Bedside monitoring of CBF with xenon-CT and a mobile scanner: a novel method in neurointensive care.

Combining previously independently established techniques our objective was to develop and evaluate a method for bedside qualitative assessment of cerebral blood flow in neurointensive care (NICU) patients. The CT-protocol was optimized using phantoms and comparing a mobile CT-scanner (Tomoscan-M, Philips) with two stationary CT scanners. Thirty-two per cent xenon was delivered with standard equipment (Enhancer 3000). Mean cortical flow in volunteers was 48 ml/min/100 g, with the mean vascular territorial flow varying between 45 and 66 ml/min/100 g. The potential clinical usefulness was illustrated in three patients with vasospasm following subarachnoid haemorrhage. Our conclusion is that quantitative bedside measurements of CBF can be repeatedly performed in an easy and safe way in a standard NICU-setting, using xenon-inhalation and a mobile CT-scanner. The method is useful for the decision-making, and is a good example of how the quality of multi-modality monitoring in the NICU can be developed and further diversified.

Adult↗

Breast dosimetry using high-resolution voxel phantoms.

A computer model of X-ray mammography has been developed, which uses quasi-realistic high-resolution voxel phantoms to simulate the breast. The phantoms have 400 microm voxels and simulate the three-dimensional distributions of adipose and fibro-glandular tissues, Cooper's ligaments, ducts and skin and allow the estimation of dose to individual tissues. Calculations of the incident air kerma to mean glandular dose conversion factor, g, were made using a Mo/Mo spectrum at 28 kV for eight phantoms in the thickness range 40-80 mm and of varying glandularity. The values differed from standard tabulations used for breast dosimetry by up to 43%, because of the different spatial distribution of glandular tissue within the breast. To study this further, additional voxel phantoms were constructed, which gave variations of between 9 and 59% compared with standard values. For accurate breast dosimetry, it is therefore very important to take the distribution of glandular tissues into account.

Breast↗

Monte Carlo simulation of a mammographic test phantom.

A test phantom, including a wide range of mammographic tissue equivalent materials and test details, was imaged on a digital mammographic system. In order to quantify the effect of scatter on the contrast obtained for the test details, calculations of the scatter-to-primary ratio (S/P) have been made using a Monte Carlo simulation of the digital mammographic imaging chain, grid and test phantom. The results show that the S/P values corresponding to the imaging conditions used were in the range 0.084-0.126. Calculated and measured pixel values in different regions of the image were compared as a validation of the model and showed excellent agreement. The results indicate the potential of Monte Carlo methods in the image quality-patient dose process optimisation, especially in the assessment of imaging conditions not available on standard mammographic units.

Adipose Tissue↗

Calculation of the properties of digital mammograms using a computer simulation.

A Monte Carlo computer model of mammography has been developed to study and optimise the performance of digital mammographic systems. The program uses high-resolution voxel phantoms to model the breast, which simulate the adipose and fibroglandular tissues, Cooper's ligaments, ducts and skin in three dimensions. The model calculates the dose to each tissue, and also the quantities such as energy imparted to image pixels, noise per image pixel and scatter-to-primary (S/P) ratios. It allows studies of the dependence of image properties on breast structure and on position within the image. The program has been calibrated by calculating and measuring the pixel values and noise for a digital mammographic system. The thicknesses of two components of this system were unknown, and were adjusted to obtain a good agreement between measurement and calculation. The utility of the program is demonstrated with the calculations of the variation of the S/P ratio with and without a grid, and of the image contrast across the image of a 50-mm-thick breast phantom.

Adipose Tissue↗

Influence of the characteristic curve on the clinical image quality of lumbar spine and chest radiographs.

The "European Guidelines on Quality Criteria for Diagnostic Radiographic Images" do not address the choice of the film characteristic (H&D) curve, which is an important parameter for the description of a radiographic screen-film system. The image contrast of clinical lumbar spine and chest radiographs was altered by digital image processing techniques, simulating images with different H&D curves, both steeper and flatter than the original. The manipulated images were printed on film for evaluation. Seven experienced radiologists evaluated the clinical image quality by analysing the fulfilment of the European Image Criteria (ICS) and by visual grading analysis (VGA) of in total 224 lumbar spine and 360 chest images. A parallel study of the effect of the H&D curve has also been made using a theoretical model. The contrast (DeltaOD) of relevant anatomical details was calculated, using a Monte Carlo simulation-model of the complete imaging system including a 3D voxel phantom of a patient. Correlations between the calculated contrast and the radiologists' assessment by VGA were sought. The results of the radiologists' assessment show that the quality in selected regions of lumbar spine and chest images can be significantly improved by the use of films with a steeper H&D curve compared with the standard latitude film. Significant (p<0.05) correlations were found between the VGA results and the calculations of the contrast of transverse processes and trabecular details in the lumbar spine vertebrae, and with the contrast of blood vessels in the retrocardiac area of the chest.

