PubMed Health⌕ Search

Biomedical subjects

M Lassmann

Publications and source records attributed to M Lassmann.

18 recordsLinked to original sources

A novel thyroid phantom for ultrasound volumetry: determination of intraobserver and interobserver variability.

A novel thyroid ultrasound phantom with tissue-equivalent characteristics was designed consisting of two lobes with three lesions each. One set of lesions is manufactured with a -5 dB echo difference to the surrounding tissue, the other with -10 dB. This phantom was used as a standardized measuring object for reproducibility of two-dimensional and three-dimensional ultrasound volumetry and for an interobserver and intraobserver variability study. For the variability study, nine experienced physicians scanned all specimen three times. Each time the volumes were calculated using the ellipsoid method. A three-dimensional ultrasound scan of each specimen was performed to evaluate all volumes by multiplanar volume approximation. The results of these volume data were compared to the known true volumes. The interobserver variability ranged from -13.4% to 11.9% (median, 0.7%); the intraobserver variability from -9.1% to 16.4% (median, 3.6%). The systematic error as calculated from the total mean of all specimens is 0.5% for the interobserver variability and 4.1% for the intraobserver variability. The phantom can be used for training purposes, to improve the skills of the examining physicians by simulating real thyroid morphology, to provide a standardized reference object for long-term quality control of conventional ultrasound scanners, and the determination of the accuracy and reproducibility of volumetry using three-dimensional ultrasound systems.

Algorithms↗

[Radiation exposure in (90)Y-Zevalin therapy: results of a prospective multicentre trial].

UNLABELLED: AIM of this study was the assessment of the radiation exposure from preparation and application of (90)Y-Zevalin, the measurement of the dose rate at the patient, the exposure of family members as well as the determination of the activity concentration in urine of patients. METHODS: Overall data from 31 therapeutic administrations carried out in four institutions were evaluated. During preparation and application of (90)Y-Zevalin the finger exposures of radiochemists, technicians, and physicians were measured. The dose rate of the patient was measured immediately after radioimmunotherapy. In patients treated in a nuclear medicine therapy unit, urine was collected over a two day period and the corresponding activity was determined. Family members of outpatients were asked to wear a dosimeter over a seven day period. RESULTS: During the preparation we found a maximum skin dose of 6 mSv at the average, and during application of 3 mSv, respectively. After administration of (90)Y the dose rate was 0.4 +/- 0.1 microSv/h at 2 m distance. Urine measurements yielded a cumulated 24 h excretion of 3.9 +/- 1.4% and 4.4 +/- 1.4% within 48 h, respectively, that is equivalent to 43 +/- 18 and 50 +/- 20 MBq of (90)Y, respectively. Family members received a radiation exposure of 40 +/- 14 microSv over seven days. CONCLUSION: During preparation and application of (90)Y-Zevalin appropriate radiation shielding is necessary. For family members as well as nursing staff no additional special radiation protection measures beyond those being common for other nuclear medicine procedures are necessary.

Antibodies, Monoclonal↗

Radioiodine ablation of thyroid remnants after preparation with recombinant human thyrotropin in differentiated thyroid carcinoma: results of an international, randomized, controlled study.

