With the reflectance meter Reflolux S (Accucheck III) high as well as low blood glucose levels can be determined with excellent precision irrespective of the sample's hematocrit value. Within the range from 20-50 mg/dl we found an average deviation from the expected value of less than 2 mg/dl; in selected samples, however, a difference of up to 10 mg/dl was recorded. The scatter can be explained by the influence of hematocrit values on the results. An increase of 10% in hematocrit lowered the measured glucose value by approximately 10%. At glucose concentrations below 40 mg/dl and in the presence of high resp. low hematocrit values any results obtained with this glucose meter will only have screening character; they should be re-run using an established method.
Non-immunologic hydrops fetalis-a review of 31 cases: 31 Patients with non-immunologic hydrops fetalis (NIHF) seen between 1984 and 1987 are described. 13 infants survived. The infants with major congenital malformations and connatal infections died. In 8 of the patients who died a cause for NIHF could not be identified. 10 of the survivors presented chylous ascites and/or chylothorax without major congenital anomalies. 2 infants had fetal tachyarrhythmia and 1 patient showed severe anemia due to fetomaternal hemorrhage.
The determination of bilirubin in serum was performed by the 2.5-dichlorphenyldiazonium method (DPD) and in capillary plasma by the direct photometric method (DPM). Both methods showed a good precision and accuracy. The investigation was carried out in 135 samples with a bilirubin concentration up to 25 mg/dl. The comparison of the two methods in 62 samples with a bilirubin concentration up to 10 mg/dl showed a correlation coefficient of r = 0.862 and in 73 samples with a bilirubin concentration between 10 and 25 mg/dl a correlation coefficient of r = 0.893. In 29 cases (21.5%) we found differences between the two methods of 1.5-4.0 mg/dl. Most of them were in the critical higher range. Discussion of the DPD and DPM methods.
Four portable analyzers, HemoCue B-Glucose (I), Accu-Check III (II), One-touch II (III), and Glucometer Elite (IV), with different measuring principles were tested for their suitability for measuring blood glucose in neonates. Precision of all instruments is satisfactory. In the analysis of capillary blood from newborns, two instruments show an excellent accuracy; however, the scatter of the results for instrument (II) is about 1.6 times greater than for instrument (I). The inaccuracy of instruments (III) and (IV) is not acceptable from a clinical point of view. All devices show an influence of hematocrit, the magnitude of which varies between 5% (I) and 12% (III) for every 10% change of hematocrit. Instruments II and IV show that temperature has a marked influence on the readings; the same is true for oxygen in instrument IV. In conclusion, only instrument (I) has met the requirements of accurate and precise blood glucose determinations in neonates.
In 2018 consecutive newborn ultrasound examination of the hip was performed according to the method of Graf within the first 14 days of life (average 4th day). Typ IIa was seen as normal in newborn child. Birth weight was classified according to standards of Lubchenco and Hohenauer. Newborn with high birth weight (LGA) revealed an incidence of CDH (Typ IIc according to Graf or worse) nearly twice as high as in normal weighted newborn (AGA) (6.11% vs 3.51% [Lubchenco] and 7.95 vs 3.09 [Hohenauer]). Even in children with birth weight between 75th and 90th percentile we found a CDH incidence of 5.54%. Ultrasound examination of the hip is suggested in newborn children with high birth weight because of a higher risk for development of a CDH. Other risk-factors like breech position or of CDH.