Computer Simulation↗

A study and optimization of lumbar spine X-ray imaging systems.

A Monte Carlo program has been developed that incorporates a voxel phantom of an adult patient in a model of the complete X-ray imaging system, including the anti-scatter grid and screen-film receptor. This allows the realistic estimation of patient dose and the corresponding image (optical density map) for a wide range of equipment configurations. This paper focuses on the application of the program to lumbar spine anteroposterior and lateral screen-film examinations. The program has been applied to study the variation of physical image quality measures and effective dose for changing system parameters such as tube voltage, grid design and screen-film system speed. These variations form the basis for optimization of these system parameters. In our approach to optimization, the best systems are those that can match (or come close to) the calculated image quality measure of systems preferred in a recent European clinical trial, but with lower patient dose. The largest dose savings found were 21% for a 400 speed class system with a grid having a strip density of 40 cm(-1) and a grid ratio of 16. A further dose saving of 13% was possible when a 600 speed class system was employed. The best systems found from the optimization correspond to those recommended by the European Commission guidelines on image quality criteria for diagnostic radiographic images.

Adult↗

Schemes for the optimization of chest radiography using a computer model of the patient and x-ray imaging system.

A computer program has been developed to model chest radiography. It incorporates a voxel phantom of an adult and includes antiscatter grid, radiographic screen, and film. Image quality is quantified by calculating the contrast (deltaOD) and the ideal observer signal-to-noise ratio (SNR(I)) for a number of relevant anatomical details at various positions in the anatomy. Detector noise and system unsharpness are modeled and their influence on image quality is considered. A measure of useful dynamic range is computed and defined as the fraction of the image that is reproduced at an optical density such that the film gradient exceeds a preset value. The effective dose is used as a measure of the radiation risk for the patient. A novel approach to patient dose and image quality optimization has been developed and implemented. It is based on a reference system acknowledged to yield acceptable image quality in a clinical trial. Two optimizations schemes have been studied, the first including the contrast of vessels as measure of image quality and the second scheme using also the signal-to-noise ratio of calcifications. Both schemes make use of our measure of useful dynamic range as a key quantity. A large variety of imaging conditions was simulated by varying the tube voltage, antiscatter device, screen-film system, and maximum optical density in the computed image. It was found that the optical density is crucial in screen-film chest radiography. Significant dose savings (30%-50%) can be accomplished without sacrificing image quality by using low-atomic-number grids with a low grid ratio or an air gap and more sensitive screen-film system. Dose-efficient configurations proposed by the model agree well with the example of good radiographic technique suggested by the European Commission.

Dose-Response Relationship, Radiation↗

Demonstration of correlations between clinical and physical image quality measures in chest and lumbar spine screen-film radiography.

The ability to predict clinical image quality from physical measures is useful for optimization in diagnostic radiology. In this work, clinical and physical assessments of image quality are compared and correlations between the two are derived. Clinical assessment has been made by a group of expert radiologists who evaluated fulfillment of the European image criteria for chest and lumbar spine radiography using two scoring methods: image criteria score (ICS) and visual grading analysis score (VGAS). Physical image quality measures were calculated using a Monte Carlo simulation model of the complete imaging system. This model includes a voxelized male anatomy and was used to calculate contrast and signal-to-noise ratio of various important anatomical details and measures of dynamic range. Correlations between the physical image quality measures on the one hand and the ICS and VGAS on the other were sought. 16 chest and 4 lumbar spine imaging system configurations were compared in frontal projection. A statistically significant correlation with clinical image quality was found in chest posteroanterior radiography for the contrast of blood vessels in the retrocardiac area and a measure of useful dynamic range. In lumbar spine anteroposterior radiography, a similar significant correlation with clinical image quality was found between the contrast and signal-to-noise ratio of the trabecular structures in the L1-L5 vertebrae. The significant correlation shows that clinical image quality can, at least in some cases, be predicted from appropriate measures of physical image quality.

