The version 2 of the procedure guideline for radioiodine test is an update of the guideline published in 1999. The following statements were added or modified: The procedure guideline discusses the pros and cons of a single measurement or of repeated measurements of the iodine-131 uptake and their optimal timing. Different formulas are described when one, two or three values of the radioiodine kinetic are available. The probe with a sodium iodide crystal, alternative or additionally the gamma-camera using the ROI-technique are instrumentations for the measurement of iodine-131 uptake. A possible source of error is an inappropriate measurement (sonography) of the target volume. The patients' preparation includes the withdrawal of antithyroid drugs 2-3 days before radioiodine administration. The patient has to avoid iodine-containing medication and the possibility of additives of iodide in vitamin- or electrolyte-supplementation has to be considered.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Dietlein, J Dressler, W Eschner, M Lassmann, B Leisner, C Reiners, H Schicha, Deutsche Gesellschaft für Nuklear Medizin, Deutsche Gesellschaft für Medizinische Physik. 2003. [Procedure guideline for radioiodine test (version 2)].. https://pubmed.ncbi.nlm.nih.gov/12802475/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Retained foreign bodies from the view of the OR nurse].

Patient safety in the operating room is of high priority for the surgical team and for all healthcare workers involved. Counting procedures contribute to minimizing potential risks for the patients, especially in preventing them from leaving the operating room with retained, unintended foreign bodies. A total of 64% of operating room nurses involved in a survey are reported as having been involved in a surgical procedure in which the correct count prevented foreign bodies from being left in the patient. In addition, the strengths and potential weak points of the counting procedures could be identified. The results of the survey and drafts for a standard counting control as well as procedural recommendations are presented for discussion. A recommendation can be provided for each surgical department in order to check their own counting methods for avoiding potential risks.

Documentation↗