PubMed Health⌕ Search

Biomedical subjects

M Puderbach

Publications and source records attributed to M Puderbach.

9 recordsLinked to original sources

[MRI in mucoviscidosis (cystic fibrosis)].

Cystic fibrosis (CF) is a multi-systemic disease with major impact on the lungs. Pulmonary manifestation is crucial for the prognosis and life expectancy of patients. Imaging modalities and lung function tests reflect the pulmonary status in these patients. The standard imaging modality for diagnosis and follow-up of pulmonary changes is chest x-ray. The gold standard for the detection of parenchymal lung changes remains high resolution computed tomography (HRCT), but this is not used routinely for CF-patients due to radiation exposure. Magnetic resonance imaging (MRI) used to be of no importance in monitoring cystic fibrosis lung disease, as shown in studies from the 1980s and early 1990 s. The continuing improvement of MRI techniques, however, has allowed for an adequate application of this non-radiation method in diagnosing the major pulmonary findings in CF, in addition to the assessment of lung function.

Cystic Fibrosis↗

Reproducible Simulation of Respiratory Motion in Porcine Lung Explants.

PURPOSE: To develop a model for exactly reproducible respiration motion simulations of animal lung explants inside an MR-compatible chest phantom. MATERIALS AND METHODS: The materials included a piston pump and a flexible silicone reconstruction of a porcine diaphragm and were used in combination with an established MR-compatible chest phantom for porcine heart-lung preparations. The rhythmic inflation and deflation of the diaphragm at the bottom of the artificial thorax with water (1 - 1.5 L) induced lung tissue displacement resembling diaphragmatic breathing. This system was tested on five porcine heart-lung preparations using 1.5T MRI with transverse and coronal 3D-GRE (TR/TE = 3.63/1.58, 256 x 256 matrix, 350 mm FOV, 4 mm slices) and half Fourier T2-FSE (TR/TE = 545/29, 256 x 192, 350 mm, 6 mm) as well as multiple row detector CT (16 x 1 mm collimation, pitch 1.5, FOV 400 mm, 120 mAs) acquired at five fixed inspiration levels. Dynamic CT scans and coronal MRI with dynamic 2D-GRE and 2D-SS-GRE sequences (image frequencies of 10/sec and 3/sec, respectively) were acquired during continuous "breathing" (7/minute). The position of the piston pump was visually correlated with the respiratory motion visible through the transparent wall of the phantom and with dynamic displays of CT and MR images. An elastic body splines analysis of the respiratory motion was performed using CT data. RESULTS: Visual evaluation of MRI and CT showed three-dimensional movement of the lung tissue throughout the respiration cycle. Local tissue displacement inside the lung explants was documented with motion maps calculated from CT. The maximum displacement at the top of the diaphragm (mean 26.26 [SD 1.9] mm on CT and 27.16 [SD 1.5] mm on MRI, respectively [p = 0.25; Wilcoxon test]) was in the range of tidal breathing in human patients. CONCLUSION: The chest phantom with a diaphragmatic pump is a promising platform for multi-modality imaging studies of the effects of respiratory lung motion.

Animals↗

Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences.

The aim of this study was to evaluate the image quality of time-resolved echo-shared parallel MRA of the lung. The pulmonary vasculature of nine patients (seven females, two males; median age: 44 years) with pulmonary disease was examined using a time-resolved MRA sequence combining echo sharing with parallel imaging (time-resolved echo-shared angiography technique, or TREAT). The sharpness of the vessel borders, conspicuousness of peripheral lung vessels, artifact level, and overall image quality of TREAT was assessed independently by four readers in a side-by-side comparison with non-echo-shared time-resolved parallel MRA data (pMRA) previously acquired in the same patients. Furthermore, the SNR of pulmonary arteries (PA) and veins (PV) achieved with both pulse sequences was compared. The mean voxel size of TREAT MRA was decreased by 24% compared with the non-echo-shared MRA. Regarding the sharpness of the vessel borders, conspicuousness of peripheral lung vessels, and overall image quality the TREAT sequence was rated superior in 75-76% of all cases. If the TREAT images were preferred over the pMRA images, the advantage was rated as major in 61-71% of all cases. The level of artifacts was not increased with the TREAT sequence. The mean interobserver agreement for all categories ranged between fair (artifact level) and good (overall image quality). The maximum SNR of TREAT did not differ from non-echo-shared parallel MRA (PA: TREAT: 273+/-45; pMRA: 280+/-71; PV: TREAT: 273+/-33; pMRA: 258+/-62). TREAT achieves a higher spatial resolution than non-echo-shared parallel MRA which is also perceived as an improved image quality.

Adolescent↗

Quantitative analysis of lung and tumour mobility: comparison of two time-resolved MRI sequences.

The purpose of this study was to describe the use of parallel imaging technique (PAT) using dynamic MRI in lung and tumour mobility during the breathing cycle. 20 patients with stage I non-small cell lung carcinoma were investigated using two dynamic gradient echo sequences with PAT (TrueFISP (fast imaging with steady precession), and fast low angle shot (FLASH). Craniocaudal distance from the apex to the diaphragm of the thorax and tumour mobility during the breathing cycle were measured. Signal-to-noise ratio (SNR) of the tumour was determined. In spite of the different temporal resolutions both trueFISP and FLASH sequence proved to be adequate to continuously measure lung motion and tumour mobility. SNR of the tumour was significantly higher using the trueFISP sequence than FLASH sequence (20.7+/-3.6 vs 5.8+/-2.3, p<0.01). Mobility of the tumour bearing hemithorax was significantly lower compared with the non-tumour bearing hemithorax (p<0.05). Dynamic MRI using PAT allows for continuous quantitative documentation of tumour mobility and lung motion. Because of the higher SNR, trueFISP sequence provides a better delineation of intrapulmonary lesions with a sufficient temporal resolution.