Computer Simulation↗

Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study.

The comparative performance of mammographic X-ray systems that use different anode/filter combinations has been assessed for screen-film and digital imaging. Monte Carlo techniques have been used to calculate average glandular dose as well as contrast and signal-to-noise ratio for imaging two test details. Five anode/filter combinations have been studied to establish the potential for dose saving or image quality improvement. For screen-film mammography, it was found that little benefit is gained by changing from a standard 28 kV molybdenum/molybdenum spectrum for breasts up to 6 cm thick. For thicker breasts, where the tube potential for the standard technique might be increased, 20% improvement in contrast can be achieved without dose penalty using molybdenum/rhodium or rhodium/rhodium spectra, whereas dose savings of more than 50% can be attained whilst maintaining contrast using tungsten/rhodium or rhodium/aluminium spectra. In digital mammography, a molybdenum/molybdenum spectrum delivers the lowest dose for a 2 cm breast, but gives the highest dose for thicker breasts. Tungsten/rhodium or rhodium/aluminium spectra provide the lowest doses at greater thicknesses. It is concluded that for screen-film mammography, molybdenum/molybdenum is the spectrum of choice for all but the thickest or most glandular breasts. In digital mammography, an alternative spectrum is preferable for breasts thicker than 2 cm.

Aluminum↗

Use of the concept of energy imparted in diagnostic radiology.

The concept of energy imparted by ionizing radiation to the matter in a volume is analyzed and methods to determine the energy imparted epsilon to the patient are reviewed, in particular, determinations based on measurements of the air kerma integrated over beam area [the kerma-area-product (KAP)] and calculations needed to derive conversion factors epsilon/KAP. The energy imparted to the image receptor, epsilon rec, including the statistical aspects of the concept, and the effect of epsilon rec on image quality and patient dose are also analysed. Finally, use of the energy imparted to the patient as a risk indicator is discussed.

Humans↗

A search for improved technique factors in paediatric fluoroscopy.

A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assessed for the task of detecting a detail in the image of a patient-simulating phantom, and was expressed in terms of the ideal observer's signal-to-noise ratio (SNR) for static images and in terms of the accumulating rate of the square of SNR for dynamic imaging. The entrance air kerma (or air kerma rate) and the mean absorbed dose (or dose rate) in the phantom quantified radiation detriment. The calculations were made for homogeneous phantoms simulating newborn, 3-, 10- and 15-year-old patients, barium and iodine contrast material details, several x-ray spectra, and for imaging with or without an antiscatter grid. The image receptor was modelled as a CsI x-ray image intensifier (XRII). For the task of detecting low- or moderate-contrast iodine details, the optimal spectrum can be obtained by using an x-ray tube potential near 50 kV and filtering the x-ray beam heavily. The optimal tube potential is near 60 kV for low- or moderate-contrast barium details, and 80-100 kV for high-contrast details. The low-potential spectra above require a high tube load, but this should be acceptable in paediatric fluoroscopy. A reasonable choice of filtration is the use of an additional 0.25 mm Cu, or a suitable K-edge filter. No increase in the optimal tube potential was found as phantom thickness increased. With the constraint of constant low-contrast detail detectability, the mean absorbed doses obtained with the above spectra are approximately 50% lower than those obtained with the reference conditions of 70 kV and 2.7 mm Al filter. For the smallest patient and x-ray field size, not using a grid was slightly more dose-efficient than using a grid, but when the patient size and field size were increased a fibre interspaced grid resulted in lower doses than imaging without a grid. For a 15-year-old patient the mean absorbed doses were up to 40% lower with this grid than without the grid.

Adolescent↗

Sensitivity of coefficients for converting entrance surface dose and kerma-area product to effective dose and energy imparted to the patient.

