PubMed Health⌕ Search

Biomedical subjects

M Resch

Publications and source records attributed to M Resch.

26 records · Page 2Linked to original sources

Pulsatile non-Newtonian blood flow in three-dimensional carotid bifurcation models: a numerical study of flow phenomena under different bifurcation angles.

Flow and stress patterns in human carotid artery bifurcation models, which differ in the bifurcation angle, are analysed numerically under physiologically relevant flow conditions. The governing Navier-Stokes equations describing pulsatile, three-dimensional flow of an incompressible non-Newtonian fluid are approximated using a pressure correction finite element method, which has been developed recently. The non-Newtonian behaviour of blood is modelled using Casson's relation, based on measured dynamic viscosity. The study concentrates on flow and stress characteristics in the carotid sinus. The results show that the complex flow in the sinus is affected by the angle variation. The magnitude of reversed flow, the extension of the recirculation zone in the outer sinus region and the duration of flow separation during the pulse cycle as well as the resulting wall shear stress are clearly different in the small angle and in the large angle bifurcation. The haemodynamic phenomena, which are important in atherogenesis, are more pronounced in the large angle bifurcation.

Arteriosclerosis↗

Pulsatile non-Newtonian flow characteristics in a three-dimensional human carotid bifurcation model.

Numerical analysis of flow phenomena and wall shear stresses in the human carotid artery bifurcation has been carried out using a three-dimensional geometrical model. The primary aim of this study is the detailed discussion of non-Newtonian flow velocity and wall shear stress during the pulse cycle. A comparison of non-Newtonian and Newtonian results is also presented. The applied non-Newtonian behavior of blood is based on measured dynamic viscosity. In the foreground of discussion are the flow characteristics in the carotid sinus. The investigation shows complex flow patterns especially in the carotid sinus where flow separation occurs at the outer wall throughout the systolic deceleration phase. The changing sign of the velocity near the outer sinus wall results in oscillating shear stress during the pulse cycle. At the outer wall of the sinus at maximum diameter level the shear stress ranges from -1.92 N/m2 to 1.22 N/m2 with a time-averaged value of 0.04 N/m2. At the inner wall of the sinus at maximum diameter level the shear stress range is from 1.16 N/m2 to 4.18 N/m2 with a mean of 1.97 N/m2. The comparison of non-Newtonian and Newtonian results indicates unchanged flow phenomena and rather minor differences in the basic flow characteristics.

Algorithms↗

Numerical flow studies in human carotid artery bifurcations: basic discussion of the geometric factor in atherogenesis.

In this study fluid dynamic variables are analysed numerically in different human carotid artery bifurcation models in order to clarify the geometric factor in carotid bifurcation atherogenesis. The geometric variations describe healthy human carotid bifurcation anatomy and concern the shape of the carotid sinus and the angle between the branches. The flow conditions remain unchanged. The governing Navier--Stokes equations describing incompressible, pulsatile, three-dimensional viscous flow are approximated using a pressure correction finite element procedure which has been developed for time-consuming, three-dimensional, time-dependent viscous flow problems. The study concentrates on flow velocity, on detailed analysis of flow separation and flow recirculation, and on wall shear stress distribution. The results show that the extension and the location of the recirculation zone in the sinus as well as the duration of separated flow during the pulse cycle are affected by the geometrical variations. In view of the significance of the reversed flow zones and of the accompanied low shear regions in atherogenesis the geometry-dependent flow separation characteristics in the sinus is of substantial interest.

Arteriosclerosis↗

Pulsatile non-Newtonian blood flow simulation through a bifurcation with an aneurysm.

Blood flow is analysed by means of computer simulation in an idealized arterial bifurcation model which is pathologically altered by a saccular aneurysm. The theoretical study of the flow pattern and the paths of fluid particles is carried out under pulsatile Newtonian and non-Newtonian flow conditions. The governing equations are solved numerically with the use of the finite element method. The results show the disturbed blood flow in the bifurcation and the relatively low intra-aneurysmal flow circulation. In addition to the study of basic flow patterns in the segment, a comparison of non-Newtonian and Newtonian results is carried out. This comparison proves that for the considered large artery model under physiological flow conditions where the yield number is relatively low there is no essential difference in the results.

Aneurysm↗

[Therapy of proximal trochanteric fractures using elastic round nails].

Stabilising per-and subtrochanteric fractures, especially in elderly patients, by Ender's nails is a slightly invasive and relatively simple method. In our opinion it is the best way of increasing the survival-rate. Dislocation of nails which would cause a reoperation can be avoided by using a wire-cerclage combined with a screw. Fixation of nails in the distal femur is possible without giving up the principle of a "gliding osteosynthesis".

Age Factors↗

[Problems of the stone-free gallbladder, a report on 276 cholecystectomies].

Different kinds of disease of the gallbladder without stones are demonstrated. The indication for cholecystectomy is given by anamnesis, radiological findings and the exact exploration of the adjoining organs. There is made a difference between absolute and relative indications. Among 6,311 cholecystectomies there are 276 gallbladders without stones (4.37%). The results of postoperative controls are reported, more than 76% of the patients are absolutely free, 16% are relatively free of complaints.

Adult↗

[Endoscopic manometry in the common bile duct].

Reproducible results were obtained by endoscopic transpapillary pressure measurements with the help of a constantly perfused catheter. Manometric measurements were performed in 51 patients without any premedication. 14 patients with a normal biliary system were compared with 17 patients after cholecystectomy, 14 patients with stones in the common bile duct and 6 patients after papillotomy. Although there were significant differences in the diameter of the common bile duct in the four groups, only the papillotomized patients demonstrated a distinct change of the pressure in the bile duct. In these patients almost no pressure gradient existed between the biliary ducts and the duodenum. On the other hand, there was an increase in intraluminal pressure in the 2 patients with papillary stenosis. Endoscopic manometric measurements in the common bile duct are indicated to obtain reliable data on stenosis of the papilla duodeni, insufficient papillotomy or recurrent stenosis.

Aged↗