CONTEXT: After surgery for differentiated thyroid carcinoma, many patients are treated with radioiodine to ablate remnant thyroid tissue. This procedure has been performed with the patient in the hypothyroid state to promote endogenous TSH stimulation and is often associated with hypothyroid symptoms and impaired quality of life. OBJECTIVE AND INTERVENTION: This international, randomized, controlled, multicenter trial aimed to compare the efficacy and safety of recombinant human TSH (rhTSH) to prepare euthyroid patients on L-thyroxine therapy (euthyroid group) to ablate remnant thyroid tissue with 3.7 GBq (100 mCi) 131I, compared with that with conventional remnant ablation performed in the hypothyroid state (hypothyroid group). Quality of life was determined at the time of randomization and ablation. After the administration of the 131-I dose, the rate of radiation clearance from blood, thyroid remnant, and whole body was measured. RESULTS: The predefined primary criterion for successful ablation was "no visible uptake in the thyroid bed, or if visible, fractional uptake less than 0.1%" on neck scans performed 8 months after therapy and was satisfied in 100% of patients in both groups. A secondary criterion for ablation, an rhTSH-stimulated serum thyroglobulin concentration less than 2 ng/ml, was fulfilled by 23 of 24 (96%) euthyroid patients and 18 of 21 (86%) hypothyroid patients (P = 0.2341). Quality of life was well preserved in the euthyroid group, compared with the hypothyroid group, as demonstrated by their lower pretreatment scores on the Billewicz scale for hypothyroid signs and symptoms, 27 +/- 7 vs. 18 +/- 4 (P < 0.0001) and their significantly higher Short Form-36 Health Assessment Scale scores in five of eight categories. Euthyroid patients had a statistically significant one third lower radiation dose to the blood, compared with patients in the hypothyroid group. CONCLUSIONS: This study demonstrates comparable remnant ablation rates in patients prepared for 131I remnant ablation with 3.7 GBq by either administering rhTSH or withholding thyroid hormone. rhTSH-prepared patients maintained a higher quality of life and received less radiation exposure to the blood.

Adolescent↗

EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

The European procedural guidelines for radionuclide imaging of myocardial perfusion and viability are presented in 13 sections covering patient information, radiopharmaceuticals, injected activities and dosimetry, stress tests, imaging protocols and acquisition, quality control and reconstruction methods, gated studies and attenuation-scatter compensation, data analysis, reports and image display, and positron emission tomography. If the specific recommendations given could not be based on evidence from original, scientific studies, we tried to express this state-of-art. The guidelines are designed to assist in the practice of performing, interpreting and reporting myocardial perfusion SPET. The guidelines do not discuss clinical indications, benefits or drawbacks of radionuclide myocardial imaging compared to non-nuclear techniques, nor do they cover cost benefit or cost effectiveness.

Cardiology↗

[Monitoring of 131I incorporation in nuclear medicine personnel by self accomplished measurements].

AIM: The personnel in nuclear medicine therapy wards must be monitored according to German guidelines for incorporations of (131)I. A surveillance with the employees measuring themselves similarly to the autonomous contamination survey using hand-foot-clothing monitors is presented as an alternative to the monitoring according to the official guidelines. METHOD: The employees use a dedicated device to measure themselves every working day. The automatic individual positioning of the device ensures reliable and reproducible results. The thyroid dose is determined from the measured time activity curve. The individual values of depth and mass of the thyroid are taken into account for activity measurement and dose evaluation, respectively. RESULTS: The employees measure themselves regularly and utilize the device to check for activities in the thyroid at an early stage after suspected incorporation. The almost complete surveillance permits a dosimetry with slight uncertainty. The determined thyroid doses of all monitored persons average to 0.35 mSv per month. CONCLUSION: The incorporation surveillance by autonomous monitoring allows a more reliable and more precise dosimetry than the monitoring according to the official guidelines. Despite numerous measurements the practice saves time and money as a result of the automation.

Guidelines as Topic↗

[Procedure guideline for radioiodine test (version 2)].

The version 2 of the procedure guideline for radioiodine test is an update of the guideline published in 1999. The following statements were added or modified: The procedure guideline discusses the pros and cons of a single measurement or of repeated measurements of the iodine-131 uptake and their optimal timing. Different formulas are described when one, two or three values of the radioiodine kinetic are available. The probe with a sodium iodide crystal, alternative or additionally the gamma-camera using the ROI-technique are instrumentations for the measurement of iodine-131 uptake. A possible source of error is an inappropriate measurement (sonography) of the target volume. The patients' preparation includes the withdrawal of antithyroid drugs 2-3 days before radioiodine administration. The patient has to avoid iodine-containing medication and the possibility of additives of iodide in vitamin- or electrolyte-supplementation has to be considered.

Documentation↗

[Aa DICOM based PACS for nuclear medicine].