We investigate the sensitivity of the conversions from entrance surface dose (ESD) or kerma-area product (KAP) to effective dose (E) or to energy imparted to the patient (epsilon) to the likely variations in tube potential, field size, patient size and sex which occur in clinical work. As part of a factorial design study for chest and lumbar spine examinations, the tube potentials were varied to be +/-10% of the typical values for the examinations while field sizes and the positions of the field centres were varied to be representative of values drawn from measurements on patient images. Variation over sex and patient size was based on anthropomorphic phantoms representing males and females of ages 15 years (small adult) and 21 years (reference adult). All the conversion coefficients were estimated using a mathematical phantom programmed with the Monte Carlo code EGS4 for all factor combinations and analysed statistically to derive factor effects. In general, the factors studied behaved independently in the sense that interaction of the physical factors generally gave no more than a 5% variation in a conversion coefficient. Taken together, variation of patient size, sex, field size and field position can lead to significant variation of E/KAP by up to a factor of 2, of E/ESD by up to a factor of 3, of epsilon/KAP by a factor of 1.3 and of epsilon/ESD by up to a factor of 2. While KAP is preferred to determine epsilon, the results show no strong preference of KAP over ESD in determining E. The mean absorbed dose D in the patient obtained by dividing epsilon (determined using KAP) by the patient's mass was found to be the most robust measure of E.

Adolescent↗

The use of carbon fibre material in radiographic cassettes: estimation of the dose and contrast advantages.

A Monte Carlo simulation has been used to estimate the dose and contrast advantages of replacing radiographic cassette fronts fabricated from aluminium with cassette fronts fabricated from low atomic number material (carbon fibre). The simulation used a realistic imaging geometry and calculations were made both with and without an anti-scatter grid. Account was taken of the scatter generated in the cassette front and the effect of beam hardening on primary contrast. Dose and contrast were evaluated for a range of cassette front thicknesses and tube potentials (60-150 kV) as well as for four examinations representative of situations with varying amounts of scatter. The results with an anti-scatter grid show a clear dose and contrast advantage in all cases when an aluminium cassette front is replaced with a low attenuation cassette front. The contrast advantage is dependent upon the examination and is generally greater for imaging bony structures than for imaging soft tissue. If a 1.74 mm aluminium cassette front is compared with a 1.1 mm carbon fibre cassette front, then the dose advantages are 16%, 9%, 8% and 6% and the contrast advantages are 10%, 7%, 4% and 5% for the AP paediatric pelvis examination at 60 kV, the anteroposterior (AP) lumbar spine examination at 80 kV, the lateral lumbar spine examination at 100 kV and the posteroanterior (PA) chest examination at 150 kV, respectively. The results without an anti-scatter grid show an increased dose advantage when a low attenuation cassette front is used, but the contrast advantage is small and in some situations negative.

Aluminum↗

Transmission ionization chambers for measurements of air collision kerma integrated over beam area. Factors limiting the accuracy of calibration.

Kerma-area product meters (KAP meters) are frequently used in diagnostic radiology to measure the integral of air-collision kerma over an area A (integral of A Kc,air dA) perpendicular to the x-ray beam. In this work, a precise method for calibrating a KAP meter to measure integral of A Kc,air dA is described and calibration factors determined for a broad range of tube potentials (40-200 kV). The integral is determined using a large number of TL dosimeters spread over and outside the nominal field area defined as the area within 50% of maximum Kc,air. The method is compared to a simplified calibration method which approximates the integral by multiplying the kerma in the centre of the field by the nominal field area Anom. While the calibration factor using the precise method is independent of field area and distance from the source, that using the simplified method depends on both. This can be accounted for by field inhomogeneities caused by the heel effect, extrafocal radiation and scattered radiation from the KAP meter. The deviations between the calibration factors were as large as +/- 15% for collimator apertures of 5-100 cm2 and distances from the source of 50-160 cm. The uncertainty in the calibration factor using the precise method was carefully evaluated and the expanded relative uncertainty estimated to be +/- 3% with a confidence level of 95%.

Equipment Design↗

Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculations.

