Publications and source records attributed to M Sandborg.

25 records · Page 2Linked to original sources

A Monte Carlo study of grid performance in diagnostic radiology: task-dependent optimization for digital imaging.

A Monte Carlo computational model has been used to optimize grid design in digital radiography. The optimization strategy involved finding grid designs that, for a constant signal-to-noise ratio, resulted in the lowest mean absorbed dose in the patient. Different examinations were simulated to explore the dependence of the optimal scatter-rejection technique on the imaging situation. A large range of grid designs was studied, including grids with both aluminium and fibre interspaces and covers, and compared to a 20 cm air gap. The results show that the optimal tube potential in each examination does not depend strongly on the scatter-rejection technique. There is a significant dose reduction associated with the use of fibre-interspaced grids, particularly in paediatric radiography. The optimal grid ratio and strip width increase with increasing scattering volume. With increasing strip density, the optimal strip width decreases, and the optimal grid ratio increases. Optimal grid ratios are higher than those used today, particularly for grids with large strip density. It is, however, possible to identify grids of good performance for a range of strip densities and grid ratios provided the strip width is selected accordingly. The computational method has been validated by comparison with measurements with a caesium iodide image receptor.

Algorithms↗

Monte Carlo study of grid performance in diagnostic radiology: task dependent optimization for screen-film imaging.

An optimization of anti-scatter grid design using Monte Carlo techniques in diagnostic radiology is presented. The criterion for optimization was to find the combinations of the grid parameters (lead strip width, grid ratio and strip density) and tube potential which result in the lowest mean absorbed dose in the patient at fixed image contrast. The optimization was performed in three irradiation geometries, representing different scattering conditions (paediatric examinations, and two adult lumbar spine examinations) and was restricted to grids using fibre materials in covers and interspaces. Grid designs currently available were studied, as were designs which use thinner strips (< 30 microns) and higher grid ratios (> 18). It was found that grids with widely different strip densities (strips cm-1) and grid ratios can have good performance provided that they are used with appropriate strip width and tube potential. With increasing amounts of scatter, the optimal grid requires thicker strips and higher grid ratios. Increasing the strip density and using thinner strips and higher grid ratios are generally required. Grids with low strip density (25 strips cm-1) were found to be less sensitive to alterations in strip width. Optimal grids for paediatric radiology require thinner strips (10-20 microns) than those in currently available grids. Grids on the market are best suited for examinations of the adult body in anteroposterior (AP) view. In the adult lateral view, representing the largest scattering volume, higher grid ratios (> 18) than those in existing grids would be optimal. Examples of good grid designs are given for each examination.

Adult↗

Selection of anti-scatter grids for different imaging tasks: the advantage of low atomic number cover and interspace materials.

A Monte Carlo computer program has been developed for the study of anti-scatter grids used in diagnostic radiology. The program estimates the scatter from soft tissue phantoms representative of either adult or paediatric examinations and uses dose increase, signal-to-noise ratio improvement and contrast improvement factors to study grid performance. It has been used to quantify the advantage of replacing grids with aluminium covers and interspaces by grids using materials of low atomic number for these components. Two approaches are used. First, the aluminium and low atomic number alternatives are compared for five grid ratios at fixed strip density and width and for tube potentials of 50, 70, 100 and 150 kV. Second, 44 commercially available grids are compared for three different imaging situations (lumbar spine, chest and paediatric). The results demonstrate that grids made with carbon fibre cover and cotton fibre interspace result in greater improvements in contrast and signal-to-noise ratio, and lower dose increase factors, than do grids made with aluminium. The dose reduction varies with irradiation conditions and is generally larger at lower tube potentials, higher grid ratios and lower strip densities. A typical reduction in mean absorbed dose in the patient is 30% in an adult lumbar spine (AP view) at 70 kV with a grid with 36 strips per centimetre and ratio 12.

Adult↗

Monte Carlo study of grid performance in diagnostic radiology: factors which affect the selection of tube potential and grid ratio.

