PubMed Health⌕ Search

Biomedical subjects

M K Jeong

Publications and source records attributed to M K Jeong.

2 recordsLinked to original sources

Enhancing flexible fiber filter (3FM) performance using in-line coagulation.

A new packing for deep bed filtration using Flexible Fibers has been proposed and developed on a very large scale for tertiary treatment of wastewater. The purpose of this study is to check the possibility of using this technology for the production of drinking water from surface water. In this study, the feasibility of the fiber filter application on water treatment was examined and the removal efficiency of fiber filter was improved using an in-line coagulant injection method. The experiments were carried out at pilot scale. The filter was packed with bundles of polyamide fibers with a bed porosity of 93%. Nak-dong River was used as the filter influent water and alum, PSOM, and PAC were used as the coagulants. The coagulants were injected by the in-line injection method. Small dosages (1-5 mg/L) of the polymeric coagulants (PSOM and PAC) showed an increase of removal efficiency compared to the operation without coagulants. Specifically, 1 mg/L of PAC showed the longest filtration time. Considering filtration time, filtrate quality, and filtered volume, the filtration velocity of 120 m/hr was chosen as an optimum value. For long-term operations, the effluent quality was 0.4 NTU and the removal efficiency was stable for the given optimum conditions.

Filtration↗

Realization of sinc waves in ultrasound imaging systems.

It is known that the transmit pulse waveforms of a limited-diffraction beam in a linear array transducer should be varied according to transducer element location, dictating the use of sophisticated hardware. In order to overcome this disadvantage while achieving the same field response, we propose a method of synthesizing limited-diffraction beams by combined signal processing of pulsed plane waves propagating in distinct directions over several consecutive insonification time intervals. The method is capable of achieving both higher transmit power and better lateral resolution over a larger depth of field. Although its field response is not uniform throughout the imaging points, this is not a major problem since the response is quite uniform within a region of interest. The proposed method requires the use of multiple insonifications for transmit focusing, and, therefore, can be applied in imaging slowly-moving or still objects. Both simulation and experimental results corroborate its superiority in terms of the lateral resolution at all imaging depths.

Computer Simulation↗