Temperature field estimation using electrical impedance profiling methods. I. Reconstruction algorithm and simulated results.

Algorithmic methods for estimating complete temperature fields during hyperthermia treatments based on surface and internal electrical measurements are presented. The techniques utilized draw upon impedance imaging concepts, but rather than limit the measurements to positions on the body surface, internal impedance recording sites are allowed. Theoretical simulations show that this strategy improves the reconstructed image in the target region when either internal measurement locations are added to a given number of external recording sites or some external measurement locations are replaced by internal recording positions. The algorithms developed are tested on a set of problems with increasing levels of complexity. The culmination of these investigations is a complete simulation of a hyperthermia treatment and reconstruction of a thermal image for a body cross-section of an actual cancer patient. The results of this work suggest that the surface plus internal measurement approach holds some promise as a method for estimating temperature distributions during hyperthermia treatments. However, the simulations while promising are idealizations in that they are two-dimensional with modest levels of additive noise. In a companion paper, we explore the viability of this approach in several laboratory phantom experiments which include both static and heat-induced transient electrical property profiles.

Algorithms

Temperature field estimation using electrical impedance profiling methods. II. Experimental system description and phantom results.

An electrical impedance tomography system has been developed and tested for the purpose of thermal imaging. Since impedance changes with temperature, images of impedance subtracted from normothermic baselines will provide a map of temperature data. A system was designed to be operational at 10-50 kHz and to utilize 16 external electrodes around the periphery of a tissue-equivalent phantom encompassing the region of interest. These electrodes serve as current sources for the 5 mA constant-current inputs and are also used for reading differential voltages. Hyperthermia treatments for cancer require that internal thermometry probes be inserted into the tumour volume. Linear arrays of electrodes with thermometry tracks for micro-dimension thermometry serve this function, as well as providing localized voltage measurements in the region of interest. The embedded temperature sensors provide a quality assurance and calibration standard for the linear arrays in reconstruction of impedance profiles. Results of transient heating experiments with conductive and ultrasound heating are shown where image reconstruction is performed using a finite element model. Temperature predictions in these studies were accurate to better than 1 degree C on average when using information from surface electrodes combined with internal linear arrays. Maximum temperature errors, however, was found to be > 5 degrees C which suggests that further noise reduction during data acquisition and improvements in the reconstructions algorithms are needed.

Electric Impedance

Clinical implementation of electrical impedance tomography with hyperthermia.

We describe the use of electrical impedance tomography (EIT) for non-invasive thermal imaging in conjunction with a clinical treatment of a superficial scalp lesion utilizing a spiral microstrip antenna. This is our first reported use of EIT with a clinical hyperthermia treatment and perhaps the first world-wide. The thermal measurements recorded during treatment compare favourably with the images reconstructed from impedance data gathered during heating. A linear relation, measured in phantom material, between the change in temperature with the change in reconstructed impedance was assumed. The average discrepancy between the measured temperature changes with the temperatures reconstructed from the impedance changes was 1.4 degrees C, with the maximum being 8.9 degrees C. These preliminary data suggest that impedance changes can be measured during hyperthermia delivery and temperature estimates based on these observed changes are possible in the clinical setting. These findings also point to the complex, yet critical nature of the impedance versus temperature relationship for tissue in vivo. The reconstructed thermal images may provide complementary information about the overall thermal damage imposed during heating. Based on this initial clinical experience we feel that EIT has great potential as a viable clinical aid in imaging the temperature changes imposed during hyperthermia.

Electric Impedance