PubMed HealthSearch

PubMed · 1389573

Trabecular bone pattern factor--a new parameter for simple quantification of bone microarchitecture.

Abstract

The stability of trabecular bone depends not only on the amount of bone tissue, but also on the three-dimensional orientation and connectedness of trabeculae, which is summarized as trabecular microarchitecture. In previous studies we could demonstrate that in three-dimensional bone tissue the relation of trabecular plates to rods is reflected in the ratio of concave to convex surfaces of the bone pattern in two-dimensional bone sections. For the quantification of the connectedness of these bone patterns we developed a new histomorphometric parameter called Trabecular Bone Pattern factor (TBPf). The basic idea is that the connectedness of structures can be described by the relation of convex to concave surfaces. A lot of concave surfaces represent a well connected spongy lattice, whereas a lot of convex surfaces indicate a badly connected trabecular lattice in two-dimensional sections. By means of an automatic image analysis system we measure trabecular bone area (A1) and perimeter (P1). A second measurement of these two parameters (now A2 and P2) is done after a simulated dilatation of trabeculae on the screen. This dilatation results in a characteristic change of bone area and perimeter depending on the relation of convex to concave surfaces. TBPf is defined as a quotient of the difference of the first and the second measurement: TBPf = (P1 - P2)/(A1 - A2). First measurements of TBPf in 192 iliac crest bone biopsies of autopsy cases show that there is not only age-related loss of bone volume, but also a decrease of trabecular connectedness. By means of TBPf we can demonstrate a significant difference in the age-related loss of trabecular connectivity between male and female individuals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Hahn, M Vogel, M Pompesius-Kempa, G Delling. 1992. Trabecular bone pattern factor--a new parameter for simple quantification of bone microarchitecture.. https://doi.org/10.1016/8756-3282(92)90078-b

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Significance of the automated blood count].

Modern hematology depends on rapid and accurate determination of quantitative and qualitative blood counts. Fully automated analyzers based on the principles of flow cytometry have replaced the traditional blood smear in the routine laboratory. They count the number of red cells, platelets and leukocytes with high precision. In addition, they divide the cells into different populations according to their physical or chemical properties. This population distribution pattern mimics a "differential" blood smear. Normality can be assessed with a high degree of accuracy, rapidly and reproducibly. The qualitative changes frequently provide pointers to the final diagnosis. In case of abnormalities the reports are flagged. A microscopic analysis should be added according to internal laboratory guidelines. It clarifies pathological findings and is essential in the search for specific abnormalities such as malaria. This underlines the need for exchange of information between physician and laboratory.

Autoanalysis

Fast liquid chromatography for the determination of drugs in plasma and combination with liquid-solid extraction in a fully automated system.

Fast liquid chromatography was applied to the assay of several drugs in plasma. Short columns, 3.3-4 cm long, packed with C18 material, 3 microns particle size, were used. The peaks were little subject to extra-column band-broadening because the investigated drugs were eluted with high capacity factors in order to obtain an adequate separation from plasma components. The main influences on efficiency were the response time of the detector and the solvent composition of the injected sample. Conventional apparatus was used. A fully automated analytical system combining liquid-solid extraction via disposable extraction columns and fast liquid chromatography on a small-dimensioned 3 microns particle size column is described for the assay of drugs in plasma. Automation was accomplished by using the Automatic Sample Preparation with Extraction Columns system.

Autoanalysis