A Monte Carlo computational model has been developed for the study of the performance of anti-scatter grids in diagnostic radiology. It is used here to estimate the scatter in the image plane from soft tissue phantoms (representing the patient) and to calculate image contrast and the mean absorbed dose in the phantom. Different scattering conditions, representative of various examinations, have been investigated: adult lumbar spine; small field radiography and fluoroscopy; adult chest and paediatric pelvis and chest. For each scattering condition, the combinations of tube potential and grid ratio have been found which, for a well designed grid, result in the lowest mean absorbed dose in the phantom for a fixed contrast level. In examinations which generate large amounts of scatter, the use of high grid ratios in combination with high tube potentials is favourable with regard to both mean absorbed dose in the phantom and tube charge. When less scatter is generated, either the grid ratio or the tube potential can be varied to achieve the desired contrast level. High grid ratios require shorter exposure times, but need careful alignment in the beam to prevent primary radiation cut-off. It is shown that the air gap technique can be used to reduce patient dose in examinations with small amounts of scatter, but in combinations with a lower tube potential than when a grid is used.

Adult↗

Conversion factors between energy imparted to the patient and air collision kerma integrated over beam area in pediatric radiology.

Conversion factors between the energy imparted to the patient in pediatric radiography and air collision kerma integrated over beam area are presented. The values have been derived from Monte Carlo calculations in soft tissue phantoms and extend results published earlier to cover children from early infancy to the age of 15 years. Variations related to phantom size as well as to focus-phantom distance, radiation field size, orientation of view (a.p., lateral), tube potential, and beam filtration are given. We show that the conversion factor increases with increasing half-value layer of the X-ray beam and the anterioposterior width of the simulated child. Increasing the focus-phantom distance increases the conversion factor, while increasing the field size decreases the factors due to more scattered radiation escaping laterally from the phantom.

Adolescent↗

Influence of scattered radiation and tube potential on radiographic contrast: comparison of two different dental X-ray films.

The fundamental concept in image quality of contrast has been analysed in terms of its elements; film, radiation and object contrast, and the theoretical formula to describe their interrelationship have been evaluated. Experiments were designed to investigate the dependence of radiographic contrast on the kV, the type of generator and dental film used (D and E speed). An ivory wedge was used as the object, both alone and within a polymethyl methacrylate phantom as scattering medium. Precise definition and control of the X-ray generators were achieved by means of measurements of the primary X-ray spectra using a Compton spectrometer. D speed was found to have higher film contrast than E speed when compared at the same optical density, due to its lower base and fog and lower level of saturation in these experiments. On the other hand, E speed was found to have wider latitude. The experimental object was reproduced with the highest radiographic contrast using D-speed film and, with a given type of generator, this increased when the kV was decreased. While no difference in scatter/primary ratios was observed using the two different films, a weak dependence on kV in the range from 36 to 77 kV was found and confirmed by Monte Carlo calculations. The results indicate that the D and E speed films used had equal energy absorption properties; the difference in radiographic performance is due to their different film characteristics. The importance of controlling the physical parameters (photon energy spectrum, base and fog and optical density level) when comparing image qualities is clearly demonstrated.

Radiography, Dental↗

Microbeam radiation therapy.

It is proposed to carry out radiotherapy and radiosurgery for brain lesions by crossfiring an array of parallel, closely spaced microbeams of synchrotron-generated x rays several times through an isocentric target, each microbeam in the array having an approximately 25-microns-wide adjustable-height rectangular cross section. The following inferences from the known tissue sparing of 22-MeV deuteron microbeams in the mouse brain and the following exemplary Monte Carlo computations indicate that endothelial cells in the brain that are lethally irradiated by any microbeam in an array of adequately spaced microbeams outside an isocentric target will be replaced by endothelial cells regenerated from microscopically contiguous, minimally irradiated endothelium in intermicrobeam segments of brain vasculature. Endothelial regeneration will prevent necrosis of the nontargeted parenchymal tissue. However, neoplastic and/or nonneoplastic targeted tissues at the isocenter will be so severely depleted of potentially mitotic endothelial and parenchymal cells by multiple overlapping microbeams that necrosis will ensue. The Monte Carlo computations simulate microbeam irradiations of a 16-cm diameter, 16-cm-long cylindrical human head phantom using 50-, 100-, and 150-keV monochromatic x rays.

Brain Neoplasms↗