The installation of a Radiology Information System (RIS) connected to a Hospital Information System (HIS) and a Picture Archiving and Communications System (PACS) seems mandatory for a nuclear medicine department in order to guarantee a high patient throughput. With these systems a fast transmission of reports, images to the in- and out-patients' wards and private practitioners is realized. Therefore, since April 2000, at the department of nuclear medicine of the university of Würzburg a completely DICOM based PACS has been implemented in addition to the RIS. With this system a DICOM based workflow is realized throughout the department of nuclear medicine for reporting and archiving. The PACS is connected to six gamma-cameras, a PET scanner, a bone densitometry system and an ultrasound device. The volume of image data archived per month is 4 GByte. Patient demographics are provided to the modalities via DICOM-Worklist. With these PACS components a department specific archive purely based on DICOM can be realized. During the installation process problems occurred mainly because of the complex DICOM standard for nuclear medicine. Related to that is the problem that most of the software implementations still contain bugs or are not adopted to the needs of a nuclear medicine department (particularly for PET). A communication software for the distribution of nuclear medicine reports and images based on techniques used for the worldwide web is currently tested.

Diagnostic Imaging↗

The use of three-dimensional ultrasound for thyroid volumetry.

Conventional two-dimensional (2-D) ultrasound is the standard method for the investigation of thyroid morphology. Volume calculations need model assumptions and are observer dependent. The present study performed with a commercially available three-dimensional (3-D) system Freescan added to a conventional ultrasound scanner compares the accuracy of conventional thyroid volumetry to several methods of 3-D volume determination. In vitro measurements were performed on thyroid phantoms with known volumes. The standard deviation of the normalized differences was 8.0% (3-D segmentation) and 10.5% (conventional). For the accuracy of volume determination in human thyroids we performed a postmortem study. The thyroid volume was calculated conventionally by the ellipsoid model and by two 3-D methods (segmentation and the newly developed multiplanar volume approximation). The reference volume was determined after resection by submersion. The standard deviation of the normalized differences was 26.9% for the conventional method, 9.7% for 3-D segmentation and 11.5% for the multiplanar volume approximation, showing significant better results for both 3-D methods and no significant difference between the 3-D methods. The 3-D system, therefore, achieves a better accuracy for thyroid volumetry than the conventional volumetry using planar images. In addition, the 3-D images are stored electronically and can be used for follow-up studies.

Cadaver↗

Track structures and dose distributions from decays of (131)I and (125)I in and around water spheres simulating micrometastases of differentiated thyroid cancer.

The disintegration of the radionuclides (131)I and (125)I and the subsequent charged-particle tracks left behind in water (as a model substance for a biological cell) are simulated by the Monte Carlo track structure simulation code PARTRAC, using new inelastic electron scattering cross sections for condensed water. Every photon and electron emitted was followed in detail, event by event, down to 10 eV. From the spatial information on the track structures, absorbed dose distributions per (131)I and (125)I decay were calculated in and around water spheres simulating micrometastases as well as in the tissue surrounding such metastases. These radionuclides were assumed to be distributed uniformly inside spheres of different diameters (0.01, 0.03, 0.1, 0.3, 1.0 and 3.0 mm). The respective electron degradation spectra, the nearest-neighbor distance distributions between inelastic events, and the distance distributions for all activations for both iodine radionuclides were calculated. The absorbed fractions of the initial electron energies, absorbed doses and energy depositions, and single-event distributions, F(1)(epsilon), inside the six water spheres described above and in the surrounding tissue were also calculated. The absorbed doses per decay inside the six water spheres, i.e., the calculated S values (listed from 0.01 to 3.0 mm), were 6.8 x 10(-4), 7.2 x 10(-5), 5.5 x 10(-6), 4.9 x 10(-7), 3.1 x 10(-8) and 1.8 x 10(-9) Gy Bq(-1) s(-1) for (131)I, and 3.4 x 10(-3), 1.7 x 10(-4), 5.1 x 10(-6), 2.0 x 10(-7), 5.6 x 10(-9) and 2.2 x 10(-10) Gy Bq(-1) s(-1) for (125)I. It is concluded that, in the treatment of thyroid cancer, the geometrical track structure properties of (125)I might be superior to those of (131)I in micrometastases with diameters less than 0.1 mm; however, in this medical context, many other factors also have to be considered.