We have studied image quality in fluoroscopy, as related to the detectability of low-contrast iodine or acrylic (PMMA) details added to a homogeneous 20 cm thick PMMA phantom, by experimental measurements of the signal-to-noise ratio (SNR) and by Monte Carlo calculation. The agreement between the measured and calculated SNR at equal absorbed dose in the phantom showed that the imaging performance of x-ray image intensifier (XRII) based fluoroscopic systems is well understood and can be mainly accounted for by x-ray attenuation in the phantom and the detail, and by the interaction statistics of primary and secondary (scattered) x-ray quanta in the input phosphor of the XRII. The electronic noise sources in the video chain had only a small effect on the detectability of the details studied here. The optimal x-ray tube potential was 50-60 kV for detecting the low-contrast iodine detail in the phantom, and 70-100 kV for detecting the thin PMMA detail. For the task of detecting the iodine detail the use of a fibre-interspaced antiscatter grid improved the dose-to-information conversion efficiency of the imaging system by a factor of 2.2 as compared to imaging without the grid, and additional filtering of the x-ray beam by 0.25 mm Cu increased the efficiency by a factor of 1.6. Monte Carlo results were further used to estimate the potential of increasing the dose-to-information conversion efficiency by imaging system design changes. For the detection task of a static, low-contrast, low-spatial-frequency iodine contrast material detail embedded in a 20 cm thick soft-tissue phantom, the greatest contributions for further improvement could be achieved by improved antiscatter devices, x-ray spectrum modification, and by decreasing the absorption in the material layers in front of the CsI phosphor of the XRII. Contrary to this, no significant efficiency increase could be obtained by increasing the CsI phosphor coating thickness from the present value of 180 mg cm-2, or by changes in the video chain characteristics. The maximum potential of efficiency improvement is a factor of 6.3 when compared to the reference fluoroscopy system operated at 60 kV with 2.7 mm Al primary beam filtration, and a factor of 3.9 when compared to the reference system at 50 kV with the primary beam filtration added by 0.25 mm Cu.

Fluoroscopy↗

The physical performance of different x-ray contrast agents: calculations using a Monte Carlo model of the imaging chain.

A Monte Carlo computational model of the imaging chain has been used to investigate the performance of x-ray contrast agents with atomic number, Z, 53 < or = Z < or = 90 with respect to physical image quality descriptors (contrast and signal to noise ratio, SNR) and patient mean absorbed dose. Contrast agents of equal molar concentrations were used within a water slab (simulating the patient). The imaging conditions were chosen to represent adult and paediatric examinations. For all tube potentials studied (40-140 kV), the contrast agents with the highest atomic numbers (bismuth and thorium) gave the highest contrast. In analogue screen-film imaging, several other contrast agents could produce a higher image contrast than iodine in a limited range of tube potentials. This advantage could alternatively be effected as a reduced amount of administered contrast agent, or as a reduced mean absorbed dose in the patient. In digital imaging, a lower mean absorbed dose for a constant SNR than that with iodine can be achieved for ranges of tube potentials and contrast agents. Bismuth and thorium yield a lower dose than iodine at all studied tube potentials. Gadolinium and erbium could alternatively be used at a broad range of tube potentials above 90 kV with a dose penalty of only 5-20%.

Adult↗

Shaping X-ray spectra with filters in X-ray diagnostics.

The influence on image contrast, tube load and patient mean absorbed dose of different ways of shaping diagnostic X-ray spectra by placing filters in the beam is derived fro two radiographic models (abdominal screen-film radiography and intra-oral, dental radiography) using a computational model. The filters are compared at either equal tube load (keeping tube potential constant) or equal contrast (adjusting the tube potential with the different filters), but always at equal energy imparted per unit area to the image receptor. Compared at equal tube load and relative to standard aluminum filtration, reductions in the mean absorbed dose in the patient of 15-25% can be achieved using filters of Cu, Ti, W and Au (increasing the tube load by 30-40% compared with standard aluminium filtration). However, contrast is also reduced by 7%. Compared at equal contrast, the dose reductions are smaller, about 10%. Filters of copper are generally recommended, as are filters of aluminium. The use of bandpass filters (K-edge filters) should be restricted to examinations where the need for substantial variation in tube potential from patient to patient is small. The benefit of using thicker filters than those commonly used today (increasing tube load by factors of 1.4-2.0 compared with no added filter) is small as the dose reduction is most rapid for small initial values of added filters, and the increase in tube load increases steadily with increasing filter thickness.

Humans↗

A Monte Carlo program for the calculation of contrast, noise and absorbed dose in diagnostic radiology.

A Monte Carlo computer program has been developed for the simulation of X-ray photon transport in diagnostic X-ray examinations. The simulation takes account of the incident photon energy spectrum and includes a phantom (representing the patient), an anti-scatter grid and an image receptor. The primary objective for developing the program was to study and optimise the design of anti-scatter grids. The program estimates image quality in terms of contrast and signal-to-noise ratio, and radiation risk in terms of mean absorbed dose in the patient. It therefore serves as a tool for the optimisation of the radiographic procedure. A description is given of the program and the variance-reduction techniques used. The computational method was validated by comparison with measurements and other Monte Carlo simulations.

Computer Simulation↗