PubMed Health⌕ Search

Biomedical subjects

M H Wisbeski

Publications and source records attributed to M H Wisbeski.

2 recordsLinked to original sources

Experience with PCR screening.

The COBAS AmpliScreen Hepatitis C (HCV) Test, Version 2.0, which is designed for screening pools composed of samples from individual units of blood or plasma, employs a MultiPrep sample processing procedure that simultaneously extracts and concentrates HCV, HIV-1 and Hepatitis B virus particles from plasma. An HCV Internal Control (IC) RNA serves as an extraction and amplification control for each independently processed sample. Processed samples are amplified by RT-PCR using HCV-specific complementary primers and detected by hybridization of the amplified products to HCV- and IC-specific oligonucleotide probes. The analytical sensitivity of the test is 25 International Units (IU) of HCV per mL of pooled plasma; all HCV genotypes are detected with similar efficiency. The test detected HCV RNA 23 to 32 days prior to anti-HCV antibody seroconversion for four of the five seroconversion panels tested. The test had sufficient sensitivity to reproducibly detect a single infected unit containing 2.4 x 10(3) copies of HCV per mL in a pool with 23 uninfected units. COBAS AmpliScreen tests for HIV-1 and HBV now being validated by Roche Molecular Systems also incorporate the MultiPrep specimen processing method, thereby making it possible to use a single processed specimen to screen for all three viruses.

Genotype↗

Performance characteristics of the AmpliScreen HIV-1 test, an assay designed for screening plasma mini-pools.

This study evaluated the performance characteristics of the AmpliScreen(TM)Human Immunodeficiency Virus-Type 1 (HIV-1) Test, Version 1.5, a test designed for screening pools composed of samples from individual units of blood or plasma. HIV-1, hepatitis C (HCV) and hepatitis B (HBV) virus particles were simultaneously extracted and concentrated from plasma by a multi-prep sample processing procedure. An HIV-1 Internal Control (IC) RNA was added to each sample to serve as an extraction and amplification control. Processed samples were amplified by RT-PCR using HIV-1-specific complementary primers and detected by hybridization of the amplified products to HIV-1- and IC-specific oligonucleotide probes. The analytical sensitivity of the test (concentration that yields >/=95% positive results in a set of replicate tests) was 25 copies of HIV-1 RNA per mL of pooled plasma. Representative strains from all HIV-1 group M subtypes were reproducibly detected (>95% positive results among 22 replicate tests) at concentrations of 30 to 75 viral particles per ml. The test exhibited excellent specificity; it did not cross-react with a set of 30 viral and five bacterial isolates and yielded negative results on a panel of 500 blood samples from HIV-1 seronegative donors. Samples containing abnormally high levels of haemoglobin, albumin, triglycerides or bilirubin in plasma samples did not interfere with the detection of HIV-1 RNA at a concentration of 100 copies of per ml. The test detected HIV-1 RNA 7-17 days prior to anti-HIV-1 antibody seroconversion for all 10 seroconversion panels tested. A fully automated COBAS AmpliScreen(TM)version of this test is being validated. COBAS AmpliScreen tests for HCV and HBV also incorporate the multi-prep specimen processing method, thereby making it possible to use a single processed specimen to screen for all three viruses.

Evaluation Studies as Topic↗