Humans↗

Use of recombinant human thyrotropin before radioiodine therapy in patients with advanced differentiated thyroid carcinoma.

The use of 131I for radioablative therapy in patients with differentiated thyroid cancer (DTC) requires a sufficient serum concentration of TSH for efficient thyroid tissue uptake of iodine. We describe the use of recombinant human TSH (rhTSH) in conjunction with ablative radioiodine therapy (RIT) in 11 patients (16 total treatments) with advanced and/or recurrent DTC (5 papillary, 6 follicular) for whom withdrawal of thyroid hormone suppression therapy (THST), the standard method to increase serum TSH, was not an option. Indications for rhTSH use in these patients included inability to tolerate withdrawal of thyroid hormones due to very poor physical condition or inability to achieve sufficient serum TSH levels after THST withdrawal. Ten patients had undergone thyroidectomy, and most (9 of 11) had received prior ablative RIT after THST withdrawal. Baseline thyroglobulin levels ranged from 25 to nearly 30,000 ng/mL, reflecting the heterogeneity of the patient population. In 7 cases (5 patients), posttherapy thyroglobulin levels assessed at a mean of 4.3 months (range, 2-10 months) after 131I therapy were decreased by at least 30% compared to pretherapy levels. In follow-up visits, an additional 3 patients showed marked clinical improvement or decreased or stabilized tumor burden in whole body scans compared to pretherapy scans. Three patients died of progressive disease within 2 months of therapy before follow-up assessments occurred. No adverse events were reported among the 8 surviving patients. The results suggest that rhTSH offers a promising alternative to THST withdrawal to allow ablative RIT after effective TSH stimulation in patients with advanced recurrent DTC who would not otherwise be able to receive this treatment. This therapeutic indication extends the clinical potential of this new agent, already demonstrated to be effective for use with 131I for diagnostic purposes.

Adenocarcinoma, Follicular↗

Clinical experience with recombinant human thyroid-stimulating hormone (rhTSH): whole-body scanning with iodine-131.

Whole-body scanning (WBS) with iodine-131 (I-131) is currently used together with serum thyroglobulin (Tg) measurement in the diagnostic follow-up of well-differentiated thyroid carcinoma. One of the main disadvantages of I-131 WBS is its requirement of repeated weeks-long withdrawal of thyroid hormone suppression therapy (THST) to raise endogenous thyroid-stimulating hormone (TSH) production. This results in hypothyroidism and associated abnormalities, discomfort and morbidity. Recently, however, a series of multicentre clinical studies established the efficacy, safety, non-antigenicity, and quality of life benefits of recombinant human TSH (rhTSH, Thyrogen, thyrotropin alfa, Genzyme Corporation, Cambridge, MA, USA) in promoting radioiodine uptake and permitting sensitive I-131 WBS in patients on THST after initial therapy of well-differentiated thyroid cancer. Thus in everyday practice, rhTSH administration may in many cases supersede THST withdrawal as a preparative method for I-131 imaging. With the use of rhTSH, as whenever I-131 WBS is performed, useful and accurate imaging requires meticulous attention to good scanning practices. These include use of appropriate equipment, proper timing, sufficient scanning time, vigilance against artifacts and iodine contamination, and consideration of additional imaging in the case of ambiguous 48-hour scans. Whole-body retention of I-131 is approximately 50% greater during hypothyroidism after THST withdrawal than during euthyroidism on THST and rhTSH. Therefore, it is important to use an adequate diagnostic activity of > or =4 mCi (148 MBq) to compensate for the faster radioiodine clearance in the euthyroid state permitted by rhTSH administration. Ongoing dosimetric research eventually may provide more specific guidance regarding radioiodine activities for diagnostic, and, particularly, therapeutic purposes, with the use of rhTSH.

Clinical Trials, Phase II as Topic↗

X-ray fluorescence analysis (XFA) of thyroidal iodine content (TIC) with an improved measuring system.

