Enhancing flexible fiber filter (3FM) performance using in-line coagulation.

Abstract

A new packing for deep bed filtration using Flexible Fibers has been proposed and developed on a very large scale for tertiary treatment of wastewater. The purpose of this study is to check the possibility of using this technology for the production of drinking water from surface water. In this study, the feasibility of the fiber filter application on water treatment was examined and the removal efficiency of fiber filter was improved using an in-line coagulant injection method. The experiments were carried out at pilot scale. The filter was packed with bundles of polyamide fibers with a bed porosity of 93%. Nak-dong River was used as the filter influent water and alum, PSOM, and PAC were used as the coagulants. The coagulants were injected by the in-line injection method. Small dosages (1-5 mg/L) of the polymeric coagulants (PSOM and PAC) showed an increase of removal efficiency compared to the operation without coagulants. Specifically, 1 mg/L of PAC showed the longest filtration time. Considering filtration time, filtrate quality, and filtered volume, the filtration velocity of 120 m/hr was chosen as an optimum value. For long-term operations, the effluent quality was 0.4 NTU and the removal efficiency was stable for the given optimum conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J J Lee, M K Jeong, J H Im, R BenAim, S H Lee, J E Oh, H J Woo, C W Kim. 2006. Enhancing flexible fiber filter (3FM) performance using in-line coagulation.. https://doi.org/10.2166/wst.2006.329

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of filtration and pH perturbation on freshwater organic matter fluorescence.

Fluorescence of organic matter from six contrasting freshwaters was analysed after filtration (1.2 microm and 0.2 microm filter sizes) and pH perturbation (+/-2 pH units from ambient conditions). Two fluorophores were compared in detail: tryptophan-like fluorescence, whose filtration and pH characteristics are relatively poorly understood, and humic-like fluorescence, which is better characterised. Although there was some variability in both fluorophores, the tryptophan-like fluorescence showed the most significant decrease in fluorescence intensity between raw and 1.2 microm filter samples, and a much smaller decrease between 1.2 and 0.2 microm, demonstrating a significant source associated with particulate material as well as a significant <0.2 microm fraction. In contrast, humic-like fluorescence shows little change with filtration, suggesting that the majority of this fluorescence is associated with truly dissolved material. The pH perturbation experiments demonstrate that tryptophan-like fluorescence is less impacted by pH than with filter fraction. For humic-like fluorescence, pH effects are weak and are not as consistent as those reported in the literature for extracted humic substances. pH perturbation of the freshwaters shows a wide range of sample specific pH responses, significantly more variable than that observed in experiments using extracted humic substances and tryptophan standards, demonstrating the natural variability of freshwater dissolved organic matter.

Filtration↗

[Approximation of collimator scatter factor Sc by a saturation model].

To more easily estimate accurate values of collimator scatter facor, S(c), we suggest a two-component saturation model that accounts for scatter from the primary collimator and flattening filter and from the collimator jaws. This model, which assumes an exponential distribution of scatter intensity, was tested by in-air measurements using a mini-phantom for 4 MV and 10 MV X-rays of a Clinac 2100 C/D linear accelerator. The results showed a good fit of this model to our measured data (R(2)>0.9993). When the measured value was divided into the primary collimator/flattening filter component and the collimator jaw component, as expected, the former component showed a rapid and full saturation curve with increased field size, while the latter showed an almost linearly increasing curve. Therefore, we think that this saturation model is useful for the estimation of S(c) and is applicable to monitor unit calculation for an asymmetric field.

Filtration↗

Examination of beam profile measurement using an imaging plate by the light exposure fading method for quality assurance of external radiation therapy.

High-resolution film dosimetry has been used for several decades to check and to measure two-dimensional dose distributions. However, in recent years, the automatic processor has been replaced by the spread of computed radiography, or has been little used hospitals. In this study, we measured the off-center ratio (OCR) of the open field, after an irradiating radiation beam was delivered to the imaging plate (IP) under conditions in which the IP was exposed to a fixed amount of light with fading, and compared these data with the OCR measured by an ionization-chamber dosimeter, which is the standard method used for measuring radiation dose. Profile measurement using IP could be achieved by performing light fading, even at a range of more than 100 MU. Further, by using a metallic filter, we succeeded in demonstrating that the profile measurement of IP in an open irradiation field could approximate the values of those obtained by an ionization chamber dosimeter. This method can serve as a simple, easy-to-use method for evaluating the QA of dose distribution in radiation therapy.

Filtration↗