However the best absolute indexes were obtained when the recording electrodes were located externally of the stimulation electrodes, and in that case the best orientation was longitudinal. Concerning the filtering procedure, the use of a blanking window before the application of the comb filter, gave the best performance.

Artifacts↗

Paraplegic adaptation to assisted-walking: energy expenditure during wheelchair versus orthosis use.

STUDY DESIGN: To study the energy cost of locomotion during ambulation with different orthoses (HIP Guidance Orthosis Orlau Parawalker (PW), n=4; Reciprocating Gait Orthosis (RGO), n=6; RGO + FNS, n=4). OBJECTIVES: Since high energy costs of locomotion have been proposed as a major reason for early rejection of orthotic use, our aims were (a) to evaluate the impact of functional neuromuscular stimulation (FNS) on energy expenditure during orthosis-assisted ambulation; (b) to study whether energy expenditure data can predict the poor long-term patients' compliance and (c) to assess selection criteria for the assignment of the different types of orthosis. SETTING: The study was completed at the Center of Sports Medicine and Center of Bioengineering, don C. Gnocchi Foundation, IRCCS, Milan, Italy. METHODS: The HR/VO2 relationship and the energy cost of locomotion (C) were studied in 14 patients (lesion level C7-T11) during wheelchair (WHCH) use at various speeds and during locomotion with different orthotic devices. Patients' short- and long-term compliance were assessed by questionnaires evaluating duration of and problems related to orthotic use. RESULTS: (a) In patients using RGO + FNS the slope difference of HR/VO2 curves (deltaslHR/VO2) between WHCH and orthosis was significantly lower than in other groups (-3 beats l(-1) in RGO + FNS vs 43 and 52 beats l(-1) in RGO and PW, respectively); (b) neither C, nor VO2 peak, or deltaslHR/VO2 correlated with orthosis duration of use; (c) in the RGO + FNS group, C was lower at maximal walking speed, which linearly correlated with maximal WHCH speed. CONCLUSION: (a) Electrical stimulation seems to improve locomotion, as a consequence of hemodynamic effects, but does not decrease energy expenditure, which remains high; (b) the poor long-term compliance to orthosis use cannot be predicted by the energy expenditure parameters; (c) the subjects who can reach high speeds by WHCH seem to be the most appropriate for RGO + FNS locomotion.

Adaptation, Physiological↗

The relationship between electrical stimulus and joint torque: a dynamic model.

The knowledge of the behavior of electrically activated muscles is an important requisite for the development of functional electrical stimulation (FES) systems to restore mobility to persons with paralysis. The aim of this work was to develop a model capable of relating electrical parameters to dynamic joint torque for FES applications. The knee extensor muscles, stimulated using surface electrodes, were used for the experimental preparation. Both healthy subjects and people with paraplegia were tested. The dynamics of the lower limb were represented by a nonlinear second order model, which took account of the gravitational and inertial characteristics of the anatomical segments as well as the damping and stiffness properties of the knee joint. The viscous-elastic parameters of the system were identified experimentally through free pendular movements of the leg. Leg movements induced by quadriceps stimulation were acquired too, using a motion analysis system. Results showed that, for the considered experimental conditions, a simple one-pole transfer function is able to model the relationship between stimulus pulsewidth (PW) and active muscle torque. The time constant of the pole was found to depend on the stimulus pattern (ramp or step) while gain was directly dependent on stimulation frequency.

Bias↗

Patient-driven control of FES-supported standing up and sitting down: experimental results.

A patient-driven control strategy for standing-up and sitting-down was experimentally tested on two paraplegic patients by applying functional electrical stimulation (FES) to the quadriceps muscle. The strategy--also known as "patient-driven motion reinforcement" (PDMR)--was developed by computer simulations reported in a former study. It is based on an inverse dynamic model (IDM) that predicts the stimulation pattern required to maintain the movement as it is initiated by the patient's voluntary effort. For reasons of safety and weight relief, the movement was supported by a seesaw construction. After some practice the patients were able to influence the stimulator output and to control the movement by their voluntary effort. Consequently, no pre-programmed reference trajectory was required. As a positive side effect, upper body effort could be minimized compared to trials without FES. To achieve a satisfactory performance of the PDMR controller a careful parameter identification of the inverse dynamic model was fundamental.

Adult↗

Functional control of the hand in tetraplegics based on residual synergistic EMG activity.

A microprocessor controlled device (MeCFES) was used for the investigation of the possibility of restoring hand function in C5 tetraplegics with paralysis of the hand. To date, 3 tetraplegics have been testing the system. The myoelectric signals from wrist extension were recorded and used as control signals for functional electrical stimulation (FES) of thumb adduction/flexion. The results have shown that the device can improve the hand function of tetraplegics. In this part of the work, a hand function test was designed and used to assess the results.

Electric Stimulation Therapy↗

Comparative biomechanical evaluation of different wheelchair seat cushions.

The aim of the present study was to perform a comparative biomechanical analysis of four antidecubitus wheelchair cushions. Thirty wheelchair users were considered divided into three groups: paraplegic subjects (with no cutaneous sensation), neurologic subjects (with intact cutaneous sensation), and elderly subjects. The biomechanical evaluation was performed using a piezoresistive sensor matrix system to quantify parameters referred to pressure distribution, seating surface and posture. Dedicated software was developed for the automatic elaboration of the raw data and the computation of the parameters of interest. Differences among cushion types and subject groups were analyzed. An analysis of time-transient behaviors was also performed. Results showed that no significant differences in pressure peak reduction were found among the four cushions. Moreover, no time-transient behavior was shown by any cushions. However, both the location of pressure peaks and posture were dependent on cushion types. Comparison of the three subject groups showed that elderly subjects had the highest mean pressure and the lowest contact surface, while paraplegics presented the highest pressure peaks. This procedure appears indicated for individualizing the prescription of a wheelchair cushion and even for customizing a cushion to induce a specific posture.

Adult↗