Aged↗

[Contrast-enhanced 3D MR perfusion of the lung: application of parallel imaging technique in healthy subjects].

PURPOSE: Evaluation of lung perfusion by contrast-enhanced 3D MRI using partial parallel imaging techniques. MATERIALS AND METHODS: Eight healthy volunteers were examined using a contrast-enhanced dynamic FLASH 3D sequence with partial parallel imaging technique at 1.5 T MRI with a TA of 1.5 sec. The whole lung was covered by 36 coronal slices. A ventral, middle and dorsal slice of each lung was manually segmented and signal-to-time curves were computed. For absolute quantification of blood flow through the right and left pulmonary artery, phase-contrast flow measurements were performed. RESULTS: No significant difference was found between the signal intensity in the right (8.9 +/- 2.6) and left (8.0 +/- 3.5) lung, corresponding to a left-to-right signal intensity ratio of 0.9. A significantly higher signal intensity was found in the dorsal regions of the lungs (p = 0.01) compared to the ventral regions. The time to peak of the signal intensity was significantly shorter in the dorsal (15.3 sec) and middle (15.7 sec) regions of the lungs (p = 0.03 and p = 0.04, respectively) than in the ventral regions (16.3 sec). The ratio between blood flow through the left (2.2 L/min) and right (2.7 L/min) lung was 0.84. CONCLUSION: Partial parallel image acquisition can assess the perfusion of the lungs at high temporal resolution. The perfusion is slightly higher on the right than on the left. The signal increases faster and has a higher peak in the dorsal lung regions.

Adolescent↗

Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results.

PURPOSE: To assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. MATERIALS AND METHODS: Eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 degrees; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. RESULTS: Patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or Eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104 - 322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). CONCLUSION: Time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease.

Acute Disease↗

3He-MRI-based vs. conventional determination of lung volumes in patients after unilateral lung transplantation: a new approach to regional spirometry.

BACKGROUND: To use 3Helium (3He)-MRI in patients with unilateral lung grafts to assess the contributions of graft and native lung to total ventilated lung volume, and second to compare conventional measurements of intrapulmonary gas volume (spirometry, body plethysmography) with image-based volumetry of ventilated lung parenchyma visualized by hyperpolarized 3He-MRI. METHODS: With Ethics Committee approval, five patients with single lung transplantation (SLTX) for idiopathic pulmonary fibrosis (IPF) underwent both conventional pulmonary function testing (PFT) and 3He-MRI of the lung. Intrapulmonary gas volume (GV) during the inspiratory breathhold for 3He-MRI was calculated from measured functional residual capacity (corrected for supine position) and inspired tidal volume. Image-based global and regional lung volumetries (LV) were performed in three-dimensionally reconstructed 3He-MR images (corrected for the fraction of tissue and blood). RESULTS: Transplanted lungs were characterized by a homogeneous distribution of signal intensity, whereas the native lungs of the patients suffering from IPF displayed an inhomogeneous signal distribution pattern with numerous round or wedge-shaped ventilation defects. Total ventilated lung volume determined by 3He-MRI correlated well with PFT-based measurements, but with a systematic overestimation of the 3He-based lung volumetry of approximately 20%. Functioning lung grafts contributed 66+/-6% and their corresponding native IPF lungs 34+/-6% to total ventilated volume (P<0.05; mean+/-SD). CONCLUSION: 3Helium-MRI of the lung offers a novel approach to regional determination of ventilated lung volume, including its blood and tissue compartments. The advantage of this technique over computed tomography or ventilation scintigraphy is the lack of radiation exposure, and hence its repeatability. Follow up of SLTX patients with this new technique may allow the monitoring of functional and structural developments of grafted lungs with better sensitivity and specificity than PFT.

Female↗

Volumetry of ventilated airspaces by 3He MRI: preliminary results.

RATIONALE AND OBJECTIVES: To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI. METHODS: 3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated. RESULTS: Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,348 +/- 744 mL and mean FRC was 3,422 +/- 817 mL, with the mean difference down to -74 mL (r = 0.9). Comparison on an individual basis confirmed an improvement in the estimation of absolute lung volume. CONCLUSIONS: Volumetry of ventilated lung from 3He MRI shows high correlation and good agreement with the results of pulmonary function tests.

Adult↗

(3)He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes.

MRI with hyperpolarized helium-3 ((3)He) provides high-resolution imaging of ventilated airspaces. The first aim of this (3)He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired (3)He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/alpha = 11 ms/4.2 ms/<10 degrees ). Known amounts of (3)He were inhaled from a microprocessor-controlled delivery device and imaged during single breath-holds. Images were evaluated visually, and scored using a prospectively defined 'defect-index'. Signal-to-noise ratio of the images were correlated with localization, (3)He volumes and static lung volumes. Due to poor image quality studies of two smokers were not eligible for the evaluation. Smokers differed from non-smokers in total number and size of defects: the 'defect-index' of smokers ranged between 0.8 and 6.0 (median = 1.1), that of non-smokers between 0.1 and 0.8 (median = 0.4). Intraindividually, an anteroposterior gradient of signal-to-noise ratio was apparent. Signal-to-noise ratio correlated with the estimated amount of hyperpolarization administered (r = 0. 77), but not with static lung volumes. We conclude that (3)He MRI is a sensitive measure to detect regional abnormalities in the distribution of ventilation in clinically healthy persons with normal pulmonary function tests.

Adult↗