PubMed HealthSearch

Biomedical subjects

M Pompesius-Kempa

Publications and source records attributed to M Pompesius-Kempa.

3 recordsLinked to original sources

Trabecular bone pattern factor--a new parameter for simple quantification of bone microarchitecture.

The stability of trabecular bone depends not only on the amount of bone tissue, but also on the three-dimensional orientation and connectedness of trabeculae, which is summarized as trabecular microarchitecture. In previous studies we could demonstrate that in three-dimensional bone tissue the relation of trabecular plates to rods is reflected in the ratio of concave to convex surfaces of the bone pattern in two-dimensional bone sections. For the quantification of the connectedness of these bone patterns we developed a new histomorphometric parameter called Trabecular Bone Pattern factor (TBPf). The basic idea is that the connectedness of structures can be described by the relation of convex to concave surfaces. A lot of concave surfaces represent a well connected spongy lattice, whereas a lot of convex surfaces indicate a badly connected trabecular lattice in two-dimensional sections. By means of an automatic image analysis system we measure trabecular bone area (A1) and perimeter (P1). A second measurement of these two parameters (now A2 and P2) is done after a simulated dilatation of trabeculae on the screen. This dilatation results in a characteristic change of bone area and perimeter depending on the relation of convex to concave surfaces. TBPf is defined as a quotient of the difference of the first and the second measurement: TBPf = (P1 - P2)/(A1 - A2). First measurements of TBPf in 192 iliac crest bone biopsies of autopsy cases show that there is not only age-related loss of bone volume, but also a decrease of trabecular connectedness. By means of TBPf we can demonstrate a significant difference in the age-related loss of trabecular connectivity between male and female individuals.

Autoanalysis

[Bone structure changes in hip joint endoprosthesis implantation over the course of many years. A quantitative study].

The stability of implanted artificial joints is limited. One main factor for this is the change of the bone tissue near the implant. Therefore we studied femura with stem endoprostheses derived from autopsy. All specimens were cut in horizontal and longitudinal sections. X-rays were made of all sections. Then the specimens were embedded undecalcified and ground to 10 microns. The wellknown phenomenons at the bone cement border were found too. Direct bone cement contact is about 5%. The 4 studied femura show a higher porosity of cortical bone as controls. The loss of cortical bone is up to 40% after 55 months. There is a correlation between new load situation and the localisation of bone loss.

Aged