X-ray fluorescence analysis is based on the principal that the electron structure of stable iodine in the thyroid is excited by Americium-241 gamma rays to emit a characteristic fluorescence radiation which is proportional to the amount of iodine present in the gland. A stationary measuring system consisting of a 11.1 GBq Am-241 source and a high-purity Germanium detector with spectrum analyser has been improved by a PC guided method for sonographic definition of the measuring volume. The lower limit of detectibility of the system corresponds to 0.01 mg of Iodine per ml of thyroid volume; the in vivo precision given as coefficient of variation amounts to 15%. The thyroid is exposed with a radiation dose of 6 microSv per measurement. First studies with this improved system carried out in 50 female volunteers between 20 and 40 years of age with normal thyroid volumes resulted in a mean iodine concentration of the thyroid of 0.665 +/- 0.304 mg/ml. The mean iodine excretion in urine was normal with 10.8 +/- 10.4 microg/dl.

Adult↗

[Measurement of incorporation in family members of radioiodine therapy patients after therapy of benign thyroid diseases].

AIM: Patients exhale I-131 after radioiodine therapy. In this study we quantify the amount of radioactivity and resulting thyroid doses found in people living in close contact to patients treated with I-131 after their release from a therapy ward. METHODS: For 31 relatives of 25 patients treated with I-131 the incorporation was monitored using the thyroid probe of a whole body counter. These values are used for a determination of thyroid doses. RESULTS: 11 of the 31 monitored persons had a thyroid activity of less than the minimal detectable activity of 13 Bq. The mean value of the remaining 20 people was 104 Bq in the thyroid resulting in a mean thyroid dose of 0.2 mSv (Maximum: 2 mSv). CONCLUSION: The intake of I-131 for persons in close contact to patients after dismissal from a therapy ward is low. In no case an effective dose exceeding 1 mSv was observed.

Adolescent↗

Effect of specific activity on cardiac uptake of iodine-123-MIBG.

UNLABELLED: Radioiodinated meta-iodobenzylguanidine (MIBG), an analog of norepinephrine, has been used to assess myocardial sympathetic innervation. Recent in vivo studies predict enhanced cardiac uptake of this radiopharmaceutical with high specific activity. METHODS: To clarify the effect of specific activity on cardiac uptake of radioiodinated MIBG, the distribution and kinetics of no-carrier-added [123I]MIBG (> or = 7.4 TBq/mumol) were compared with those of commercial [123I]MIBG (approximately 74 MBq/mumol) in three healthy volunteers by serial imaging and blood sampling. RESULTS: Higher specific activity result in higher uptake of radioiodinated MIBG in all volunteers in the heart (p < 0.05) and liver (p < 0.05) but not in the lung (p = 0.26). Due to rapid deiodination, a more pronounced accumulation of radioactivity was present in plasma after no-carrier-added MIBG than commercial [123I]MIBG, resulting in higher background and thyroid activity after administration of the former. Calculated heart-to-liver (p = 0.96) and heart-to-lung (p = 0.42) count ratios in all volunteers revealed no significant improvement in cardiac imaging with no-carrier-added [123I]MIBG compared to commercial [123I]MIBG. CONCLUSION: This study highlights the appreciably higher in vivo deiodination of no-carrier-added [123I]MIBG compared to commercial preparation of [123I]MIBG in humans. Cardiac images acquired with no-carrier-added [123I]MIBG do not seem to be superior to those obtained with commercial MIBG.

3-Iodobenzylguanidine↗

The use of recombinant human TSH in a patient with metastatic follicular carcinoma and insufficient endogenous TSH production.

We present a case of a patient suffering from metastatic differentiated thyroid carcinoma (DTC) and insufficient endogenous TSH production suspicious of secondary hypothyroidism. The use of recombinant human TSH (rhTSH) enabled us to administer a therapeutic activity of radioactive iodine (RAI) under maximal TSH-stimulation, achieving a marked decrease in thyroglobulin accompanied by a clinical improvement.

Adenocarcinoma, Follicular↗